Hatco SGCP-36 Installation Manual

Register Online!
hatcocorp.com
WARNING
ADVERTENCIA
AVERTISSEMENT
S'inscrire en ligne!
(voir page 12)
Sneeze Guards
Pare-haleine
SGPT, SGCP, and SGEN Series/Série
Installation and Operating Manual
Manuel d'installation et d'utilisation
P/N 07.04.718.00
Do not operate this equipment unless you have read and understood the contents of this manual! Failure to follow the instructions contained in this manual may result in serious injury or death. This manual contains important safety information concerning the maintenance, use, and operation of this product. If you’re unable to understand the contents of this manual, please bring it to the attention of your supervisor. Keep this manual in a safe location for future reference.
English = p 2
No opere este equipo al menos que haya leído y comprendido el contenido de este manual! Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte. Este manual contiene importante información sobre seguridad concerniente al mantenimiento, uso y operación de este producto. Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor. Almacenar este manual en una localización segura para la referencia futura.
Ne pas utiliser cet équipement sans avoir lu et compris le contenu de ce manuel ! Le non-respect des instructions contenues dans ce manuel peut entraîner de graves blessures ou la mort. Ce manuel contient des informations importantes concernant l'entretien, l'utilisation et le fonctionnement de ce produit. Si vous ne comprenez pas le contenu de ce manuel, veuillez le signaler à votre supérieur. Conservez ce manuel dans un endroit sûr pour pouvoir vous y référer plus tard.
Français = p 12
© 2015 Hatco Corporation
NOTICE
CAUTION
WARNING
24 Hour 7 Day Parts and Service Assistance available in the United States and Canada by calling 800-558-0607.
CONTENTS
English
Important Owner Information ..............................................2
Introduction...........................................................................2
Important Safety Information...............................................3
Model Designation................................................................3
Model Description.................................................................4
Specifications........................................................................5
Dimensions ..........................................................................5
Installation.............................................................................6
General ................................................................................6
SGPT Model Installation ......................................................6
SGCP Model Installation......................................................7
SGEN Model Installation......................................................8
IMPORTANT OWNER INFORMATION
Record the model number, serial number, voltage, and purchase date of the unit in the spaces below (specification label located on the post). Please have this information available when calling Hatco for service assistance.
Model No. ________________________________________
Serial No. ________________________________________
Voltage __________________________________________
Date of Purchase __________________________________
Maintenance ..........................................................................9
General ................................................................................9
Daily Cleaning......................................................................9
Limited Warranty.................................................................10
Addendum ...........................................................................11
Authorized Parts Distributors............................Back Cover
Business Hours: 7:00
Telephone: 800-558-0607; 414-671-6350
E-mail: partsandservice@hatcocorp.com
Fax: 800-690-2966 (Parts and Service)
AM to 5:00 PM Central Standard Time (CST)
(Summer Hours: June to September
AM to 5:00 PM CST Monday–Thursday
7:00 7:00
AM to 4:00 PM CST Friday)
414-671-3976 (International)
Register your unit!
Completing online warranty registration will prevent delay in obtaining warranty coverage. Access the Hatco website at www.hatcocorp.com, select the Parts & Service pull-down menu, and click on “Warranty Registration”.
INTRODUCTION
Enhance and protect food products simultaneously with Hatco Sneeze Guards. Ideal for buffet lines and serving stations, the Sneeze Guards guarantee resilient functionality in a stylish design, allowing you to safeguard your food while displaying it clearly to customers.
Sneeze Guards are products of extensive research and field testing. The materials used were selected for maximum durability, attractive appearance, and optimum performance. Every unit is inspected thoroughly prior to shipment.
This manual provides installation and safety instructions for Sneeze Guards. Hatco recommends all installation and safety instructions appearing in this manual be read prior to installation of the unit.
Additional information can be found by visiting our web site at www.hatcocorp.com.
Safety information that appears in this manual is identified by the following signal word panels:
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to personal injury.
2
Form No. SGM-0815
English
NOTICE
NOTICE
CAUTION
S G X X - X X
Sneeze Guard
PT = Portable
CP = Countertop Post
EN = Enclosure
Width (in inches)
IMPORTANT SAFETY INFORMATION
Locate unit in an area that is convenient for use. Location should be level to prevent unit from falling or moving accidentally.
DO NOT submerge or saturate with water. Unit is not waterproof.
Do not steam clean or use excessive water on unit. This unit is not “jet-proof” construction. Do not use jet-
clean spray to clean unit. This unit has no “user-serviceable” parts. If service is
required on this unit, contact an Authorized Hatco Service Agent or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966; or International fax 414-671-3976.
Use non-abrasive cleaners and cloths only. Abrasive cleaners and cloths could scratch finish of unit, marring its appearance and making it susceptible to soil accumulation.
Clean unit daily to avoid malfunctions and maintain sanitary operation.
Do not use harsh chemicals such as bleach, cleaners containing bleach, or oven cleaners to clean unit.
NSF Requirements
SGPT and SGCP models: The vertical distance between the finished floor and the bottom leading edge of a food shield must be 52″ (1321 mm) or less.
SGPT and SGCP models: The horizontal distance between the front of countertop equipment and the bottom leading edge of a food shield shall be 7″ (178 mm) or more.
Form No. SGM-0815
MODEL DESIGNATION
3
MODEL DESCRIPTION
Height Adjustment Knobs
Height Adjustment Knobs
English
All Models
Enhance and protect food products simultaneously with Hatco Sneeze Guards. Ideal for buffet lines and serving stations, the Sneeze Guards guarantee resilient functionality in a stylish design, allowing you to safeguard your food while displaying it clearly to customers. Hatco sneeze guards meet NSF standards.
SGPT Model
The SGPT model is a portable sneeze guard with an adjustable height.
Model SGPT
SGCP Models
The SGCP model is mounted to a countertop with an adjustable height.
Model SGCP
SGEN Models
The SGEN model is mounted to the countertop and offers protection on three sides and overhead.
Model SGEN
4
Form No. SGM-0815
English
SGEN Models
SGCP Models
25-1/4″–61-1/4″ (642–1556 mm)*
18″ (457 mm)
22″ (559 mm)
18-9/16″–54-9/16″*
(472–1386 mm)
21-5/8″–57-5/8″*
(550–1464 mm)
SGPT Models
22″–58″ (559–1473 mm)*
16-5/16″ (414 mm)
19″ (482 mm)
16-7/16″–52-7/16″*
(418–1332 mm)
19-1/2″–55-1/2″*
(495–1410 mm)
25-1/4″–61-1/4″ (642–1556 mm)*
20-5/16″ (516 mm)
22″ (559 mm)
21-5/8″–57-5/8″*
(550–1464 mm)
20-1/8″–56-1/8″*
(511–1426 mm)
18-1/2″ (470 mm)
13-3/16″ (335 mm)
20-3/4″–25-7/8″
(526–657 mm)
19-3/16″–24-5/16″
(487–618 mm)
60°
60°
* Units are sold in increments of 6″ (152 mm) widths. Add the following to the smallest measurement in the range to determine each model’s specific width dimensions:
SGPT-24, SGCP-24, and SGEN-22 models add 0″ (0 mm) SGPT-30, SGCP-30, and SGEN-28 models add 6″ (152 mm) SGPT-36, SGCP-36, and SGEN-34 models add 12″ (305 mm) SGPT-42, SGCP-42, and SGEN-40 models add 18″ (457 mm) SGPT-48, SGCP-48, and SGEN-46 models add 24″ (610 mm) SGPT-54, SGCP-54, and SGEN-52 models add 30″ (762 mm) SGPT-60, SGCP-60, and SGEN-58 models add 36″ (914 mm)
13-1/2″–18-1/2″ (345–470 mm)
12″–17-1/4″ (307–438 mm)
Dimensions
SPECIFICATIONS
Form No. SGM-0815
5
INSTALLATION
Mounting Bolt
Angle Adjustment Pins
Knob
Glass Mounting
Bracket
Angle Adju stme nt
Spacer
Short Knob
Long
Knob
Base
Support
Base Support Screw
Post Screw
Sneeze Guard Mount
Post
Glass
Bushing
Knob
Base Plug
Side Glass Clamp
Glass Bushing
Leg
Leg Plug
Leg Plug
Screw
Base Plug Screw
English
General
Sneeze Guards are shipped with some components pre­assembled. Care should be taken when unpacking the shipping carton to avoid damage to unit and components enclosed.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the IMPORTANT OWNER INFORMATION section for details.
SGPT Model Installation
NOTE: Remove tape and protective packaging from the
surfaces of the unit.
1. Secure the base support to the bottom channel of the two legs using the supplied screws.
• The base support can be installed on either side of leg.
• Remove the base plugs and install on opposite side, if necessary.
2. Secure the two posts to the base using the supplied screws.
• The posts can be installed on middle or end of leg.
• Remove the leg plugs and install on opposite side, if necessary.
3. Slide the side glass clamp then the sneeze guard mount onto each post.
4. Slide the angle adjustment pins through the spacer and into the sneeze guard mount holes. Repeat on opposite post.
5. Slide the glass mounting bracket through the angle adjustment pins. Make sure both brackets are inserted into the pins the same way to ensure both sides are angled properly for a correct fit. The unit is designed for a 60° angle.
6. Secure the glass mounting bracket into place by tightening the knob into the post.
7. Secure the top glass sneeze guard. a. Insert the mounting bolt through the glass sneeze guard. b. Place a glass bushing between the glass sneeze guard
and the glass mounting bracket.
c. Screw the mounting bolt into the glass mounting bracket.
d. Repeat on three remaining glass sneeze guard holes.
8. Move the sneeze guard mounts to the desired position and secure to the post using the knob. The bottom edge of the top glass must be 52″ (1321 mm) or less above floor.
9. Secure the side glass to the outside of each post. a. Tighten the short knob through the glass and into the
sneeze guard mount towards the top.
b. Place a glass bushing between side glass and post.
c. Hold the side glass clamp onto the post.
d. Tighten the long knob into the bottom hole through the
glass bushing and into the clamp.
e. Repeat this step on the opposite end.
10. Place the unit in the desired location.
SGPT Model Installation
6
Form No. SGM-0815
English
Mounting Bolt
Angle Adjustment Pins
Short Knob
Long Knob
Sneeze Guard Mount
Knob
Glass
Mounting
Bracket
Angle
Adjustment
Spacer
Mounting Cover
Glass
Bushing
Knob
Countertop Mounting
Screw
Post
Side Glass Clamp
INSTALLATION
SGCP Model Installation
NOTE: Remove tape and protective packaging from the
surfaces of the unit.
1. Slide the mounting cover, side glass clamp, then the sneeze guard mounts onto each post.
2. Slide the angle adjustment pins through the spacer and into the sneeze guard mount holes. Repeat on opposite post.
3. Slide the glass mounting bracket through the angle adjustment pins. Make sure both sides are inserted into the pins the same way to ensure both sides are angled properly for a correct fit. The unit is designed for a 60° angle.
4. Secure the glass mounting bracket into place by tightening the knob into the post.
5. Secure the top glass sneeze guard. a. Insert the mounting bolt through the glass sneeze guard. b. Place a glass bushing between the glass sneeze guard
and the glass mounting bracket. c. Screw the mounting bolt into the glass mounting bracket. d. Repeat on the three remaining glass sneeze guard
holes.
6. Move the sneeze guard mounts to the desired position and secure to the post using the knob. The bottom edge of the top glass must be 52″ (1321 mm) or less above floor.
7. Place the posts in the desired location and secure the legs into the countertop.
• Move the mounting covers to access the mounting holes.
• Use the “Mounting Template” located in the ADDENDUM section at the end of this manual.
8. Secure the side glass to the outside of each post. a. Tighten the short knob into the top hole. b. Place a glass bushing between the side glass and the
post.
c. Hold the side glass clamp onto the post.
d. Tighten the long knob into the bottom hole through the
glass bushing and into the post.
e. Repeat this step on the opposite end.
Form No. SGM-0815
SGCP Model Installation
7
INSTALLATION
Mounting Nut
Mounting Nut
Glass Bushing
Glass Mount
Mounting Bolt
Countertop Mounting Screw
Mounting Cover
Mounting Bolt
Glass Bushing
Glass Clamp
English
SGEN Model Installation
1. Place each post in the desired location and secure the legs into the countertop.
• Move the mounting covers to access the mounting holes.
• Use the “Mounting Template” located in the ADDENDUM section at the end of this manual.
2. Secure the back glass to the outside of each post. a. Insert the mounting bolt through post. b. Place a glass mount then a glass bushing onto the bolt. c. Slide the glass onto the bolt and secure using nut. d. Repeat on the three remaining back glass holes.
3. Secure the side glass to the outside of each post. a. Place a glass bushing between the side glass and the
post. b. Hold the side glass clamp onto the post. c. Tighten the bolt into the clamp through the top hole of
side glass. d. Repeat on the three remaining side glass holes. e. Repeat this step on the opposite end.
4. Secure the top glass to the top of each post. a. Insert the mounting bolt through post from underneath. b. Place a glass mount and glass bushing onto the bolt.
c. Slide the glass onto the bolt and secure using nut.
d. Repeat on the three remaining top glass holes.
SGEN Model Installation
8
Form No. SGM-0815