Do not operate this equipment unless you
have read and understood the contents of
this manual! Failure to follow the
instructions contained in this manual may
result in serious injury or death. This
manual contains important safety
information concerning the maintenance,
use, and operation of this product. If
you’re unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
English = p 2
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en este
manual puede resultar en un serio lesión
o muerte. Este manual contiene
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted no
puede entender el contenido de este
manual por favor pregunte a su
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel !
Le non-respect des instructions
contenues dans ce manuel peut entraîner
de graves blessures ou la mort. Ce
manuel contient des informations
importantes concernant l'entretien,
l'utilisation et le fonctionnement de ce
produit. Si vous ne comprenez pas le
contenu de ce manuel, veuillez le signaler
à votre supérieur. Conservez ce manuel
dans un endroit sûr pour pouvoir vous y
référer plus tard.
General ................................................................................6
SGPT Model Installation ......................................................6
SGCP Model Installation......................................................7
SGEN Model Installation......................................................8
IMPORTANT OWNER INFORMATION
Record the model number, serial number, voltage, and purchase
date of the unit in the spaces below (specification label located
on the post). Please have this information available when calling
Hatco for service assistance.
Model No. ________________________________________
Serial No. ________________________________________
Voltage __________________________________________
Date of Purchase __________________________________
Authorized Parts Distributors............................Back Cover
Business
Hours:7:00
Telephone: 800-558-0607; 414-671-6350
E-mail:partsandservice@hatcocorp.com
Fax:800-690-2966 (Parts and Service)
AM to 5:00 PM Central Standard Time (CST)
(Summer Hours: June to September—
AM to 5:00 PM CST Monday–Thursday
7:00
7:00
AM to 4:00 PM CST Friday)
414-671-3976 (International)
Register your unit!
Completing online warranty registration will prevent delay in
obtaining warranty coverage. Access the Hatco website at
www.hatcocorp.com, select the Parts & Service pull-down
menu, and click on “Warranty Registration”.
INTRODUCTION
Enhance and protect food products simultaneously with Hatco
Sneeze Guards. Ideal for buffet lines and serving stations, the
Sneeze Guards guarantee resilient functionality in a stylish
design, allowing you to safeguard your food while displaying it
clearly to customers.
Sneeze Guards are products of extensive research and field
testing. The materials used were selected for maximum
durability, attractive appearance, and optimum performance.
Every unit is inspected thoroughly prior to shipment.
This manual provides installation and safety instructions for
Sneeze Guards. Hatco recommends all installation and safety
instructions appearing in this manual be read prior to installation
of the unit.
Additional information can be found by visiting our web site at
www.hatcocorp.com.
Safety information that appears in this manual is identified by
the following signal word panels:
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to
personal injury.
2
Form No. SGM-0815
English
NOTICE
NOTICE
CAUTION
S G X X - X X
Sneeze Guard
PT = Portable
CP = Countertop Post
EN = Enclosure
Width (in inches)
IMPORTANT SAFETY INFORMATION
Locate unit in an area that is convenient for use. Location
should be level to prevent unit from falling or moving
accidentally.
DO NOT submerge or saturate with water. Unit is not
waterproof.
Do not steam clean or use excessive water on unit.
This unit is not “jet-proof” construction. Do not use jet-
clean spray to clean unit.
This unit has no “user-serviceable” parts. If service is
required on this unit, contact an Authorized Hatco Service
Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350; fax 800-690-2966; or
International fax 414-671-3976.
Use non-abrasive cleaners and cloths only. Abrasive
cleaners and cloths could scratch finish of unit, marring its
appearance and making it susceptible to soil accumulation.
Clean unit daily to avoid malfunctions and maintain
sanitary operation.
Do not use harsh chemicals such as bleach, cleaners
containing bleach, or oven cleaners to clean unit.
NSF Requirements
SGPT and SGCP models: The vertical distance between the
finished floor and the bottom leading edge of a food shield
must be 52″ (1321 mm) or less.
SGPT and SGCP models: The horizontal distance between the
front of countertop equipment and the bottom leading edge of
a food shield shall be 7″ (178 mm) or more.
Form No. SGM-0815
MODEL DESIGNATION
3
MODEL DESCRIPTION
Height
Adjustment
Knobs
Height
Adjustment
Knobs
English
All Models
Enhance and protect food products simultaneously with Hatco
Sneeze Guards. Ideal for buffet lines and serving stations, the
Sneeze Guards guarantee resilient functionality in a stylish
design, allowing you to safeguard your food while displaying it
clearly to customers. Hatco sneeze guards meet NSF
standards.
SGPT Model
The SGPT model is a portable sneeze guard with an adjustable
height.
Model SGPT
SGCP Models
The SGCP model is mounted to a countertop with an adjustable
height.
Model SGCP
SGEN Models
The SGEN model is mounted to the countertop and offers
protection on three sides and overhead.
Model SGEN
4
Form No. SGM-0815
English
SGEN Models
SGCP Models
25-1/4″–61-1/4″ (642–1556 mm)*
18″ (457 mm)
22″
(559 mm)
18-9/16″–54-9/16″*
(472–1386 mm)
21-5/8″–57-5/8″*
(550–1464 mm)
SGPT Models
22″–58″ (559–1473 mm)*
16-5/16″ (414 mm)
19″
(482 mm)
16-7/16″–52-7/16″*
(418–1332 mm)
19-1/2″–55-1/2″*
(495–1410 mm)
25-1/4″–61-1/4″ (642–1556 mm)*
20-5/16″ (516 mm)
22″
(559 mm)
21-5/8″–57-5/8″*
(550–1464 mm)
20-1/8″–56-1/8″*
(511–1426 mm)
18-1/2″ (470 mm)
13-3/16″ (335 mm)
20-3/4″–25-7/8″
(526–657 mm)
19-3/16″–24-5/16″
(487–618 mm)
60°
60°
* Units are sold in increments of 6″ (152 mm) widths.
Add the following to the smallest measurement in the range to determine each model’s specific width dimensions:
SGPT-24, SGCP-24, and SGEN-22 models add 0″ (0 mm)
SGPT-30, SGCP-30, and SGEN-28 models add 6″ (152 mm)
SGPT-36, SGCP-36, and SGEN-34 models add 12″ (305 mm)
SGPT-42, SGCP-42, and SGEN-40 models add 18″ (457 mm)
SGPT-48, SGCP-48, and SGEN-46 models add 24″ (610 mm)
SGPT-54, SGCP-54, and SGEN-52 models add 30″ (762 mm)
SGPT-60, SGCP-60, and SGEN-58 models add 36″ (914 mm)
13-1/2″–18-1/2″
(345–470 mm)
12″–17-1/4″
(307–438 mm)
Dimensions
SPECIFICATIONS
Form No. SGM-0815
5
INSTALLATION
Mounting Bolt
Angle Adjustment
Pins
Knob
Glass Mounting
Bracket
Angle Adju stme nt
Spacer
Short
Knob
Long
Knob
Base
Support
Base Support Screw
Post Screw
Sneeze Guard
Mount
Post
Glass
Bushing
Knob
Base
Plug
Side
Glass
Clamp
Glass
Bushing
Leg
Leg Plug
Leg Plug
Screw
Base Plug Screw
English
General
Sneeze Guards are shipped with some components preassembled. Care should be taken when unpacking the shipping
carton to avoid damage to unit and components enclosed.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
SGPT Model Installation
NOTE: Remove tape and protective packaging from the
surfaces of the unit.
1. Secure the base support to the bottom channel of the two
legs using the supplied screws.
• The base support can be installed on either side of leg.
• Remove the base plugs and install on opposite side, if
necessary.
2. Secure the two posts to the base using the supplied screws.
• The posts can be installed on middle or end of leg.
• Remove the leg plugs and install on opposite side, if
necessary.
3. Slide the side glass clamp then the sneeze guard mount
onto each post.
4. Slide the angle adjustment pins through the spacer and into
the sneeze guard mount holes. Repeat on opposite post.
5. Slide the glass mounting bracket through the angle
adjustment pins. Make sure both brackets are inserted into
the pins the same way to ensure both sides are angled
properly for a correct fit. The unit is designed for a 60° angle.
6. Secure the glass mounting bracket into place by tightening
the knob into the post.
7. Secure the top glass sneeze guard.
a. Insert the mounting bolt through the glass sneeze guard.
b. Place a glass bushing between the glass sneeze guard
and the glass mounting bracket.
c. Screw the mounting bolt into the glass mounting bracket.
d. Repeat on three remaining glass sneeze guard holes.
8. Move the sneeze guard mounts to the desired position and
secure to the post using the knob. The bottom edge of the
top glass must be 52″ (1321 mm) or less above floor.
9. Secure the side glass to the outside of each post.
a. Tighten the short knob through the glass and into the
sneeze guard mount towards the top.
b. Place a glass bushing between side glass and post.
c. Hold the side glass clamp onto the post.
d. Tighten the long knob into the bottom hole through the
glass bushing and into the clamp.
e. Repeat this step on the opposite end.
10. Place the unit in the desired location.
SGPT Model Installation
6
Form No. SGM-0815
English
Mounting Bolt
Angle Adjustment
Pins
Short
Knob
Long
Knob
Sneeze Guard
Mount
Knob
Glass
Mounting
Bracket
Angle
Adjustment
Spacer
Mounting Cover
Glass
Bushing
Knob
Countertop Mounting
Screw
Post
Side
Glass
Clamp
INSTALLATION
SGCP Model Installation
NOTE: Remove tape and protective packaging from the
surfaces of the unit.
1. Slide the mounting cover, side glass clamp, then the sneeze
guard mounts onto each post.
2. Slide the angle adjustment pins through the spacer and into
the sneeze guard mount holes. Repeat on opposite post.
3. Slide the glass mounting bracket through the angle
adjustment pins. Make sure both sides are inserted into the
pins the same way to ensure both sides are angled properly
for a correct fit. The unit is designed for a 60° angle.
4. Secure the glass mounting bracket into place by tightening
the knob into the post.
5. Secure the top glass sneeze guard.
a. Insert the mounting bolt through the glass sneeze guard.
b. Place a glass bushing between the glass sneeze guard
and the glass mounting bracket.
c. Screw the mounting bolt into the glass mounting bracket.
d. Repeat on the three remaining glass sneeze guard
holes.
6. Move the sneeze guard mounts to the desired position and
secure to the post using the knob. The bottom edge of the
top glass must be 52″ (1321 mm) or less above floor.
7. Place the posts in the desired location and secure the legs
into the countertop.
• Move the mounting covers to access the mounting holes.
• Use the “Mounting Template” located in the ADDENDUM
section at the end of this manual.
8. Secure the side glass to the outside of each post.
a. Tighten the short knob into the top hole.
b. Place a glass bushing between the side glass and the
post.
c. Hold the side glass clamp onto the post.
d. Tighten the long knob into the bottom hole through the
glass bushing and into the post.
e. Repeat this step on the opposite end.
Form No. SGM-0815
SGCP Model Installation
7
INSTALLATION
Mounting Nut
Mounting Nut
Glass Bushing
Glass Mount
Mounting
Bolt
Countertop
Mounting
Screw
Mounting
Cover
Mounting
Bolt
Glass Bushing
Glass
Clamp
English
SGEN Model Installation
1. Place each post in the desired location and secure the legs
into the countertop.
• Move the mounting covers to access the mounting
holes.
• Use the “Mounting Template” located in the ADDENDUM
section at the end of this manual.
2. Secure the back glass to the outside of each post.
a. Insert the mounting bolt through post.
b. Place a glass mount then a glass bushing onto the bolt.
c. Slide the glass onto the bolt and secure using nut.
d. Repeat on the three remaining back glass holes.
3. Secure the side glass to the outside of each post.
a. Place a glass bushing between the side glass and the
post.
b. Hold the side glass clamp onto the post.
c. Tighten the bolt into the clamp through the top hole of
side glass.
d. Repeat on the three remaining side glass holes.
e. Repeat this step on the opposite end.
4. Secure the top glass to the top of each post.
a. Insert the mounting bolt through post from underneath.
b. Place a glass mount and glass bushing onto the bolt.
c. Slide the glass onto the bolt and secure using nut.
d. Repeat on the three remaining top glass holes.
SGEN Model Installation
8
Form No. SGM-0815