Hatco PMG-60, PMG-100, PMG-200 General Manual

POWERMITE
Models PMG-60, PMG-100, PMG-200
The Hatco Powermite® Gas Booster Water Heater provides 180° F (82° C) sanitizing hot water and long life dependability. Designed to fit under the dishtable, near the dishwasher, minimizes the heat loss that can occur when heaters are installed in a remote location.
FLEXIBILITY
All models can operate on either natural or propane gas and feature a burner system that utilizes both primary and secondary air for consistent ignition.
PMG-60… for single tank, door-type machines. It has 58,000 BTU heating capacity with a storage capacity of 3.2 gallons (12 liters) and has an output equivalent to approximately
13.5kW. This unit can naturally and safely vent directly into the room. Consult local codes for venting requirements. The PMG-60 can increase the temperature of 135 gallons/hour (511 liter/hr) by 40° F (22° C).
PMG-100… for 2-tank, conveyor machines. It has 105,000 BTU heating capacity with a storage capacity of 5 gallons (19 liters) and has an output equivalent to approximately 24kW. The PMG-100 can increase the temperature of 241 gallons/hour (912 liter/hr) by 40° F (22° C).
PMG-200… for large, conveyor-type dishwashing operations. It has 195,000 BTU heating capacity with a storage capacity of 5 gallons (19 liters) and has an output equivalent to approximately 45kW. The PMG-200 can increase the temperature of 452 gallons/hour (1711 liter/hr) by 40° F (22° C).
Models PMG-100 and -200 use a forced draft system with a 4" (102 mm) diameter adapter provided to allow the installer to hook up the exhaust venting to meet regulatory and local codes.
QUALITY
The following features assure the best performance for years to come:
Stainless steel tanks.
Stainless steel front and top, with powdercoat
sides and back (stainless steel body available).
Finned tube copper heat exchanger.
Spark to light with standing pilot.
Eight blade type burners in the PMG-60, three
tube type burners in the PMG-100, six tube type burners in the PMG-200.
Temperature/pressure relief valve.
Pressure reducing valve.
Two temperature/pressure gauges.
Low-water cut-off.
Blended phosphate water treatment system.
Shock absorber.
ITEM#
®
AS BOOSTER WATER HEATERS
G
odel PMG-60 with optional
M Stainless Steel Body and Base and PMGH-60 Exhaust
ood
H
Model PMG-200
odel PMG-100
M
BOOSTER SIZING
WaterTemperature Recovery Table in GPH (LPH) and °F (°C)
Input
MBH (
Model
PMG-60 58 181 ( 685) 135 ( 511) 108 ( 409) 90 ( 341) 77 (292) PMG-100 105 321 (1215) 241 ( 912) 193 ( 731) 161 ( 610) 138 (522) PMG-200 195 602 (2279) 452 (1711) 361 (1367) 301 (1139) 258 (977)
1,000
BTU/HR)
30° (16°) 40° (22°) 50° (28°) 60° (30°) 70° (39°)
Temperature Rise
Note: Installations above 2,000 ft. (610 m) will reduce the above capacities and may
require orifice changes to meet IAS safety compliance. Consult“Installation and Operating Manual”for sizing adjustments and orifice changes.
WATER QUALITY REQUIREMENTS
Incoming water in excess of 3.0 grains of hardness per gallon (GPG) (.75 grains of hardness per liter) must be treated and softened before being supplied to booster heater(s). Water containing over 3.0 GPG (.75 GPL) will decrease the efficiency and reduce the operating life of the unit.
Note: Product failure caused by liming or sediment buildup is not covered under warranty.
Form No. PMG Spec Sheet
Printed in U.S.A.
November 2010
2
4
.
3
2
"
(6
1
8
m
m
)
1
8
.
3
2
"
(4
6
5
m
m
)
24.34" (618 mm)
A
lternate
TPRV on back
2
8
.
3
1
"
(7
2
0
m
m
)
4
" (102 mm) diameterue adapter
FRONT VIEW
R
I
GH
T
S
I
D
E
V
I
E
W
2
4.38" (619 mm)
6.88"
(175 mm)
6
"
(1
5
2 m
m
)
POWERMITE
24.93"
(633 mm)
24.64" (625 mm)
REAR VIEW
RIGHT SIDE VIEW
Water Outlet
G
as
I
nlet
Water I
nlet
Alternate Flue Location
T
PRV
27.45" (697 mm) PMG-100
35.95" (913 mm) PMG-200
30.93"
(786 mm)
31.65" (804 mm) PMG-100
Electrical
40.15" (1020 mm) PMG-200
2
0.73" (526 mm)
6"
(
152 mm)
FRONT VIEW
LEFT SIDE VIEW
Alternate TPRV Location
Water Outlet
Water Inlet
G
as Inlet
®
Models PMG-60, PMG-100, PMG-200
ITEM#
GAS BOOSTER WATER HEATERS
Model PMG-60 & optional PMGH-60 Hood
SPECIFICATIONS
Capacity
PMG-60
PMG-100
PMG-200
Fuel
All Models Natural or Propane Gas
Electrical
PMG-60 120 VAC, 210 watt, 1.75 amps. PMGH-60 120 VAC, 18 watt, 0.15 amps. PMG-100/200 120 VAC, 360 watt, 3.00 amps.
Connections
PMG-60
PMG-100/200
Fluing
PMG-60 Direct – combustion air enters
PMG-100/200 Direct – combustion air enters bottom,
Operating Water Pressure
All Models
ShippingWeight
PMG-60 130 lbs. (59 kg) dry. PMG-100 180 lbs. (82 kg) dry. PMG-200 215 lbs. (98 kg) dry.
Input 58,000 BTUs/Hour.
utput – 46,000 = 13.4kW
O Input 105,000 BTUs/Hour.
utput – 84,800 = 24.8kW
O Input 195,000 BTUs/Hour.
Output – 156,000 = 45.7kW
1
Gas –
2" NPT, Water –3⁄4" NPT,
Electric – 120 VAC, 15 amp.
3
Gas –
4" NPT, Water –3⁄4" NPT,
Electric – 120 VAC, 15 amp.
bottom, flue gasses exit sides at top of unit.
flue gasses exit right side or back at top of unit. 4" (102mm) flue round.
150 PSI max. Relief valve set at 150 PSI, 210° F (99° C)
Models PMG-100 & PMG-200
DIMENSIONS
MG-60: 20.43"W x 24.44"D x 24.32"H* (519 x 621 x 618 mm).
P PMG-100: 27.45"W x 20.73"D x 30.93"H* (720 x 625 x 786 mm). PMG-200: 35.95"W x 24.64"D x 30.93"H* (913 x 625 x 786 mm). PMGH-60 Hood: 24.38"W x 133/8"D+x 6.88"H•(619 x 340 x 175 mm).
Height includes 6" (152 mm) legs.
*
+
dd 4" (102 mm) for flue adapter.
A
Adds 4" (102 mm) to width and 5.88" (149 mm) to height of PMG-60.
Gas Inlet Pressure
Water Column
Gas Type Minimum Maximum
Natural 5.0" (127 mm) 10.5" (267 mm) Propane/LP 11.0" (279 mm) 13.0" (330 mm)
Operating Pressure Specifications at Manifold
Water Column At Pressure Tap
Gas Type High Burn
Natural 3.5" ( 89 mm) Propane/LP 10.0" (254 mm)
^
Vent
PMGH-60 4" (102 mm) diameter vent pipe adapter PMG-100/200 Forced draft system with 4" (102 mm)
^ Before installing any method of venting you should contact the local code authority
or your gas supplier to make sure that the final installation will be acceptable to the authorities who have jurisdiction.
The proper method of venting a power vented gas appliance is too complicated to cover in this specification sheet and is explained in detail in the National Fuel Gas Code. Before installing the venting system, the person or agency making the installation must be familiar and experienced with the guidelines of the National Fuel Gas Code.
ALL INSTALLATIONS MUST BE MADE BY A QUALIFIED INSTALLER IN ACCORDANCEWITH THE NATIONAL FUEL GAS CODE OR LOCAL CODES.
diameter vent pipe adapter.
OPTIONS (NOT FOR RETROFIT)
K Stainless Steel Body, Base, and Sides K Security Package
ACCESSORIES
K Exhaust Hood PMGH-60 (For PMG-60 only)
PRODUCT SPECS
Gas BoosterWater Heater
The Gas BoosterWater Heater to supply the final 180° F (82° C) rinse for the dishwasher shall be a Hatco Powermite commercial use by the Hatco Corporation, Milwaukee, WI 53234 U.S.A.
With 24/7 service (U.S and Canada only), the booster shall have the capacity to heat ... gph (lph) from 110° F to 180° F (43° C to 82° C) and it shall be rated at ... btu, 120 volts, single phase. The stainless steel tank shall be designed for a working pressure of 150 psi (1034 kPa) and hydrostatically tested at 300 psi (2069 kPa).
The heater shall be complete with all internal plumbing, including pipe and fittings from inlet and outlet. All controls shall
be built-in, and carry safety approval in accordance with ANSI 21.10.3.
HATCO CORPORATION P.O. Box 340500 Milwaukee, WI 53234-0500 U.S.A. • (800) 558-0607 • (414) 671-6350 Fax (800) 543-7521 • Int’l. Fax (414) 671-3976 • www.hatcocorp.com • E-mail: equipsales@hatcocorp.com
Form No. PMG Spec Sheet
®
Model ..., as manufactured for
3
⁄4" NPT
K High Altitude Orifice Kit K Air Interlock Switch K Pressure Reducing Valves (Brass or Iron) K 6"-7" (152-178 mm) Adjustable Stainless Steel Legs (4) K Floor Mounting Hardware
Sanitary approval shall be in accordance with NSF Standard 5. Proper surface mounting circuit breaker or fused disconnect switch shall be provided by electrical contractor.
The gas fired heating system shall be controlled by close tolerance immersion thermostats.The booster shall be protected with high temperature limit switch (ECO) and low water cut-off.
The heater shall consist of stainless steel front, top, and stainless steel adjustable legs or stainless steel front and silver-gray hammertone sides and back with standard 6" (152 mm) legs.
The heater shall include a temperature/pressure relief valve, high-temperature limit, pressure reducing valve with bypass, indicating temperature/pressure gauge, shock absorber, and blended phosphate water treatment system.
Printed in U.S.A.
November 2010