ITEM#
HATCO CORPORATION P.O. Box 340500 Milwaukee, WI 53234-0500 U.S.A.
(800) 558-0607 • (414) 671-6350 • Fax (800) 543-7521 • Int’l. Fax (414) 671-3976
www.hatcocorp.com • E-mail: equipsales@hatcocorp.com
Form No. C-1005(S) Printed in U.S.A.
COMPACT
ELECTRIC BOOSTER WATER HEATERS
Models C-4, -5, -6, -7, -9, -12, -13, -15, -17, -18, -24, -27, -30, -36, -39, -45, -54, -57
The Hatco Compact Electric Booster
Water Heater provides all the 180°F (82°C)
final rinse water required to sanitize and
flash-dry dishes and flatware.
FLEXIBILITY
The space saving Compact is easy to
install next to the dishwasher with slide
brackets or on 6" (152 mm) legs. The
storage capacity is 6 gallons (23 liters).
QUALITY
The following features assure the finest
performance for years to come:
• All models include a Castone
®
lined
tank with a 10-year limited warranty.
•
Features include a temperature/pressure
relief valve, a pressure reducing valve,
two temperature/pressure gauges, a
high-temperature limit control, pilot
indicator light, on-off switch, and a
low-water cut-off to prevent element
burnout due to a low water condition.
• Available with slide brackets for
mounting under a dishtable.
• Each booster has fiberglass insulation
to minimize heat loss.
• Hatco electric booster heaters are
factory pre-plumbed and pre-wired
with calibrated immersion thermostat
and high-temperature limit switch.
• A stainless steel front panel and
powder-coated silver-gray hammertone
body is standard on all Compact
models.
• Swing-away front panels with
low-water cut-off, control fuses
and transformer allow quick access
to probes and elements for easier
serviceability.
Model C-18 on
6" (152 mm) legs
Model C-24 on
6" (152 mm) legs
Compact Model 40°F (22°C) Rise 70°F (39°C) Rise
C-4 40 gph ( 151 Iph) 23 gph ( 87 Iph)
C-5 50 gph ( 189 Iph) 29 gph ( 110 Iph)
C-6 60 gph ( 227 Iph) 34 gph ( 129 Iph)
C-7 70 gph ( 265 Iph) 40 gph ( 151 Iph)
C-9 90 gph ( 341 Iph) 52 gph ( 197 Iph)
C-12 120 gph ( 454 Iph) 69 gph ( 261 Iph)
C-13 135 gph ( 511 Iph) 77 gph ( 292 Iph)
C-15 151 gph ( 572 Iph) 86 gph ( 326 Iph)
C-17 173 gph ( 655 Iph) 99 gph ( 375 Iph)
C-18 181 gph ( 685 Iph) 103 gph ( 390 Iph)
C-24 241 gph ( 912 Iph) 138 gph ( 522 Iph)
C-27 271 gph (1026 Iph) 155 gph ( 587 Iph)
C-30 301 gph (1139 Iph) 172 gph ( 651 Iph)
C-36 361 gph (1367 Iph) 206 gph ( 780 Iph)
C-39 391 gph (1480 Iph) 224 gph ( 848 Iph)
C-45 452 gph (1711 Iph) 258 gph ( 977 Iph)
C-54 542 gph (2052 Iph) 310 gph (1174 Iph)
C-57 573 gph (2169 Iph) 326 gph (1234 Iph)
Water Temperature Recovery Table
WATER QUALITY REQUIREMENTS
Incoming water in excess of 3.0 grains of hardness per gallon (GPG) (.75 grains of
hardness per liter) must be treated and softened before being supplied to booster
heater(s). Water containing over 3.0 GPG (.75 GPL) will decrease the efficiency
and reduce the operating life of the unit.
Note: Product failure caused by liming or sediment buildup is not covered
under warranty.
81
OPTIONS (NOT FOR RETROFIT)
❑ All Stainless Steel Body and Base
❑ Slide Brackets (In lieu of Standard 6" (152 mm) Legs)
❑ Adjustable Stainless Steel Legs 6" to 7" (152 to 178 mm)
❑ Brass Pressure Reducing Valve with Bypass
ITEM#
PRODUCT SPECS
Electric Booster Water Heater
The Electric Booster Water Heater to supply the final 180°F
(82°C) rinse for the dishwasher shall be a Compact Model ....as
manufactured for commercial use by the Hatco Corporation,
Milwaukee, WI 53234 U.S.A.
The booster shall have the capacity to heat ....gph (lph) from
120°F to 180°F (49°C to 82°C) and it shall be rated at ....kW,
....volts, ....phase. The tank shall be designed for a working
pressure of 150 psi (1034 kPa) and hydrostatically tested at
300 psi (2069 kPa) with a Hatco Castone
®
lining.
The heater shall be complete with all internal plumbing, including
3
/4" NPT pipe and fittings for inlet and outlet. All controls shall be
built-in, including contactors and prewired in accordance with
UL #1453 and 422.11 NEL 2002. Proper surface mounting
circuit breaker or fused disconnect switch shall be provided
by electrical contractor.
Electric heating elements shall be metal sheathed, controlled
by an ambient compensating immersion thermostat. The booster
shall be protected with high-temperature limit switch (ECO) and
low-water cut-off.
The heater shall consist of stainless steel front and silver-gray
hammertone body with standard 6" (152 mm) legs (or stainless
steel body, base, and stainless steel adjustable legs).
The heater shall include a temperature/pressure relief valve,
high-temperature pressure reducing valve with bypass, and two
indicating temperature/pressure gauges.
COMPACT
ELECTRIC BOOSTER WATER HEATERS
Models C-4, -5, -6, -7, -9, -12, -13, -15, -17, -18, -24, -27, -30, -36, -39, -45, -54, -57
DIMENSIONS
4kW to 18kW: 13"W x 203⁄4"D
(26"
†
) x 133⁄4"H without legs
(330 x 527 (660 mm
†
) x 349 mm).
24kW to 57kW: 18"W x 24"D
(30
1
⁄2"†) x 12"H without legs
(457 x 610 (775 mm
†
) x 305 mm).
†
Includes Temperature/Pressure
Relief Valve.
VOLTAGE
208, 240 and 480 volts available.
Export voltages available.
SPECIFICATIONS
1-Phase 3-Phase
Breaker/ Breaker/ Shipping
Model kW Volts Amps Fuse Size Amps Fuse Size Weight
208 115.4 150 67.7 90
C-24 24 240 100 125
57.8
90 142 lbs. (64 kg)
480 – – 29.9 40
208 129.8 175 75 100
C-27 27 240 112.5 150 65 90 142 lbs. (64 kg)
480 – –
32.5
50
208 144 200
83.3
125
C-30 30 240 125 175
72.3 100
142 lbs. (64 kg)
480 – – 36 50
208 173 225 100 125
C-36 36 240 150 200
86.7
125 142 lbs. (64 kg)
480 – –
43.3
60
208 187.5 250 108 150
C-39 39 240 163.5 225 94 125 142 lbs. (64 kg)
480 – – 47 60
208 – – 125 175
C-45•45 240 188 250 108 150 142 lbs. (64 kg)
480 – – 54 70
208 – – 150 200
C-54••54 240 – – 130 175 142 lbs. (64 kg)
480 – – 65 90
208 – – 158.4 225
C-57••57 240 – – 137.3 200 142 lbs. (64 kg)
480 – – 68.6 90
Models 4-18 kW
Models 24-57 kW
❑ Floor Mounting Hardware
❑ Security Package
ACCESSORIES
❑ Blended Phosphate Water Treatment System
❑ Shock Absorber – To Reduce Water Hammer
1-Phase 3-Phase
Breaker/ Breaker/ Shipping
Model kW Volts Amps Fuse Size Amps Fuse Size Weight
208 19 30 – –
C-4 4 240 17 30 – – 105 lbs. (48 kg)
480 8 15 – –
208 24 30 – –
C-5 5 240 21 30 – – 105 lbs. (48 kg)
480 10 15 – –
208 29 40 25* 40
C-6* 6 240 25 40 22* 30 118 lbs. (54 kg)
480 – – 11* 15
208 34 50 29* 40
C-7* 7 240 29 40 25* 40 118 lbs. (54 kg)
480 – – 13* 20
208 43 60 38* 50
C-9* 9 240 38 50 33* 50 118 lbs. (54 kg)
480 – – 16* 20
208 58 90 33 50
C-12 12 240 50 70 29 40 120 lbs. (54 kg)
480 – – 14.5 20
208 65 90 38 50
C-13 13.5 240 56.3 90 33 50 120 lbs. (54 kg)
480 – – 16.3 30
208 72 90 41.7 60
C-15 15 240 62.5 90 36.1 50 120 lbs. (54 kg)
480 – – 18.1 30
C-17‡17.2 208 – – 47.9 60 120 lbs. (54 kg)
208 86.5 125 – –
C-18§18 240 75 100 43.4 60 120 lbs. (54 kg)
480 – – 21.7 30
* Only 6, 7, & 9kW Models, 208 and 240 volts only, can be field converted
to single phase (units are shipped 3-phase open delta). Larger branch
circuit required than for balanced 3-phase of equal kW. (Balanced 3-phase
available, consult factory.)
‡
17.2kW models available in 208V 3-phase only.
§
18kW models not available in 208V 3-phase.
•
Not available in 208V single phase.
••
Not available in 208V or 240V single phase.
HATCO CORPORATION P.O. Box 340500 Milwaukee, WI 53234-0500 U.S.A. • (800) 558-0607 • (414) 671-6350
Fax (800) 543-7521 • Int’l. Fax (414) 671-3976 • www.hatcocorp.com • E-mail: equipsales@hatcocorp.com
Form No. C-1005(S) Printed in U.S.A.
82
12"
(305 mm)
193⁄4"
(502 mm)
26" (660 mm)
203⁄4" (527 mm)
OUTLET
3
⁄4" NPT
Coupling for
Temperature/Pressure
Relief Valve
INLET
Electical connection
from side or below
SIDE VIEW
3
⁄4"
(19 mm)
77⁄8"
(200 mm)
31⁄2"
(89 mm)
3
⁄4" NPT Nipple
13" (330 mm)
61⁄2" (165 mm)
21⁄4"
2
(6 cm)
(57 mm)
REAR VIEW
1
⁄4
"
(349 mm)
6" (152 mm)
3
13
⁄4"
18"
(457 mm)
301/2" (775 mm)
24" (610 mm)
3
⁄4" NPT
Coupling for
Temperature/Pressure
Relief Valve
Electical connection
from side or below
SIDE VIEW
18" (457 mm)
6"
(152 mm)
OUTLET
77⁄8"
1
31⁄4
"
31/4"
21/4"
(200 mm)
2
⁄4
"
(8 cm)
(83 mm)
(57 mm)
INLET
3
2"
(51 mm)
⁄4" NPT Nipple
(6 cm)
6" (152 mm)