Obey all safety messages that follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
Addresses practices not related to personal injury.
IMPORTANT SAFETY INFORMATION
General Tool Safety Warnings
Read all safety warnings and instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
1. KEEP GUARDS IN PLACE and in working order.
2. REMOVE ADJUSTING KEYS AND WRENCHES.
Form habit of checking to see that keys and adjusting
wrenches are removed from tool before turning it on.
3. KEEP WORK AREA CLEAN.
Cluttered areas and benches invite accidents.
4. DON’T USE IN DANGEROUS ENVIRONMENT.
Don’t use power tools in damp or wet locations,
or expose them to rain. Keep work area well lighted.
5. KEEP CHILDREN AWAY. All visitors should
be kept safe distance from work area.
6. MAKE WORKSHOP KID PROOF with padlocks,
master switches, or by removing starter keys.
7. DON’T FORCE TOOL. It will do the job better
and safer at the rate for which it was designed.
8. USE RIGHT TOOL. Don’t force tool or attachment
to do a job for which it was not designed.
Table A: RECOMMENDED MINIMUM WIRE GAUGE
FOR EXTENSION CORDS
(120 VOLT)
NAMEPLATE
AMPERES
(at full load)
0 – 618161614
6.1 – 1018161412
10.1 – 1216161412
12.1 – 161412Do not use.
9. USE PROPER EXTENSION CORD. Make sure your
extension cord is in good condition. When using
an extension cord, be sure to use one heavy
enough to carry the current your product will
draw. An undersized cord will cause a drop in line
voltage resulting in loss of power and overheating.
Table A shows the correct size to use depending
on cord length and nameplate ampere rating.
If in doubt, use the next heavier gauge.
The smaller the gauge number, the heavier the cord.
10. WEAR PROPER APPAREL. Do not wear
loose clothing, gloves, neckties, rings, bracelets,
or other jewelry which may get caught in moving
parts. Nonslip footwear is recommended.
Wear protective hair covering to contain long hair.
11. ALWAYS USE SAFETY GLASSES. Also use
face or dust mask if sanding operation is dusty.
Everyday eyeglasses only have impact resistant
lenses, they are NOT safety glasses.
12. DON’T OVERREACH.
Keep proper footing and balance at all times.
13. MAINTAIN TOOLS WITH CARE. Keep tools clean
for best and safest performance. Follow instructions
for lubricating and changing accessories.
14. DISCONNECT TOOLS before servicing;
when changing accessories, such as belts.
15. REDUCE THE RISK OF UNINTENTIONAL
STARTING. Make sure switch is in
off position before plugging in.
16. USE RECOMMENDED ACCESSORIES.
Consult the owner’s manual for recommended
accessories. The use of improper accessories
may cause risk of injury to persons.
17. NEVER STAND ON TOOL.
Serious injury could occur if the tool is tipped
or if the belt is unintentionally contacted.
18. CHECK DAMAGED PARTS. Before further use
of the tool, a guard or other part that is damaged
should be carefully checked to determine that
it will operate properly and perform its intended
function – check for alignment of moving parts,
binding of moving parts, breakage of parts,
mounting, and any other conditions that may
affect its operation. A guard or other part that is
damaged should be properly repaired or replaced.
19. DIRECTION OF FEED. Feed work into a belt
against the direction of rotation of the belt only.
20. NEVER LEAVE TOOL RUNNING UNATTENDED.
TURN POWER OFF. Don’t leave tool
until it comes to a complete stop.
SAFETYOPERATIONMAINTENANCESETUP
Grounding Instructions
TO PREVENT ELECTRIC SHOCK AND DEATH FROM INCORRECT GROUNDING WIRE CONNECTION
READ AND FOLLOW THESE INSTRUCTIONS:
110-120 V~ Grounded Tools: Tools with Three Prong Plugs
1. In the event of a malfunction or breakdown,
grounding provides a path of least resistance for
electric current to reduce the risk of electric shock.
This tool is equipped with an electric cord having an
equipment-grounding conductor and a grounding
plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
2. Do not modify the plug provided – if it will
not fit the outlet, have the proper outlet
installed by a qualified electrician.
3. Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
The conductor with insulation having an outer
surface that is green with or without yellow
stripes is the equipment-grounding conductor.
If repair or replacement of the electric cord or
plug is necessary, do not connect the equipmentgrounding conductor to a live terminal.
4. Check with a qualified electrician or service
personnel if the grounding instructions are
not completely understood, or if in doubt as
to whether the tool is properly grounded.
5. Use only 3-wire extension cords that
have 3-prong grounding plugs and 3-pole
receptacles that accept the tool’s plug.
6. Repair or replace damaged or worn cord immediately.
Grounding
Pin
125 V~ 3-Prong Plug and Outlet
(for up to 125 V~ and up to 15 A)
7. This tool is intended for use on a circuit that has
an outlet that looks like the one illustrated above
in 125 V~ 3-Prong Plug and Outlet. The tool has
a grounding plug that looks like the plug illustrated
above in 125 V~ 3-Prong Plug and Outlet.
8. The outlet must be properly installed and grounded
in accordance with all codes and ordinances.
9. Do not use an adapter to connect
this tool to a different outlet.
2. Support workpiece with miter gauge,
backstop, or worktable.
3. Maintain 1/16 inch maximum clearance
between table and sanding belt or disc.
4. The backstop is a fence near the surface that
helps the operator maintain control of the
workpiece and prevents the workpiece from being
pulled into the machine. For safety, it must be
adjusted very close to the sanding surface.
5. The worktable is the surface mounted close to
the sanding surface that the operator rests the
workpiece against to prevent it from being pulled
by the sanding surface. For safety, it must be
adjusted very close to the sanding surface.
6. The sanding belt is designed to rotate down
towards the table while the disc rotates both up
from the table and down towards the table.
7. DO NOT OPERATE WITH ANY GUARD DISABLED,
DAMAGED, OR REMOVED. Moving guards
must move freely and close instantly.
8. The use of accessories or attachments not
recommended by the manufacturer may
result in a risk of injury to persons.
9. When servicing use only identical replacement parts.
13. Industrial applications must follow OSHA guidelines.
14. Maintain labels and nameplates on the tool.
These carry important safety information.
If unreadable or missing, contact
Harbor Freight Tools for a replacement.
15. Avoid unintentional starting.
Prepare to begin work before turning on the tool.
16. People with pacemakers should consult their
physician(s) before use. Electromagnetic fields in
close proximity to heart pacemaker could cause
pacemaker interference or pacemaker failure.
17. WARNING: Some dust created by power
sanding, sawing, grinding, drilling, and other
construction activities, contains chemicals
known [to the State of California] to cause
cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:
• Lead from lead-based paints
• Crystalline silica from bricks and cement or other
masonry products
• Arsenic and chromium from
chemically treated lumber
Your risk from these exposures varies,
depending on how often you do this type of work.
To reduce your exposure to these chemicals:
work in a well ventilated area, and
work with approved safety equipment, such
as those dust masks that are specially
designed to filter out microscopic particles.
(California Health & Safety Code § 25249.5, et seq.)
10. Do not depress the spindle lock when
starting or during operation.
11. Only use safety equipment that has been approved
by an appropriate standards agency. Unapproved
safety equipment may not provide adequate
protection. Eye protection must be ANSI-approved
and breathing protection must be NIOSH-approved
for the specific hazards in the work area.
12. Stay alert, watch what you are doing and use
common sense when operating a power tool.
Do not use a power tool while you are tired or
under the influence of drugs, alcohol or medication.
A moment of inattention while operating power
tools may result in serious personal injury.
Vibration Safety
This tool vibrates during use. Repeated or long-term
exposure to vibration may cause temporary or permanent
physical injury, particularly to the hands, arms and
shoulders. To reduce the risk of vibration-related injury:
18. WARNING: Handling the cord on this product will
expose you to lead, a chemical known to the State
of California to cause cancer, and birth defects or
other reproductive harm. Wash hands after handling.
(California Health & Safety Code § 25249.5, et seq.)
19. The warnings, precautions, and instructions
discussed in this instruction manual cannot
cover all possible conditions and situations
that may occur. It must be understood by the
operator that common sense and caution are
factors which cannot be built into this product,
but must be supplied by the operator.
1. Anyone using vibrating tools regularly or for an
extended period should first be examined by a
doctor and then have regular medical check-ups
to ensure medical problems are not being caused
or worsened from use. Pregnant women or
people who have impaired blood circulation to
the hand, past hand injuries, nervous system
disorders, diabetes, or Raynaud’s Disease should
not use this tool. If you feel any medical or
physical symptoms related to vibration (such as
tingling, numbness, and white or blue fingers),
seek medical advice as soon as possible.
2. Do not smoke during use. Nicotine reduces
the blood supply to the hands and fingers,
increasing the risk of vibration-related injury.
SAVE THESE INSTRUCTIONS.
Specifications
Electrical Rating120V~ / 60Hz / 3A
Belt Speed3260 FPM
Belt Size 1″ x 30″
Dust Port1-3/4″ OD
3. Use tools with the lowest vibration when there
is a choice between different processes.
4. Include vibration-free periods each day of work.
5. Grip workpiece as lightly as possible (while still
keeping safe control of it). Let the tool do the work.
6. To reduce vibration, maintain the tool as
explained in this manual. If any abnormal
vibration occurs, stop use immediately.
SAFETYOPERATIONMAINTENANCESETUP
3092372
Setup - Before Use:
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch of the tool off and unplug the tool from its electrical
SAFETYOPERATIONMAINTENANCESETUP
outlet before performing any procedure in this section.
Note: For additional information regarding the parts listed in the following pages,
refer to the Assembly Diagram near the end of this manual.
5. Replace the Side Cover (1) and
secure it using the Guard Knob (2).
Cover
Knob (2)
Side
Cover
(1)
dust port
Figure A: Side Cover (1) removal
1. Remove Cover Knob (2) and take off
the Side Cover (1). See Figure A.
2. Remove the Bolt (8) from the Locking Handle (18.2).
See Figure B.
Note: Do not lose the Toothed Washer (27)
under the Locking Handle (18.2).
3. Place the Table (34) on the Frame (12)
so that the Sanding Belt (3) fits through
the slot in the Table. See Figure B.
4. Replace the Bolt (8) and secure it using the
Toothed Washer (17) and Locking Handle (18.2).
See Figure B.
Sanding
Belt (3)
Bolt (8)
(under Table)
Table (34)
Locking
Handle (18.2)
Figure B: Table (34) installation
6. Loosen the Screw (13) shown in Figure C.
7. Place the Spark Guard (19) on the top of the Frame
and secure using the Screw (13). See Figure C.
8. Place the Belt Sander on a secure workbench able
to carry the weight of the Belt Sander and stock.
9. Attach the vacuum hose (if used) to the
1-3/4″ dust port on the Side Cover. See Figure A.
Otherwise, attach a vacuum bag (not supplied)
to the port to collect the dust.
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
Tool Set Up
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch of the tool off and unplug the tool from its electrical
outlet before performing any procedure in this section.
TO PREVENT SERIOUS INJURY:
DO NOT OPERATE WITH ANY GUARD DISABLED, DAMAGED, OR REMOVED.
Moving guards must move freely and close instantly.
Removing and Installing Sanding Belt
1. Remove the Cover Knob (2),
then remove the Side Cover (1).
2. Turn the Tracking Knob (28) counterclockwise
to loosen the Sanding Belt (3).
3. Remove the Sanding Belt.
4. Place the new Sanding Belt on the three pulleys.
Center the Sanding Belt on the pulleys.
5. Tighten the Sanding Belt by turning
the Tracking Knob clockwise until the
Rear Driven Wheel (4) appears centered.
6. Replace the Side Cover and Cover Knob.
Tracking
Knob
(28)
Sanding
Belt (3)
Rear
Driven
Wheel (4)
Figure D: Sanding Belt (3) access
SAFETYOPERATIONMAINTENANCESETUP
Cover
Knob (2)
Side
Cover
(1)
7. Check and adjust Sanding Belt tracking before use
as explained in the following section.
Adjusting the Sanding Belt Tracking
1. Turn the Belt Sander on.
2. Look at the Sanding Belt (3) through
the Spark Guard (19):
a. If it is riding on the center of the upper
Driven Wheel (4) the tracking is correct
and no further adjustment is required.
b. If the Belt rides to the left,
turn the Tracking Knob (28) gradually
counterclockwise until the Belt is centered.
2. Turn on Power Switch momentarily to verify that
Sanding Belt is tracking properly.
If Belt tracking needs adjustment, turn Belt Sander off
and refer to instructions on page 7.
If the Sanding Belt is rotating properly with proper
tracking, the Belt Sander is ready for use.
2. Route the power cord along a safe route to reach
the work area without creating a tripping hazard or
exposing the power cord to possible damage. The
power cord must reach the work area with enough
extra length to allow free movement while working.
3. There must not be objects, such as utility lines,
nearby that will present a hazard while working.
SAFETYOPERATIONMAINTENANCESETUP
3. Turn on Power Switch.
4. Push workpiece against belt gradually
to start sanding. Keep hands clear and
do not apply excessive force.
CAUTION! Do not apply so much pressure on object
being sanded to inhibit rotation of sanding belt.
Keep fingers away from the sanding belt.
5. To prevent accidents, turn off the tool and
disconnect its power supply after use. Clean, then
store the tool indoors out of children’s reach.
Procedures not specifically explained in this manual must
be performed only by a qualified technician.
SAFETYOPERATIONMAINTENANCESETUP
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch of the tool off and unplug the tool from its electrical
outlet before performing any procedure in this section.
TO PREVENT SERIOUS INJURY FROM TOOL FAILURE:
Do not use damaged equipment. If abnormal noise or vibration
occurs, have the problem corrected before further use.
Cleaning, Maintenance, and Lubrication
1. BEFORE EACH USE, inspect the general
condition of the tool. Check for:
• loose hardware,
• misalignment or binding of moving parts,
• cracked or broken parts,
• damaged electrical wiring, and
• any other condition that may
affect its safe operation.
2. AFTER USE, wipe external surfaces
of the tool with clean cloth.
3. Replace Sanding Belts when they become
torn or worn down to the paper.
4.
WARNING! If the supply cord of this
power tool is damaged, it must be replaced
only by a qualified service technician.
Troubleshooting
ProblemPossible CausesLikely Solutions
Tool will not start. 1. Cord not connected.
2. No power at outlet.
3. Internal damage or wear. (Carbon
brushes or switch, for example.)
Tool operates
slowly.
Performance
decreases
over time.
Excessive noise
or rattling.
Overheating.1. Forcing machine to work too fast.
Extension cord too long or
wire size too small.
1. Belt dull or damaged.
2. Carbon brushes worn or damaged.
Internal damage or wear. (Carbon
brushes or bearings, for example.)
2. Accessory dull or damaged.
3. Blocked motor housing vents.
4. Motor being strained by long or
small diameter extension cord.
1. Check that cord is plugged in.
2. Check power at outlet. If outlet is unpowered,
turn off tool and check circuit breaker.
If breaker is tripped, make sure circuit is right
capacity for tool and circuit has no other loads.
3. Have technician service tool.
Eliminate use of extension cord. If an extension cord
is needed, use one with the proper diameter for its
length and load. See Table A on page 2.
1. Replace as needed.
2. Have qualified technician replace brushes.
Have technician service tool.
1. Allow machine to work at its own rate.
2. Keep cutting accessories sharp. Replace as needed.
3. Wear ANSI-approved safety goggles and
NIOSH-approved dust mask/respirator while
blowing dust out of motor using compressed air.
4. Eliminate use of extension cord. If an extension cord
is needed, use one with the proper diameter for
its length and load. See Table A on page 2.
Follow all safety precautions whenever diagnosing or servicing
the tool. Disconnect power supply before service.
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards,
and warrants to the original purchaser that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly,
to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper
installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries
to persons or property, or for incidental, contingent, special or consequential damages arising from the use of
our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges
prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise.
If our inspection verifies the defect, we will either repair or replace the product at our election or we may
elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will
return repaired products at our expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353