Harbor Freight Tools 42397, 95683 Product manual

DIGITAL CLAMP MULTIMETER
42397 95683
SET UP AND OPERATING INSTRUCTIONS
Distributed exclusively by Harbor Freight Tools®.
3491 Mission Oaks Blvd., Camarillo, CA 93011
Read this material before using this product.
Failure to do so can result in serious injury. SAVE THIS MANUAL.
Copyright© 2006 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.
For technical questions or replacement parts, please call 1-800-444-3353.
Cover Revised 09f
SPECIFICATIONS
Ranges: 20A/200A/1000A Resolution: 10mA/100mA/1A Accuracy: ± 2.5% rdg +8d* @ 50-60 Hz, 20A
AC Amps
Frequency: 50 - 60 Hz Indication: Average (rms of sine wave) Overload Protection: 1200A within 60 seconds (using clamp, not leads) Range: 200V/750V Resolution: 100mV/1V Accuracy: ± 1.2% rdg +5d @ 200V
AC Voltage
DC Voltage
Resistance
Insulation Test (using 500V insulation tester, not included)
Operating Range 64° F - 82° F optimal, 32° F - 122° F usable, <80% Relative Humidity
Diode Test
Frequency: 45-400 Hz Indication: Average (rms of sine wave) Input Impedance: 9 MW Overload Protection: 750V rms AC Range: 200mV/20V/200V/1000V Resolution: 0.1mV/10mV/100mV/1V Accuracy: ± 0.8% rdg +3d @ 200mV-200V
Input Impedance: 9 MW Overload Protection@ 200mV range: 250V DC Overload Protection@ 20V – 1000V ranges: 1000V AC/DC peak Ranges: 200W/2kW/20kW/200kW/2MW Resolution: 0.1W/1W/10W/100W/1kW Accuracy: ± 1.2% rdg +5d @ 200W
Overload Protection: 250V rms AC Ranges: 20MW/2000MW Resolution: 10kW/1MW Accuracy: ± 2% rdg +2d @20MW
The approximate forward voltage drop of the diode will be displayed.
± 2.5% rdg +5d @ 50-60 Hz, 200A ± 2.5% rdg +5d @ 50-60 Hz, 1000A (for 800A and below) Above 800A the reading is only for reference.
± 2% rdg +5d @ 750V
± 1.2% rdg +5d @1000V
± 1% rdg +3d@ 2kW-200kW ± 1.5% rdg +5d @2MW
± 4% rdg +2d @2000MW (up to 500MW) ± 5% rdg +2d @2000MW (above 500MW)
Continuity Test
Sampling Rate 3 times per second Battery One 9 V (included) Weight 11 oz. Accessories Test leads, battery, and carrying case
*Least signicant digit is the digit farthest right. #d is the number of least signicant digits that a read­ing can be off by.
When resistance <50W, the buzzer will sound.
SKU 42397 / 95683 For technical questions, please call 1-800-444-3353 Page 2
Save This Manual
You will need the manual for the safety warnings and precautions, and operating and maintenance procedures. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.
CAUTION, without
the safety alert symbol, is used to address practices not related to personal injury.
WARNING: If any warnings or safety precautions in the owner’s manual are not followed completely, the protection provided by this product will be reduced.
IMPORTANT SAFETY
INFORMATION
In this manual, on the labeling, and all other information provided with this product:
This is the safety alert
symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates a
hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates
a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION, used with
the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE is used to
address practices not related to personal injury.
Read all instructions before
using this tester!
WARNING
1. ELECTRICAL SHOCK CAN CAUSE DEATH OR INJURY! NEVER TOUCH EXPOSED CONDUCTORS OF ELECTRICITY.
2. Inspect the Multimeter before use. In addition to a general inspection, look
specically for:
a. Pay special attention to the insulation
protecting the connectors.
b. Check the leads for exposed metal,
damaged insulation, and continuity. Replace damaged test leads immediately, before use.
2. Remove the test leads before
performing maintenance, opening the case, or the battery compartment.
3. Do not use the multimeter if:
a. The test leads are damaged in any
way.
b. The battery is low.
c. Near any explosive gasses or fumes.
d. Any abnormal operation is detected.
(If in doubt about the condition of the meter, have it serviced.)
e. The battery cover is open.
4. This meter should be powered only
by a single, correctly installed 9V battery.
SKU 42397 / 95683 For technical questions, please call 1-800-444-3353 Page 3