Instruction Manual
&
(HI 981409) (HI 981410)
EC & TDS Stick Meter
with a user-replaceable
probe
These Instruments are in
http://www.hannainst.com
Compliance with the CE Directives
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for a correct
operation. Please read it carefully before using the meter. If
you need additional technical information, do not hesitate
to e-mail us at tech@hannainst.com.
These instruments are in compliance with the directives
EN 50081-1 and EN 50082-1.
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
Remove the instrument from the packing material and
examine it carefully. If any damage has occurred during
shipment, immediately notify your Dealer or the nearest
Hanna Customer Service Center.
The meters are supplied with:
• HI 1220 EC/TDS probe L: 240 mm with DIN connector
with protective sheath
• 2 batteries AA x 1.5 V type (inside the meter)
• 1500 ppm solution sachet 20 mL for HI 981409
• 5.00 mS/cm solution sachet 20 mL for HI 981410
Note: Conserve all packing material until the instrument
has been observed to function correctly. Any defective
item must be returned in its original packing.
FUNCTIONAL DESCRIPTIONFUNCTIONAL DESCRIPTION
SPECIFICATIONSSPECIFICATIONS
TDS – HI 981409
Range 0 to 1999 mg/L (ppm)
Resolution 1 mg/L (ppm)
Accuracy (@ 25°C/77°F) ±2% f.s.
Typical EMC Deviation ±2% f.s.
Temperature Automatic
Compensation 5 to 50°C (41 to 122°F)
Calibration Automatic at 1500 ppm
ProbeHI 1220 TDS probe L: 240 mm with DIN connector
Batteries 2 x AA alkaline type
(300 hours approx. continuous use)
Auto-shut off after 5 minutes of non-use
Dimensions 86 x 94 x 33 mm (3.4 x 3.7 x 1.3”)
meter only
Weight 150 g (5.3 oz.) meter only
WARRANTYWARRANTY
EC and TDS are warranted for one year against
defects in workmanship and materials when used for their intended
purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If
the instrument is to be returned to Hanna Instruments, first obtain a
Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping
any instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty card
within 14 days from the date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.
Hanna Instruments reserves the right to modify the design, construction
and appearance of its products without advance notice.
GENERAL DESCRIPTIONGENERAL DESCRIPTION
EC and TDS are meters specially designed to
meet the needs of hydroponic and greenhouses.
The housing has been completely sealed against vapors and
humidity. They also float so that they can be quickly
retrieved if accidentally dropped in the tank.
The HI 1220 rugged EC/TDS probe incorporates a fast
responding temperature sensor. This means that readings
are quickly compensated for the temperature effect and they
are accurate every time. The probe can be simply replaced
and the rubber sleeve protects the DIN connector against
humidity and spills. The probe measures 25 cm (10”) and
can even be used to mix the fertilizer solution.
• Ideal for hydroponics and greenhouses
• Waterproof housing floats for quick retrieval
• Automatic calibration
• Auto switch off for longer battery life
• Fertilizer mixer (long and rugged probe)
1. Molded eye
2. Liquid Crystal Display
3. ON/OFF and Calibration button
4. DIN connector
5. Protective sheath
6. HI 1220 EC/TDS probe
7. air-vent hole
EC – HI 981410
Range 0.00 to 10.00 mS/cm (EC)
Resolution 0.01 mS/cm (EC)
Accuracy (@ 25°C/77°F) ±2% f.s.
Typical EMC Deviation ±2% f.s.
Temperature Automatic
Compensation 5 to 50 °C (41 to 122 °F)
Calibration Automatic at 5.00 mS/cm
Probe HI 1220 EC probe L: 240 mm with DIN connector
Batteries 2 x AA alkaline type
(300 hours approx. continuous use)
Auto-shut off after 5 minutes of non-use
Dimensions 86 x 94 x 33 mm (3.4 x 3.7 x 1.3”)
meter only
Weight 150 g (5.3 oz.) meter only
OPERATIONAL GUIDEOPERATIONAL GUIDE
EC/TDS PROBE CONNECTION & MAINTENANCE
In order to protect EC/TDS
against vapors and humidity, the DIN connector is shielded behind a waterproof sheath.
• Slide the protective sheath down. Connect the HI 1220
EC/TDS probe to the DIN connector and then slide the
protective sheath back up all the way up to the EC/TDS
casing. To ensure maximum protection,
make sure the connector is completely covered.
• If the meter remains for a long time on the shelf and is
not used, it is recommended to clean the internal
sensitive pins with alcohol. Immerse the tip of the probe
up to the air-vent hole in alcohol for a few minutes.
• After use, clean the probe with tap water, dry it and
put it away.
• For cleaning after prolonged use, immerse the probe in
HI 7061 Cleaning Solution for ½ hour.
TAKING MEASUREMENTS
• Turn the meter on.
• Immerse the tip 5 cm (2”)
of the EC or TDS probe in
the sample.
Note: In order to have better
accuracy, allow the reading to stabilize. Any initial
variation may be due to
temperature compensation
and the fact that the
probe is adjusting itself
to the new sample.
BATTERY REPLACEMENTBATTERY REPLACEMENT
When the batteries are weak, EC and TDS will
display the warning symbol “Eb”.
To replace the batteries, open the back panel with the help
of a screwdriver and replace both AA type batteries, paying
attention to their polarity.
Batteries should only be replaced in a non hazardous area
using alkaline batteries.
Note: Once the batteries have been replaced, turn the
meter OFF and then ON again. Wait for 30 seconds
to allow the meter to complete the selftest before
performing a new calibration.
CALIBRATIONCALIBRATION
For better accuracy, frequent calibration of the instrument is
recommended.
• Turn the meter on.
• Press and hold the ON/OFF button for approximately 3
seconds. The display will start blinking “1500 ppm” for
HI 981409 and “5.00 ms” for HI 981410 to confirm
that you have entered the calibration mode.
• For TDS immerse the probe in the
HI 70442P and for EC in the HI 70039P
calibration solution.
Stir gently and wait for approximately
20 seconds to auto-confirm the reading.
Note: the probe should be submerged
approximately 5 cm (2”) in the
solution.
• Once the display stops blinking, the EC
or TDS is calibrated and
ready to use.
The instrument should be recalibrated at least once a
month, after cleaning the probe or replacing the batteries.
ERROR CODESERROR CODES
SELF-DIAGNOSTIC ERROR CODES:
Error in calibration, wrong buffer solution
or probe requiring cleanig or replacing.
Over range
Low battery indication
ACCESSORIESACCESSORIES
HI 1220 EC/TDS probe L: 240 mm (10”) with DIN
connector and sensor for Automatic Temperature Compensation incorporated
HI 70039P 5.00 mS/cm (EC) calibration solution, 20 mL
sachet (25 pcs)
HI 70442P 1500 ppm (TDS) calibration solution, 20 mL
sachet (25 pcs)
HI 70442M 1500 ppm (TDS) calibration solution, 230 mL
bottle
HI 7039M 5.00 mS/cm(EC) calibration solution, 230
mL bottle
HI 7061M Probe cleaning solution, 230 mL bottle
CE DECLARATIONCE DECLARATION
OF CONFORMITYOF CONFORMITY
Recommendations for Users
Before using this product, make sure that it is entirely suitable for the environment in
which it is used. Operation of this instruments in residential areas could cause unacceptable interference to radio and TV equipment.
The metal band at the end of the probe is sensitive to electrostatic discharges. Avoid touching
this metal band at all times.
During operation, ESD wrist straps should be worn to avoid possible damage to the probe by
electrostatic discharges.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s
EMC performance.
To avoid electrical shock, do not use this instrument when voltage at the measurement surface
exceed 24 VAC or 60 VDC.
Use plastic beakers to minimize any EMC interferences.
To avoid damage or burn, do not perform any measurement in microwave ovens.
ISTR981409 10/99PRINTED IN PORTUGAL