Item Step Checkpoint Tools Content
1 Check the power
1ǃMeasure the voltage of power with a multimeter,if it beyond standard
scope,adjust it to normal scope;
Notice:measure the power with "AC" of the multimeter.
2ǃCheck connection of power plug and socket,if it's not good,replace or
adjust them.
multimeter,pan-
screwdriver,cross-
screwdriver
Too high or too low voltage of power,bad connection of
power plug and socket will cause compressor(and control
system) couldn't work.
2
Check th
e
compressor start
or not under "test"
mod
e
At the same time,press the two buttons of FRZ temperature adjustment and
hold on for 3 seconds,there will be "T1T1" on display panel,which means
mandatory start mode.
/
The compressor and fan motor will start under this
mode.Check the compressor can work normally or not.If
so,skip steps 5 to 9,if not,skip steps 3 and 4.
3
Check temperature
of FRZ
compartment
Check the FRZ temperature meet the START temperature or not. thermometer
If the FRZ temperature couldn't meet the START
temperature,compressor will not start.
4
Check the FRZ
sensor
Check the resistance of FRZ sensor accord with the actual FRZ temperature
or not.
Notice:Please check the resistance and the temperature data above.
thermometer,multimeter
If the resistance does not accord with the
temperature,compressor will not start because the sensor
passes low temperature parameter to main control PCB.
5 Check connector
Check those connectors of main control PCB,display PCB,Inverter PCB,and
the compressor terminal.
/ Check the wiring of connector fall off or not.
6
Check connection
of "+" and "-".
Make sure that connection of signal input terminal on Inverter PCB is right.
Notice:right of signal input terminal is "+",while the left is "-".
multimeter If it's wrong connection,reconnect them.
7
Test the output of
control signal on
main control PCB
Measure the voltage of two black wires and the red wire(signal control wire)
of Inverter PCB.
Notice:The multimeter must be on "DC",generally speaking,the voltage is
2.5V.
multimeter
If there is no voltage,the signal wire or main control PCB
is bad;if the voltage is too high,the main control PCB is
bad;if the voltage is normal,check power input of inverter
PCB.
8
Check the inverter
PCB
If the voltage is normal,the inverter PCB or compressor is bad.Then replace a
new inverter PCB and check the compressor start or not.
Inverter PCB
If the compressor couldn't start after replacing inverter
PCB,the compressor is bad.
9
Check the
compressor
1ǃAdjust the resistance dial of multimeter to zero,measure the resistance of
the three terminals of compressorDŽIf the voltage is normal,the compressor
doesn't run,but there is sound of "wengweng",the compressor is short-circuit;
2ǃIf the voltage is normal,the compressor doesn't run,and there isn't sound
of "wengweng",the compressor is open-circuit;
3ǃPut the measure pen on shell of compressor,if the lamp of measure pen
is on,there is electricity leakage.
multimeter,pan-
screwdriver,cross-
screwdriver
1ǃThe resistance is abnormally;
2ǃ
Measure resistance of two terminals between the
three ones,if the reading is infinity,there is open-circuit;if
the reading is zero,there is short-circuit;
3ǃConnect one pole of the multimeter with one terminal
while the other pole is connecting with earth wire,if the
resistance is less than 2Mȍ,there is electricity leakage of
compressor.
Instruction of compressor check
EODFNZLUHRQ
ULJKWVLGHLV