Haier RADS-181A user guide manual

0010555512
RADS-181A
1
2
3
1
1
2
4
4
5
5
6-7
8
13-20
14 14
15-20
21-22
22-23
4
5
electronic
touch pad
easy-access
filters
side vent
louvers
vent
controller
6
1.Thermostat
This allows you to adjust the temperature of the air--the lower the setting,the cooler the air temperature. With this you can set the temperature to your desired comfort level. You can set the temperature between 61 F and 86 F.
2.Fan Speed
With this you can control the fan speed as well as the A/C (cooling) speed. You have 3 levels of A/C Speed to set at your desired level. LO will circulate air at the lowest velocity, MED at medium velocity and HIGH will circulate at the maximum, velocity. You have 3 levels of Fan Speed to set at your desired comfort level: HIGH, MED and LOW.
3. Function
Your air conditioner has 4 Functions. a) COOL Here the air conditioner will operate the compressor and the desired fan speed set to give you cold air for your comfort. b) FAN You can run the fan without the A/C function on cooler days. The fan can be set to run at
3 speeds as desired. c) DEHUMIDIFY This enables your air conditioner to operate as a dehumidifier as well. It will remove the excess moisture from the air to keep your room at a comfortable, dry stage. You can use this feature alone in case you do not wish to use the air conditioner. d) ENERGY SAVER When this feature is "On" , the fan will shut off three minutes after the compressor cycles off. This will reduce energy consumption and noise. When the compressor turns back on, the fan will turn on at the same time. In the "Off" position, the fan will not shut off when the compressor cycles off.
4.Timer
Your air conditioner can be set to go on or off at your desire. This can be programmed up to 24 hours in advance.
5.4-Way Air Flow
The air directional louvers let you control the direction of the airflow to the desired direction. The airflow can be directed up-down-right side­left side.
7
6.Vent
The Fresh Air vent allows the air conditioner to recirculat inside air, draw fresh air into the room and exhaust stale air to the outside.
7.Slide Out Chassis
Your air conditioner becomes more versatile with this feature. You have the option to install the unit in a window or the wall.
8. Window Install Kit
This kit enables you to install the air conditioner in a double hung window. Extra brackets or support may be needed, depending on your window.
9.Remote Control
This fully functional wireless remote allows you to operate your air conditioner from a distance. You need not get up to change the settings or the functions, or to turn the unit on or off.
10.LED Display Electronic Control Panel
The 4-function LED displays Room Temperature, Temperature Setting, Timer Setting and Time Remaining to Stop/Start the unit. Electronic
Control Panel lets you set the temperature to the exact temperature you desire.
11.Electrostatic Filter (not all models) Being constructed of high efficiency purifying substance, active carbon fabric, electrostatic fabric, electrostatic active carbon net and other materials, this air conditioner purifies the air effectively. Its wavy structure increases the capability to filter dust and smoke effectively. Due to the retention of active carbon, it has a high purifying speed capable of strong airflow.
12. How The Unit Drains
On humid days with the air conditioner in use, moisture may collect on the pan or the bottom of the air conditioner. If the unit is positioned properly, the moisture will gather towards the back of the unit.This will not affect the operation of the unit and the moisture will evaporate in time. Occasionaly the moisture will flow over the back of the pan, but this will not affect the operation of the unit. Never drill holes in the pan under any circumstance.
8
Cool airflow movement as dictated by the set fan speed. Water sounds. This is normal since your air conditioner also acts as a dehumidifier. Thus you will hear water sounds from water drops falling on the condenser. As the refrigerant flows through the inner sealed tubing, a rushing noise may be occur. Rattling or vibrating noises may be heard due to poor wall or window installation. High pitch compressor sound may be heard.
After installing your air conditioner, plug it into the proper electrical outlet in the wall. Keep the vent in the closed position. Now set the air conditioner at your comfort level. This fully functional wireless remote allows you to operate your air conditioner without having to get up and go to the unit. The full function feature allows you to change the settings and turn the unit on or off from the remote itself. This control pad works the same as the control pad on the air conditioner. (See Fig. #1)
The following sounds are normally heard during the operation of an air conditioner.
9
TEMP/TIME
MODE SPEED TIMER
ON/OFF
Every time you press the MODE button, it will change between FAN, COOL, ENERGY SAVER and DEHUM. (See fig.#3)
After you plug in the unit, it will perform a self test. All the display lights will turn on for 3 seconds. The LED display will read"88". If any display light fails to turn on you may need service on the unit. After 3 seconds, the unit will automatically go to the stand by mode. Now all lights will be off and you will have to turn"ON" by pressing the On/Off key. After pressing"On/Off", the unit starts to work and enters the status of "Fan" with the low setting. You will have to press the ( ) or ( ) key on the Temp/Time to set the temperature at your desired comfort. You can choose a temperature between 61
o
F and 86oF. Once the temperature is set you can raise or lower it by pressing the ( ) or ( ) keys.The temperature setting can only be adjusted when the unit is in cooling, energy saver, or dehumidify mode.(See Fig. #2) Having set the temperature, you will set the function of the air conditioner.
10
TEMP/TIME
MODE SPEED TIMER
ON/OFF
Once the mode function is established, you will have to set the fan speed. (See fig. #4) Every time you press the SPEED button, fan speed will change between LOW, HIGH and MED.
1) If you choose the COOL mode you can run the fan in one of the 3 speeds: HIGH, MED, or LOW.
2) For cool days you may want to run the "FAN" function. Here the fan runs at one of 3 speeds (HIGH fan, MED fan, LOW fan) as desired by you.
3) The dehumidify function removes excess moisture from the air on excessively humid days. Tr: temperature inside the room. Ts: the set temperature.
1) When Tr>Ts+3
o
F, the compressor will run the fan continuously at the selected speed.
2) When Ts-1
o
F¡ Tr¡ Ts+3oF, the compressor will cycle for 10 minutes on and 6 minutes off.
3) When Tr<Ts-1
o
F, the compressor will shut off.
The dehumidification process takes place between the set temperature-1 and 3
o
F above
the set temperature.
4) Energy Saver: The unit runs the same as the COOL setting in the ENERGY SAVER mode. But the fan will be off 3 minutes after the compressor cycle off.
11
TEMP/TIME
MODE SPEED TIMER
ON/OFF
Timer off ( See Fig. #5) The unit must be running to set time off. Use this to preset the time you would like the unit to shut off. a) Press TIMER OFF. LED display will show "XX" (time set last time).When power is connected for the first time, LED display will show "01". b) Set desired number by pressing the ( ) pad of the Temp/Time buttons, once for each hour. If you pass the desired time, use the ( ) pad key to lower the selection. c) After you set TIMER OFF, LED display will show the room temperature about 5 seconds later. When using the timer, the unit will revert to the last COOL and FAN settings when activated. The timer must be reset every time you choose to use it.
Timer On or Timer Off mode is used to pre-start or shut off your unit in advance. You can program this up to 24 hours in advance. You can use the Timer in 4 functions, i.e. COOL, ENERGY SAVER, DEHUMID or FAN. Timer on (See Fig.#5) The unit must be on to set the timer. Unit will shut down automatically after it accepts the settings in 5 seconds. Use this mode to pre-set the start time of the unit 24 hours in advance. a) Press TIMER ON. LED display will show "XX" (time set last time). When power is connected for the first time, LED display will show "01". b) Set the desired number of hours by pressing the ( ) pad of the Temp/Time buttons, once for each hour. If you passed the desired time, use the ( ) pad key to lower the selection. c) After you set TIMER ON, LED display will show the time. This time displayed means: the unit will starts after X hours.
12
Fig. # 5
TEMP/TIME
MODE SPEED TIMER
ON/OFF
Adjusting the Air Flow Direction
Airflow can be adjusted by changing the direction of the air conditioner's louvers. This can also increase the cooling efficiency of the air conditioner.
Adjusting Horizontal Air Flow Direction
Adjusting the vertical louvers left and right will change horizontal airflow.
Adjusting Vertical Air Flow Direction
Adjusting the horizontal vane up and down will change vertical airflow. The vane can be adjusted by nudging the back of the vane up and down.
Adjusting Horizontal Air Flow
Adjusting Vertical Air Flow
Recommended orientation of louvers: Adjust louvers to face upwards when cooling to maximize cooling efficiency.
13
Before you install your air conditioner, check the following:
1) The unit is free of all obstructions inside and outside the room, e.g. drapes, curtains,
furniture, plants, shrubs, bushes, trees, other structures like buildings, garage, etc.
The air conditioner must have a clear, unobstructed airflow through the condenser to
remove heat.
2) The window is strong enough to hold the weight of the air conditioner. Extra brackets
or supports may be needed depending on your windows. (Brackets or supports not
provided in all models)
3) The windowsill and track are strong enough to hold the weigh of the air conditioner.
4) The wall is strong enough to hold the unit. Extra brackets or supports may be needed
depending on the wall. (Brackets or supports not provided in all models).
5) There is adequate and proper power supply near the air conditioner.
6) DO NOT use adapter plugs.
7) DO NOT use extension cords.
8) DO NOT cut or remove the ground prong.
9) DO NOT modify the plug or the electrical wall outlet in any way. If plug does not
fit the electrical outlet have a certified electrician do the necessary change.
10) DO NOT connect electrical power to the unit before installation.
11) DO NOT use if power cord is worn out, frayed or otherwise damaged. Avoid using
if there are cracks or abrasion damage along the length, plug or connection.
12) Be careful of exposed sharp edges of the cabinet and sharp coils (fins) on the
back of the unit that could cut and cause serious injury.
14
Parts
Parts Supplied
installation bracket (left and right)
2
1/2
" long flat head bolt and locknut
top rail
left and right side
curtains
19/32" long screw and locknut
window seal gasket
curtain attachment screws 13/32"
basepan angle
wood screws 31/32"
CR2025 battery
Remote control
Model:
RADS-181A
Installing Unit into A Window
Window Opening Requirements
The air conditioner is designed to fit into double or single hung sash type windows. Each of the units comes with an installation kit that provides adjustable mounting louvers to fill the gaps between the sides of the unit and the window frame. The chart below reflects the dimensions of the units with and without installation kits. Measure your window opening width and compare it to the chart below to ensure that it meets the minimum and maximum window width requirements.
RADS-181A
Model
A(inch)
Dimension
B(inch)
C(inch)
D(inch) Max
Case High
Case Width
D(inch) Min
Case Depth
A
B
C
RADS-181A
15
D
11
5
2
18
5
3
20
4
1
40
30
18
32
21
26
16
9
25
3
2
Unpack unit on the floor next to installation location. Remove two front attachment screws. Separate the outer case from the front with a putty knife at the catch points designated by the arrows. Remove the two screws on top of the outer case. Using the basepan handle, slowly and evenly pull chassis out from outer case. Note: Cover putty knife blade with masking tape to guard against damage of the unit finish.
Caution: Never expose plastic front or grille to extreme temperatures.
16
Install top rail with four 13/32" screws. Slide left-hand curtain assembly into left end of top and bottom rails. Repeat for right-hand curtain assembly. Fasten curtain retainer strips to the sides of the outer case with six 13/32" screws.
Measure the width between the window moldings to ensure the Instant Mount will fit the window frame. Instant Mount models are designed for windows wide (for details see page 15)
ASSEMBLE CURTAINS/TOP RAIL
2
PREPARE WINDOW FOR INSTALLATION
Inspect window track, sash, and sill for its ability to support the weight of air conditioner.
s(not
3
Mobile home window installation
Add wood strip (at least 1 1/2" wide) along entire width of window sill. Thickness of wood strip should match height of front lip on window frame. Fasten wood strip to sill with a minimum of three countersunk wood screws (not supplied with kit). This provides a smooth surface for mounting air conditioner.
Storm window installation
If storm window frame does not allow adequate clearance below sill (1/2" required), remove storm window frame or create clearance by adding a wood strip (at least 1 1/2" wide) along entire width of sill. Fasten wood strip to sill with at least three countersunk wood screws (not supplied with kit). This provides a smooth surface for mounting air conditioner.
SILL
Wood
Strip
1/2"
Minimum
O U T D O O R
Storm Window Frame
1 1/2"
Minimum
I N D O O R
11/2"
Minimum
Wood
Strip
I N D O O R
O U T D O O R
Window
Frame
Must be a minimum
of 1/2" to clear
bottom rail on unit
17
4
INSTALL OUTER CASE IN WINDOW
Place outer case in window. Lower sash until it rests behind front flange of top rail. Bottom rail must rest behind window sill.
Expand both curtains to contact the window frame. Install four wood screws 31/32". Two in each upper right and left of the curtains.
NOTE: To make screws easier to drive, drill a pilot hole into the sash through clearance hole in curtains.
Install three wood screws 31/32" top mounting rail screws.
Use two wood screws 31/32" to fix the case to windows sash. Install left & right installation bracket and as shown in fig. Install bolt(2
1/2" long flat head
bolt and locknut) to the installation bracket and adjust them to proper length ,then use 4 (19/32")screws to fix the bracket on the case.
Top rail
Bottom rail
Curtain assembly cut
away for clarity.
About
18
Install sash bracket on top of indoor window sash with one wood screw 31/32" to prevent raising of window from the outside. Screw the anchor directly into the side of window frame. For hard wood or metal window frames, drill a pilot hole to start the screw.
Important:Be careful not to drill the pilot hole too deep. Add a piece of tape to the drill bit as a depth gauge. Also stay clear of glass. Be careful not to damage the function of the window.
Cut window seal gasket to width of window. Stuff window seal strip between the outdoor window glass and the top of the indoor sash. This will stop air leakage which reduces efficiency.
INSTALL SASH BRACKET & SEAL GASKET
6
5
Caution:
Find someone to help you replace the chassis in outer case. Replace front panel and grille.
For security purposes, reinstall screws at cabinet's sides, removed in step one.
Because the window sash helps keep the unit in window, make certain the window sash contacts the outer case before reinstalling the chassis.
19
Remove the 2 shipping screws on the top of the air conditioner that hold the chassis to the outer shell casing.
20
21
Always unplug your air conditioner before cleaning.
DO NOT use your air conditioner without the air filter in place.
The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner.
How to remove the air filter:
1. The grille may be opened from the top for easy maintenance after installation.
2. Open the inlet grille by pulling off the exposed door on the top of the unit (based on the installation).
3. Pull the tab slightly to release the filter. Pull the filter in the same direction as the opening.
4. Clean the filter with warm, soapy water. The water should be below 40
o
C(104oF).
5. Rinse off and gently shake off excess water from the filter. Let it dry before replacing it.
Always use a soft cloth dampened with water or mild soap and water solution to wipe the front if the cabinet.
To clean the front panels or the cabinet DO NOT use harsh chemicals, abrasives, ammonia, chlorine, bleach, concentrated detergents, solvents or metal scouring pads.
22
23
8
17
Vent may be in the open position. Vent has to be closed for optimum cooling.
Loading...