Haier QPHR50LZ Installation Manual

0 (0)

Owner’s Manual and

Installation Instruction

Manual del propietario y instrucciones de instalación

QPHR50

Dehumidifier

Deshumidificador

Design may vary by model number.

El diseño puede variar según el número de modelo

49-5000429 Rev. 2 01-20 GEA

ENGLISH

2

49-5000429 Rev. 2

TABLE OF CONTENTS

SAFTEY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 CONTROL PANEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 USING THE DEHUMIDIFIER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 CARE AND CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

ENGLISH

RECORD KEEPING

Thank you for purchasing this Haier product. This user manual will help you get the best performance from your new dehumidifier.

Para referencia futura, registre el modelo y el número de serie ubicados en el deshumidificador y la fecha de compra.

Staple your proof of purchase to this manual to aid in obtaining warranty service if needed.

____________________________________________________

Model number

____________________________________________________

Serial number

____________________________________________________

Date of purchase

HAIER WEBSITE

Have a question or need assistance with your appliance? Try the Haier Website 24 hours a day, any day of the year! You can also shop for more great Haier products and take advantage of all our on-line support services designed for your convenience. In the US: Haierappliances.com

49-5000429 Rev. 2

3

Haier does not support any servicing of the dehumidifier. We strongly recommend that you do not attempt to

ENGLISH

SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

Use this appliance only for its intended purpose as described in this Owner’s Manual.

This dehumidifier must be properly installed and grounded

service the dehumidifier yourself.

 

as described in this manual before it is used.

For your safety, do not store or use combustible materials,

Never operate this dehumidifier in an area that is likely to

gasoline or other flammable vapors or liquids in the vicinity

 

accumulate standing water. If this condition develops, for

of this or any other appliance.

 

your safety disconnect the power supply before stepping

All dehumidifiers contain refrigerants, which under federal

 

into the water.

law must be removed prior to product disposal. If you are

Never unplug your dehumidifier by pulling on the power

getting rid of an old product with refrigerants, check with

 

cord. Always grip plug firmly and pull straight out from the

the company handling disposal about what to do.

 

receptacle.

Do not use outdoors.

Replace immediately all electric service cords that have

This dehumidifier is intended for indoor residential

 

become frayed or otherwise damaged. A damaged power

applications only. This dehumidifier should not be used for

 

supply cord must be replaced with a new power supply cord

commercial or industrial applications.

 

obtained from the manufacturer and not repaired. Do not

These R410A Dehumidifier Systems require contractors

 

use a cord that shows cracks or abrasion damage along its

and technicians to use tools, equipment and safety

 

length or at either the plug or connector end.

standards approved for use with this refrigerant. DO NOT

If the receptacle does not match the plug, the receptacle

use equipment certified for R22 refrigerant only.

 

must be changed out by a qualified electrician

This appliance can be used by persons with reduced physical,

If the SUPPLY CORD is damaged, it must be replaced by the

sensory or mental capabilities or lack of experience and

 

manufacturer, its service agent or similarly qualified person

knowledge if they have been given supervision or instruction

 

in order to avoid a hazard.

concerning use of the appliance in a safe way and understand

The appliance shall be installed in accordance with national

the hazards involved.

 

wiring regulations.

 

Turn the dehumidifier OFF and unplug it before cleaning.

 

 

 

 

 

 

 

 

 

 

WARNING

USE OF EXTENSION CORDS

 

 

RISK OF FIRE. Could cause serious injury or death.

DO NOT use surge protectors or multi-outlet adaptors

DO NOT use an extension cord with this Dehumidifier.

with this Dehumidifier.

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The dehumidifier should always be plugged into its own individual electrical outlet, which has a voltage rating matching the rating plate.

This provides the best performance and also prevents overloading house wiring circuits, which could cause a fire hazard from overheated wires.

RECYCLING INFORMATION

For appliance recycling information please visit www.geappliances.com/recycling.

READ AND SAVE THESE INSTRUCTIONS

4 49-5000429 Rev. 2

CONTROLS

Appearance may vary by model.

Humidity %

Controls

NOTE: Whenthebucketisfullorremoved,thecontrolscannotbeset.

1. Power Pad

Press to turn the dehumidifier on and off.

" ПдсЬуииз Щдз

Controls the fan speed.

Press to select either High, Medium, Low, or Smart Dry fan speed.

Set the fan control to High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to Medium or Low.

Smart Dry compares the set humidity level with the actual humidity and adjusts the fan speed automatically.

3. Display

Shows the set % humidity level while setting, then shows the actual (+/– 5% accuracy) room % humidity level.

$ СшрмзмчьЬичМтсчхтп Щдзц

Элилшрмзмчьпищипждсеицичъмчлмсдхдскитй#%]ЫС¤Ыипдчмщи

Сшрмзмчь¥чт( ]ЫС¤ЫипдчмщиСшрмзмчь¥мс%]мсжхирисчцтхдчЧЬ for continuous operation. To set the unit for continuous operation, press the pad until the screen reads NS.

NOTE: If NS (Nonstop) is selected, the dehumidifier will operate continuously at its maximum dehumidification settings if attached to a hose to drain or until the bucket is full.

For drier air, press the pad and set to a lower percent value (%). For damper air, press the pad and set to a higher percent value (%).

When you first use the dehumidifier, set the humidity control to 45% or 50%. Allow at least 24 hours for the dehumidifier to achieve the humidity level. If you still have damper air than desired, set the humidity level to a lower setting or select Nonstop for maximum dehumidification.

5. Filter Timer

Press and hold filter button for 3 seconds to reset the filter reminder. See the Care and Cleaning section.

6. Delay Off

While the dehumidifier is operating press the Delay button.

Press the / buttons to select the number of hours you want the dehumidifier to continue to operate before turning Off.

NOTE: After displaying the time, the Display will revert to showing the current humidity after 5 seconds have passed. Pressing the Delay button will display the number of hours left on the delay.

Delay On

While the dehumidifier is off press the Delay button.

Press the / buttons to select the number of hours you want the dehumidifier to remain off before turning On.

NOTE: The display will show the number of hours left until the dehumidifier turns on.

To cancel the Delay:

Press the Delay button once, the hours remaining on the Delay will appear on the display. Press the Delay button again and the Delay will be cancelled.

7. Pump

Activates the internal pump function. Press for 3 seconds to activate the internal pump for automatic removal of condensate. The internal pump indicator light will remain illuminated after 3 seconds. Press to deactivate the pump.

8. Empty Indicator

The “Empty” indicator will blink when the bucket is ready to be emptied, or when the bucket is removed and/or not replaced in the proper position.

After 250 hours of operation, the Clean the Filter indicator light will glow to remind you to clean the filter. Remove the filter and clean it.

Other Features

Alarm

If the bucket is full or missing, an alarm will sound for about 10 seconds to remind you to empty and replace the bucket.

Auto Shut Off

The Water Level Control Switch shuts off the dehumidifier when the bucket is full, or when the bucket is removed and/or not replaced in the proper position.

NOTE: Fan will continue to run approximately 3 minutes after bucket

49-5000429 Rev. 2

is removed.

Auto Defrost

When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.

Power Outage

In the case of a power outage or interruption, the unit will automatically restart, in the settings last used, after the power is restored.

5

ENGLISH

ENGLISH

USING THE DEHUMIDIFIER

When first using the dehumidifier, operate the unit continuously for 24 hours.

How the Dehumidifier Operates

Moist, humid air is drawn over a cold refrigerated dehumidifying

It is normal for the surrounding air to become slightly warmer as

coil. Moisture in the air condenses on this coil and drains into a

the dehumidifier operates.

bucket (or through a hose and drain).

 

Dry, clean air is drawn through the condenser where it is heated

 

and discharged out the top grille into the room.

 

Automatic Defrost

When frost builds up on the evaporator coils, the compressor

When the coil is defrosted, the compressor or fan will

will cycle off and the fan will continue to run until the frost

automatically restart and dehumidifying will resume.

disappears.

 

Choosing a Location

A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

Do not use outdoors.

This dehumidifier is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications.

Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full bucket of water.

Allow at least 18 inches of air space on all sides of the unit for good air circulation.

Place the dehumidifier in an area where the temperature will not fall below 41°F (5°C) or above 90°F (32°C). The coils can become covered with frost at temperatures below 41°F, which may reduce performance.

The suggested range of relative humidity is between 40% and 50%

Use the dehumidifier in cooking, laundry, bathing and dishwashing areas that have excessive moisture.

NOTE: Place the dehumidifier away from the clothes dryer.

Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored.

Use the dehumidifier in a basement to help prevent moisture damage.

The dehumidifier must be operated in an enclosed area to be most effective.

Close all doors, windows and other outside openings to the room.

Correct

Wrong

Above

Below

41 °F

41 °F

(5 °C)

(5 °C)

at

least

 

 

 

 

18

inches

inches

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

least

 

 

 

 

at

NOTE: The dehumidifier has rollers to aid placement, but it should only be rolled on smooth, flat surfaces. Do not attempt to roll the dehumidifier on carpet or over objects.

6

49-5000429 Rev. 2

Haier QPHR50LZ Installation Manual

USING THE DEHUMIDIFIER

Always make sure the water bucket is locked into place on the dehumidifier.

Removing Collected Water

There are 3 ways to remove collected water:

3. Thread a garden hose (not supplied) onto the nozzle, cut to

Use the bucket. When the bucket is removed, the unit will shut

length, and lead it to the floor drain.

off. Empty and replace the bucket.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

IMPORTANT: Do not use the hose if using the bucket to collect water. When the hose is connected, water will flow through it onto the floor instead of into the bucket.

NOTES:

Do not remove the bucket while the dehumidifier is operating or if it has just stopped operating. This might cause some water to drip from the drain pan.

The bucket must be in place and securely seated for the dehumidifier to operate.

Use a hose. Water can be automatically emptied into a floor drain by attaching a garden water hose (not included).

1.Remove the bucket from the front of the unit.

2.Open the drain cover on the side of the unit.

4. Replace the bucket in the unit.

NOTE: The bucket must be in place and securely seated for the dehumidifier to operate.

Use the internal pump. Water can be automatically emptied into a remote location by attaching the included pump hose.

1.Attach the pump hose to the hose connector by pushing the tube fitting into the connector until it fits into place (should not be able to remove the hose when pulled).

2.Position the hose discharge to the desired location.

3.Make sure the pump is activated. To activate the pump, press and hold the Pump button for 3 seconds. The Pump indicator light will flash then remain illuminated once the 3 seconds are complete.

IMPORTANT: Make sure the condensate hose is properly connected and is not kinked, bent or cracked as this may cause water to flow onto the floor. The bucket must also be fully seated for the pump to work properly. Do not operate the machine if the room temperature is 41°F or below.

NOTE: Maximum lift height is 16ft.

49-5000429 Rev. 2

7

Loading...
+ 16 hidden pages