Thank you for pur chasing this Haier product. This user
manual will help you get the best performance from your new
dehumidifier.
For future reference, record the model and serial number
located on the dehumidifier and the date of purchase.
Staple your proof of purchase to this manual to aid in
obtaining warranty service if needed.
____________________________________________________
Model number
____________________________________________________
Serial number
____________________________________________________
Date of purchase
HAIER WEBSITE
Have a question or need assistance with your appliance? Try the Haier Website 24 hours a day, any day of the year! You
can also shop for more great Haier products and take advantage of all our on-line support services designed for your
convenience. In the US, please visit: Haierappliances.com
49-5000429 Rev. 43
ENGLISH
SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING
shock or personal injury.
•
Use this appliance only for its intended purpose as
described in this Owner’s Manual.
•
This dehumidifier must be properly installed and grounded
as described in this manual before it is used.
•
Never operate this dehumidifier in an area that is likely to
accumulate standing water. If this condition develops, for
your safety disconnect the power supply before stepping
into the water.
•
Never unplug your dehumidifier by pulling on the power
cord. Always grip plug firmly and pull straight out from the
receptacle.
•
Immediately replace all electric service cords that have
become frayed or otherwise damaged. A damaged power
supply cord must be replaced with a new power supply cord
obtained from the manufacturer and not repaired. Do not
use a cord that shows cracks or abrasion damage along its
length or at either the plug or connector end.
•
If the receptacle does not match the plug, the receptacle
must be changed out by a qualified electrician
•
If the SUPPLY CORD is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified person
in order to avoid a hazard.
•
The appliance shall be installed in accordance with national
wiring regulations.
For your safety, the information in this manual must be followed to minimize the risk of fire, elec tric
•
Turn the dehumidifier OFF and unplug it before cleaning.
•
Haier does not support any servicing of the dehumidifier.
We strongly recommend that you do not attempt to
service the dehumidifier yourself.
•
For your safety, do not store or use combustible materials,
gasoline or other flammable vapors or liquids in the vicinity
of this or any other appliance.
•
All dehumidifiers contain refrigerants, which under federal
law must be removed prior to product disposal. If you are
getting rid of an old product with refrigerants, check with
the company handling disposal about what to do.
•
Do not use outdoors.
•
This dehumidifier is intended for indoor residential
applications only. This dehumidifier should not be used for
commercial or industrial applications.
•
These R410A Dehumidifier Systems require contractors
and technicians to use tools, equipment and safety
standards approved for use with this refrigerant. DO NOT
use equipment certified for R22 refrigerant only.
•
This appliance can be used by persons with reduced physical,
sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand
the hazards involved.
WARNING
RISK OF FIRE. Could cause serious injury or death.
•
DO NOT use an extension cord with this Dehumidifier.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord. For personal safety, this
appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong
(grounding) wall outlet to minimize the possibility of electric
shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
RECYCLING INFORMATION
For appliance recycling information please visit www.geappliances.com/recycling.
USE OF EXTENSION CORDS
•
DO NOT use surge protectors or multi-outlet adaptors
with this Dehumidifier.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced with
a properly grounded 3-prong wall outlet.
The dehumidifier should always be plugged into its own
individual electrical outlet, which has a voltage rating
matching the rating plate.
This provides the best performance and also prevents
overloading house wiring circuits, which could cause a fire
hazard from overheated wires.
READ AND SAVE THESE INSTRUCTIONS
449-5000429 Rev. 4
CONTROLS
Appearance may vary by model.
Controls
NOTE: When the bucket is full or removed, the controls cannot be set.
1. Power Pad
Press to turn the dehumidifier on and off.
NOTE: Turning off the power by pressing the Power button does
NOT disconnect the appliance from power supply.
"ПдсЬуиизЩдз
Controls the fan speed.
Press to select either High, Medium, Low, or Smart Dry fan speed.
Set the fan control to High for maximum moisture removal. When
the humidity has been reduced and quiet operation is preferred,
set the fan control to Medium or Low. Smart Dry compares the set
humidity level with the actual humidity and adjusts the fan speed
automatically.
3. Display
Shows the set % humidity level while setting, then shows the
actual (+/– 5% accuracy) room % humidity level.
in Nonstop mode for continuous operation. To set the unit for
continuous operation, press the
indicator light is illuminated.
NOTE: If Nonstop is selected, the dehumidifier will operate
continuously at its maximum dehumidification settings if attached
to a hose to drain or until the bucket is full. For drier air, press the
pad and set to a lower percent value (%).
the pad and set to a higher percent value (%).
the dehumidifier, set the humidity control to 45% or 50%. Allow at
least 24 hours for the dehumidifier to achieve the humidity level.
If you still have damper air than desired, set the humidity level to a
lower setting or select Nonstop for maximum dehumidification.
pad until the “Nonstop”
For damper air, press
When you first use
Other Features
Humidity %
5. Filter Timer
After 250 hours of operation, the Clean the Filter indicator light will
glow to remind you to clean the filter. Remove the filter and clean it.
Press and hold Filter button for 3 seconds to reset the filter
reminder. See the Care and Cleaning section.
6. Delay Off
While the dehumidifier is operating press the Delay button.
Press the
the dehumidifier to continue to operate before turning Off.
NOTE: After displaying the time, the Display will revert to showing
the current humidity after 5 seconds have passed. Pressing the
Delay button will display the number of hours left on the delay.
Delay On
While the dehumidifier is off press the Delay button.
Press the
the dehumidifier to remain off before turning On.
NOTE: The display will show the number of hours left until the
dehumidifier turns on.
To cancel the Delay:
Press the Delay button once, the hours remaining on the Delay will
appear on the display. Press the Delay button again and the Delay
will be cancelled.
7. Pump
Activates the internal pump function. Press for 3 seconds to
activate the internal pump for automatic removal of condensate.
The internal pump indicator light will remain illuminated after 3
seconds. Press to deactivate the pump. Before turning on the
pump, ensure the hose is connected.
8. Empty Indicator
The “Empty” indicator will blink when the bucket is ready to be
emptied, or when the bucket is removed and/or not replaced in the
proper position.
Hold 3 Sec
Requires Hose
/ buttons to select the number of hours you want
/ buttons to select the number of hours you want
ENGLISH
Alarm
If the bucket is full or missing, an alarm will sound for about 10
seconds to remind you to empty and replace the bucket.
Auto Shut Off
The Water Level Control Switch shuts off the dehumidifier when the
bucket is full, or when the bucket is removed and/or not replaced
in the proper position. An alarm will sound if the water level control
switch is not reset.
49-5000429 Rev. 45
NOTE: The fan and compressor will stop running as soon as the
bucket is removed.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will
cycle off and the fan will continue to run until the frost disappears.
Power Outage
In the case of a power outage or interruption, the unit will automatically
restart, in the settings last used, after the power is restored.
ENGLISH
USING THE DEHUMIDIFIER
When first using the dehumidifier, operate the unit continuously for 24 hours.
How the Dehumidifier Operates
Moist, humid air is drawn over a cold refrigerated
dehumidifying coil. Moisture in the air condenses on this coil
and drains into a bucket (or through a hose and drain).
Dry, clean air is drawn through the condenser where it is
heated and discharged out the top grille into the room.
Automatic Defrost
When frost builds up on the evaporator coils, the compressor
will cycle off and the fan will continue to run until the frost
disappears.
Choosing a Location
A dehumidifier operating in a basement will have little or no
effect in drying an adjacent enclosed storage area, such as a
closet, unless there is adequate circulation of air in and out of
the area.
• Do not use outdoors.
• This dehumidifier is intended for indoor residential
applications only. This dehumidifier should not be used for
commercial or industrial applications.
• Place the dehumidifier on a smooth, level floor strong
enough to support the unit with a full bucket of water.
• Allow at least 18 inches of air space on all sides of the unit
for good air circulation.
• Place the dehumidifier in an area where the temperature
will not fall below 41°F (5°C) or above 90°F (32°C). The coils
can become covered with frost at temperatures below
41°F, which may reduce performance.
• The suggested range of relative humidity is between 40%
and 50%
• Use the dehumidifier in cooking, laundry and dishwashing
areas that have excessive moisture.
NOTE: Place the dehumidifier away from the clothes dryer.
• Use the dehumidifier to prevent moisture damage
anywhere books or valuables are stored.
• Use the dehumidifier in a basement to help prevent
moisture damage.
• The dehumidifier must be operated in an enclosed area to
be most effective.
• Close all doors, windows and other outside openings to the
room.
It is normal for the surrounding air to become slightly warmer
as the dehumidifier operates.
When the coil is defrosted, the compressor or fan will
automatically restart and dehumidifying will resume.
NOTE: The dehumidifier has casters to aid placement, but
it should only be rolled on smooth, flat surfaces. Do not
attempt to roll the dehumidifier on carpet or over objects.
CorrectWrong
Above
41 °F
(5 °C)
at least 18 inches
Below
41 °F
(5 °C)
at least 18 inches
649-5000429 Rev. 4
USING THE DEHUMIDIFIER
Always make sure the water bucket is locked into place on the dehumidifier.
Removing Collected Water
There are 3 ways to remove collected water:
Use the bucket. When the bucket is removed, the unit will shut
off. Empty and replace the bucket.
IMPORTANT: Do not use the hose if using the bucket to collect
water. When the hose is connected, water will flow through it
onto the floor instead of into the bucket.
NOTES:
• Do not remove the bucket while the dehumidifier is operating
or if it has just stopped operating. This might cause some
water to drip from the drain pan.
• The bucket must be in place and securely seated for the
dehumidifier to operate.
Use a hose. Water can be automatically emptied into a floor
drain by attaching a garden water hose (not included).
3. Thread a garden hose (not supplied) onto the nozzle and
ensure it is seated securely. Cut to length and lead it to the
floor drain.
4. Replace the bucket in the unit.
NOTE: The bucket must be in place and securely seated for the
dehumidifier to operate. The drain hose must run down from the
dehumidifier to the floor drain.
Use the internal pump. Water can be automatically emptied into
a remote location by attaching the included pump hose.
1. Attach the pump hose to the hose connector by pushing the
tube fitting into the connector until it fits into place (should not
be able to remove the hose when pulled).
2. Position the hose discharge to the desired location.
3. Make sure the pump is activated. To activate the pump, press
and hold the Pump button for 3 seconds. The Pump indicator
light will flash then remain illuminated once the 3 seconds are
complete.
IMPORTANT: Make sure the condensate hose is properly
connected and is not kinked, bent or cracked as this may cause
water to flow onto the floor. Please ensure the bucket is empty
before putting the unit into pump mode. The bucket must also
be fully seated for the pump to work properly. Do not operate
the machine if the room temperature is 41°F or below.
NOTE: Maximum lift height is 16ft.
ENGLISH
1. Remove the bucket from the front of the unit.
2. Open the drain cover on the side of the unit.
49-5000429 Rev. 47
ENGLISH
USING THE DEHUMIDIFIER
Removing Collected Water (cont)
To Install Hose: Push in hose and gently pull to make sure it is
secure. Should not be able to be removed. You should hear a
“click” that lets you know the hose is inserted correctly.
Insert
To Release Hose: Press the blue button on top of the connector
attached to the dehumidifier and pull the hose out to remove. Be
sure to turn off the pump before removing the hose.
Press
Pull
Water Level
The dehumidifier will turn off automatically when the bucket
is full, or when the bucket is removed or not replaced in the
proper position.
NOTE: DO NOT kink or crimp hose, as it can block water flow.
The bucket must be replaced in the proper position for the
dehumidifier to work. The light will be on and the dehumidifier
will not run if the bucket is not in the proper position.
Bucket Operation
DO NOT remove the foam piece and magnet block in
the bucket assembly. If removed, the Dehumidifier will
not work properly.
When the coil is defrosted, the compressor or fan will
automatically restart and dehumidifying will resume.
849-5000429 Rev. 4
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.