Haier AS09GS1ERA, AS07GS1ERA, AS12GS1ERA, HUM09HC03-R2, HUM12HC03-R2 User Manual

...
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
Contents
AS07GS1ERA AS09GS1ERA AS12GS1ERA
PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION
MAINTENANCE CAUTIONS TROUBLE SHOOTING
2
3
5 9 10 11
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010535380
Parts and Functions
Indoor Unit
1
2
3
4
5
1
Inlet
2
Inlet grille
3
Outlet
4
Vertical blade
(adjust left and
5
Horizontal flap
right air flow)
6
7
8
(adjust up and down air flow.
Don't adjust it manually)
Please be subject to the actual produce purchased the above picture is just from your reference
8
6
7
Display board
Emergency
Switch
Air Purifying Filter
(inside)
Outdoor Unit
Remote controller
1
2
5
3
13
18
12
21
19
17
1. Mode display
Operation mode
Remote controller
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
ON/OFF
FAN
MODE
SWING
POWER/SOFT
TIMER
OCK
CL
LIGHT
SLEEP
SET
RE
SET
LOCK
COOL DRY
HEAT
AUTO
LO MED HIAUTO
10
9. CLOCK display
6
10.TEMP display
7 8
11. POWER ON/OFF button
9
12. MODE button
4
13. FAN button
11
14. HOUR button
15. SWING button
16. SLEEP button
17. LOCK button
15
23
Used to lock buttons and LCD
20
display.
14
18. TEMP.SETTIN button
16
19. SET / LIGHT button
22
20. TIMER button
21. CLOCK button Used to set correct time.
22. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
FAN
23. HOUR / POWER/SOFT button Used to set clock and timer setting. Every time the button is pressed, display changes as follows:
BLANK
SOFT
OWER
P
4
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Please be subject to the actual produce purchased the above picture is just from your reference
Clock set
Press CLOCK button, "AM" or "PM" flashes.
Press or to set correct time. Each press
or decrease 1min. If the
change quickly.
After time setting is confirmed,press SET,
button is kept pressed,time will
"AM "and "PM" stop flashing,while clock starts working.
CLOCK
LOCK
2
TIMER
LIGHT
SET
will increase
POWER/SOFT
SLEEP
RESET
Loading of the battery
Remove the battery cover;
1
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-sta rted type fluorescent lamp or change- over
type fluorescent lamp or room, the recei
ver is apt to be disturbed in receiving
so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation, please
remove the batteries and
Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
Load the batteries as illustrated.
2
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
3
is in line with th
wireless telephone is installed in the
Please change batteries.
reload several minutes later.
e" + "/"-";
the signals,
Operation
Base Operation
ON/OFF
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY
3.Select temp.setting
Press
Every time the button is pressed, temp.setting increase 1 rapidly
Every time the button is pressed, temp.setting decrease 1 decrease rapidly
Select a desired temperature.
button
o
C,if kept depressed, it will increase
o
C,if kept depressed, it will
4.Fan speed selection
Press FAN button. For each press, fan speed
changes as
Remote controller:
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
follows:
AUTO LO MED HI
TIMER
CLOCK
LIGHT
SET
LOCK
FAN
MODE
SWING
POWER/SOFT
SLEEP
RESET
FANHEAT
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room temperature
Above 23oC
Below 23
Designated temperature
26
o
C 23oC
Timer
Fan
speed
AUTO
AUTO
Operation
mode
COOL
HEAT
mode
o
C
No
No
emergency
operation switch
Pi
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
Test operation:
Test ope ration switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16 normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
o
C, do not use it in the
release
test operation
switch
Pi
Pi
Air Flow Direction Adjustment
1.Status display of air flow
Vertical flap
Pos.1 blank
Pos.4
2.Left and right air flow adjustment
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
Pos.2
(Auto swing)
Pos.3
(manual)
conditioner
Operation
Mode
AUTO
COOL
DRY
HEAT
FAN
Remote
Controller
Note
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation
according to room temperature to AUTO the air conditioner the fan speed according to room
In DRY mode , when room temperature becomes lower than temp.setting+2 intermittently at LOW speed regardless of FAN
setting.
In HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode AUTO is not available in setting is disabled. In FAN mode, sleep operation
is not available.
When FAN is set
automatically adjusts
temperature.
o
C, unit will run
but only in
FAN mode ,
FAN mode.
And temp.
'
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at air outlet if all vertical louvers are
right.
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
Note: When restart after remote turning off, the remote
controller will automatically
memorize the previous
set swing position.
adjusted to left or
mode ,
3
Operation
Sleep Operation
Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts,set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
O
1 higher than temp.setting.After another 1 hours,
C
temp.rises by 1 futher.The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room temperature won’t be too low for your sleep.
SLEEP operation starts SLEEP operation stops
Temp.setting
In HEAT mode
2.
1 hours after SLEEP mode starts,temp will become 2 lower than temp.setting.After another 1 hours,temp decrease by 2 futher.After more another 3hours,temp.rises
O
C
by 1 futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.
Temp.setting
O
C
Approx.6hrs
Rises 1
Rises 1OC
O
C
1 hr
1 hr
In COOL, DRY mode
O
C
Unit stop
O
Unit stop
C
In AUTO mode
3.
The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
When quiet sleeping function is set to 8 hours
5.
,
the quiet sleeping time can not be adjusted.
When TIMER function is set , the quiet sleeping function can't be set up. After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on, if the two modes are set up at the same time, either of their operation time is ended first, the unit will stop automatically, and the other mode will be cancelled.
Power Failure Resume Function
1. If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically, and 3 minutes later the compressor starts running.
2. Note to the power failure resume: press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds.
POWER/SOFT Operation
(1)
POWER Operation
When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medium speed of AUTO fan mode.
(2)
SOFT Operation
You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed
of AUTO fan mode.
Note˖ During POWER operation, in rapid HEAT or COOL modethe room
will show uniform temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation Press POWER/SOFT button again, POWER or SOFT
automatically takes low speed
disappears.
1 hr
Decreases 2OC
1 hr
SLEEP operation starts
Decreases 2
3 hrs
O
C
3 hrs
Rises 1OC
SLEEP operation stops
In HEAT mode
4
Loading...