Haier HSU-07LEK03, HSU-09LEK03, HSU-12HEK03, HSU-09LEK13, HSU-07HEK03 User Manual

...
Installation Manual of Room Air Conditioner
Read this manual before installation Explain sufficiently the operating means to the user according to this manual.
Necessary Tools for Installation
1.Driver cksaw
2.Ha
3.Hole core d
rill
Accessory parts
No. Accessory parts
1
2
3
4
5
6
Remote controller
R-03 d
Mounting plate
Drain hose
Steel nail, cement
4X25
Screw
Plastic cap
ry battery
4X50
Number of articles
1
2
1
1
6
4
5.
Torque wrench(17mm,22mm,26mm)
6.Pipe cutter ring tool
7.Fla fe
8.Kni
9.Nipper 12.Reamer
10.Gas leakage detector or soap-and-
water solution
11.Measuring tape
Drawing for the installation of indoor and outdoor units
mc5na
h
ter
Optional parts for piping
Mark
A
B
C
D
E
F
G
Parts name
Non-adhesi
Adhesi
ve tape
Saddle(L.S) with scr
Connecting elect for indoor and outdoor
Drain hose
Heating insulating material
Piping hole c
ve tape
ric cable
over
ews
m
o
r
e
t
h
a
n
1
0
c
m
om
Attention must be paid to the rising up of drain hose
m
o
r
e
t
h
a
n
1
0
c
m
A
1
1
4
1
1
10
11
7
8
9
Drain-elbow
Cover
Cushion
Pipe supporting plate
Connecting cable
Note:Cooling only units don't have Drain-elbow
No.0010518787
Arrangement of piping directions
Rear left
Below
Rear right
Right
Left
m
c
m
o
r
e
t
h
a
n
1
0
c
m
m
c
0
6
n
a
h
t
e
r
o
m
A
The marks from to in the figure are the parts numbers.
G
0
1
n
a
h
t
e
r
o
m
m
o
The distance between the indoor unit and the floor should be more than 2m.
C
D
E
r
e
t
h
a
n
1
5
c
m
HSU-09LEK13 HSU-12LEK13 HSU-07LEK03 HSU-07HEK03
140 140415
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-09LEK03 HSU-12LEK03 HSU-09HEK03 HSU-12HEK03
280
HSU-09LEK03/(DB) HSU-12LEK03/(DB)
HSU-18LEK13 HSU-108CH09 HSU-138CH09 HSU-12LEK13-M
HSU-18HEK03
Selection of pipe
500
140
Floor fixing dimensions of the outdoor unit (Unit:mm)
140
256
HSU-24LEK13 HSU-18LEK03/(DB)
HSU-24HEK03
583
113.5
113.5
Floor fixing dimensions of the outdoor unit (Unit:mm)
19 5. 3
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
For 07 09 108
Liquid pipe ( )
Gas pipe ( ) 9.52mm(3/8")
6.35mm(1/4")
For 12 18 138
6.35mm(1/4")
12.7mm(1/2")
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
B= 60mm
HSU-24HEK03 HSU-24LEK13
A=145mm
For 24
9.52mm(3/8")
15.88mm(5/8")
B= 60mm
30mm
HSU-12LEK13-M HSU-09LEK13
HSU-12LEK13 HSU-07LEK03 HSU-07HEK03
HSU-09LEK03/(DB) HSU-12LEK03/(DB)
HSU-09LEK03 HSU-12LEK03 HSU-09HEK03 HSU-12HEK03
HSU-108CH09 HSU-138CH09
A=145mm
30mm
HSU-18HEK03 HSU-18LEK13
HSU-18LEK03/(DB)
B=
A=145mm
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 60 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
Indoor side
Wall hole
60mm
(Section of wall hole)
2
G
Piping hole pipe
Outdoor side
Thickness of wall
60mm
30mm
Loading...
+ 2 hidden pages