Open the power switch 12 hours before the unit running.Do not cut off the power
when short time stop the unit (like one day and one night ),this is to protect the
compressor.
Do not block the air inlet and air outlet, otherwise the performance of the air
conditioner may be lowered and it will make the protection device act.
This is a cooling only unit,all the description about heating function is no meaning
for this unit.
Do not let the ID unit's outlet grill at downward position for a long time,when
the unit runing at cooling or drying mode.Otherwise ,the water may be fall off from
the outlet grill.
1
Parts and Functions
6
MODE
543
7
FANTEMPON/OFFTEMP
2
1
8
1.Power ON/OFF Button
Used for unit start or stop
2.FAN Button
Used to select fan speed:AUTO,LOW,MID,HIGH.
3.TEMP Setting Button
Used to set temperature. (Setting ranges: 16 C to 30 C)
4.MODE Button
Used to select operation mode: AUTO COOL DRY FAN HEAT
5.Operation MODE Display
Mode
AUTO
COOL
DRY
FAN
HEAT
Panel
6.FAN SPEED Display
AUTO(Flash)
LOWMID
HIGH
7.LOCK State Display
8.TEMPERATURE Display
Used to display set temperature and room temperature.
2
Operation points
Operation of air conditioner
When the ambient humidity is too high,
in COOLING or DEHUMIDIFYING
mode, there may be water dropped in the
air outlet.
3-minute protection function
If start the unit immediately only
after it is turned off, the compressor
will start after 3 minutes have
elapsed to protect the compressor.
MODEFANSWING
TEMP
CLOCK
SET
TIMER
SLEEP
FILTER RESET
RESET
ON/OFF
MODEFANSWING
TEMP
CLOCK
SET
TIMER
SLEEP
FILTER RESET
RESET
ON/OFF
Defrosting function
During Heating operation, when frost formed on the
heat exchanger of outdoor unit, the air conditioner
will defrost automatically for several minutes. During
defrosting, both the fan of indoor and outdoor unit
do not run. After finishing defrosting, the air
Anti-cold air blowing out
During Heating operation, after starting the
unit, the indoor fan motor will not rotate
MODEFANSWING
TEMP
CLOCK
SET
TIMER
SLEEP
FILTER RESET
RESET
ON/OFF
immediately to prevent cold air from blowing
out.
?
conditioner will automatically resume operation.
Change of fan speed
In COOLING mode, the air sending is set at AUTO,
when the indoor temperature is near the set temperature,
the fan speed will lower automatically.In HEATING
mode, when room temperature reaches the set temperature,
the compressor will stop running, and the fan will change
to LOW FAN or stop.
speed will change automatically.
In DEHUMIDIFYING mode, the fan
Hint
When the air conditioner
is in Heating mode, it
absorbs heat from
outside and release to
indoors. So the outdoor
temperature may affect
the Heating effect.
MODEFANSWING
TEMP
CLOCK
SET
TIMER
SLEEP
FILTER RESET
RESET
ON/OFF
3
Safety Precautions
Notice
The system should never be
used for any other purposes
than intended such as for
preservation of food, flora
and fauna, precision devices
or work of art.
It may cause deterioration of
the articles.
Do not install the system where the air
outlet may directly reach the flora and
fauna.
It will not be good for their health.
Do not use the power switch to turn on
or off the air conditioner.
ON
OFF
It may cause fire or
Creepage.
When operating the system simultaneously with a combustion
apparatus, indoor air must be ventilated frequently.*
Insufficient ventilation may cause the danger of lack of oxygen.
Do not put or use any
spray near the air
conditioner, and do not
directly spray to the air
conditioner.
Otherwise it may cause
fire.
Only use the proper specified fuse.
If use metal wire or copper wire to
replace the fuse, it may cause trouble
and fire accident.
Do not put the fire
devices in the places,
which the air from
the air conditioner
can directly blow.
It may cause the fire
devices cannot burn
completely.
When cleaning, please
stop the unit and cut off the power first.
Do not perform
cleaning, when the
indoor fan motor is
rotating in high
speed.
Do not use such equipment as a water heater,
etc., around the indoor unit
or the wire controller.
If the system is operated at the vicinity of such
equipment that generates steam, condensed
water may drip during cooling operation or it
may cause Creepage or short-circuit.
Do not put the water containers,
such as vase, on the unit.
If the water enters
into the unit and damages
the electric insulation material,
it may cause electric shock.
Safety precautions when moving, reinstalling and repairing the air conditioner
Warning
Do not refit the air conditioner.
When repair is needed, please
contact your dealer.
When moving the air conditioner to another
installation place, please contact the dealer
or the professional installer.
Improper repair may
cause water leakage,
electric shock and fire accident.
Improper moving and reinstallation may cause
water leakage, electric shock and fire accident.
Applicable ambient temperature range:
Cooling
Indoor
Outdoor
Maximum:
Minimum:
Maximum:
Minimum:
D.B / W.B
D.B / W.B
D.B / W.B
D.B
32 / 23
18 / 14
5221/ 32
4
Operation
AUTO, COOL , HEAT and DRY Operation
LOCK
MODE
1. Unit start
Press ON/OFF button,unit starts.
Previous operation status appears on LCD (except for TIMER,SLEEP and SWING setting)
2.Select operation mode
Press MODE button. At each press, operation mode changes as follows:
FANTEMPON/OFFTEMP
5
4
AUTO
FANHEATCOOLDRY
Then select AUTO run or select COOL operation or select DRY operation or select HEAT operation
or select FAN operation
3.Temperature setting
Press TEMP button.
Every time the button is pressed, temp. setting increases 1 C; if the button is kept pressed, temp. setting will
increase quickly.
Every time the button is pressed, temp. setting decreases 1 C, if the button is kept pressed, temp. setting will
decrease quickly.
Set proper temperature
4.Adjust FAN button
Press FAN button. At each press, fan speed changes as follows:
AUTO(Flash)
LOW
MIDHIGH
Air conditioner will run at the selected fan speed.
5. Unit stop
Press ON/OFF button,unit stops.
COOL operation starts
when room temp.is
higher than temp.
setting.
Temp. setting +2 C
Temp.setting
Ultra-low air flow
On reaching temp.setting
+2 C, unit will run in mild
DRY mode.
In FAN mode, the temperature setting is not displayed on LCD,and "Auto Fan" not available.
In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit will run intermittently
at LOW speed regardless of FAN setting. When room temperature is lower than temperature setting, unit will
only run FAN operation.
In HEAT mode,warm air will blow out after a short period of time due to cold-draft prevention function.
In Auto mode,unit will adjust fan speed according to room temperature automatically.
5
Operation
Fan Operation
LOCK
MODE
1.Unit start
Press ON/OFF button to start your air conditioner.
Previous operation status appears on LCD (except for TIMER, SLEEP, and SWING setting).
2.Select operating mode
FANTEMPON/OFFTEMP
4
Press MODE button. At each press, operation mode changes as follows:
AUTO
Then select FAN
FANHEATCOOLDRY
3. Adjust fan speed
Press FAN button. At each press, fan speed changes as follows:
Air conditioner will run at the selected fan speed.
4. Unit stop
Press ON/OFF button to stop unit.
About FAN mode
When the air conditioner runs in FAN mode, it is not possible to select
AUTO FAN or to set temperature.
5.
Warning:cooling only types are not with functions in heating mode.
6
Users Attention
Do not press tightly with the LCD part of
the wire controller to avoid damage of it.
Set proper room temperature
Not too low or high and make every people in the
room
feel
Cooling is
26~28¡
Heating is
18~23¡
comfortable.
Do not let the cold air blows directly to
human body for a long time and do not
make the room temperature drop too
low.
Otherwise, it may
cause uncomfortable
or bad to your health.
The airflow cannot directly blow
to the pets and plants.
Otherwise, pets
and plants
may be hurt.
The room should often ventilate.
After a long-time
of using air
conditioner, the
room must be
ventilated.
Do not keep the doors and windows
open
Otherwise, it
may lower the
efficiency of
the air conditioner.
If do not use the air conditioner
for a long time, it is necessary to
cut off power.
If do not cut
off power, the
Cut off
power
unit may consume
power. In order to protect the unit,
before using the air conditioner
again, turning on the power at least
12 hours in advance.
The windows should be hung
with curtains or blinds.
Do not let the sun
shine directly shine
in the room; do not
let the outdoor air
enter room.
The articles must keep dry cannot
be put under the indoor unit.
When the humidity
is over 80% or
the drainage
outlet is blocked,
the indoor unit may drop water.
Do not put articles around the
air inlet and outlet.
This kind of obstacle can lower the
efficiency of the air conditioner or
cause unit trouble.
Television, radio and acoustics, etc.
equipment should keep over 1m from
indoor unit and wire controller.
Otherwise, they may
disturb the image
and cause noise.
Do not put any drying
devices under
the indoor unit.
The heat may cause
the deformation of
indoor unit.
The air conditioner can only be used
in air conditioning. It can not be
used in other purpose.
Do not use the air conditioner in some
specific purpose, such as storage or
protect food, animals, plants, precise
instrument and
artwork,
otherwise,
the quality
of them may
be declined.
7
Maintenance
Disconnect power supplyDon't touch it with wet
hand
Remove air inlet grille
First cut off the power supply, then turn
the embedded part of air inlet grille
upwards, finally use cross-shaped
screwdriver to screw off the screw.
Air filter cleaning
Don't wash with hot water
or solvent to clean the unit
Use water or vacuum cleaner to clean it.
If it is extremely dirty, wash it with
neutral detergent or soap water.
Wash it with clean water and install
it after complete dry.
Caution:
Don't use hot water over 40 C,
as this may cause damage to air filter.
Wipe air filter carefully.
40¡
Indoor and outdoor cleaning
Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with
clean and soft cloth.
If air conditioner is very dirty, clean it with cloth
soaked in neutral detergent,then wipe off the
detergent with clean water.
Don't use water higher than 40 C , which will cause
discoloring and deformation.
Don't use insecticide or other chemical detergents.
8
40¡
Maintenance
After season maintenance
Let the unit run in Fan mode for half a day in a
fine weather to dry completely the unit inside.
Turn off the unit and pull out power plug.
There might be certain power consumption even
if unit is stopped.
Clean air filter and indoor unit, cover outdoor
unit after cleaning.
Before season maintenance
Check if there are obstacles at inlet
and outlet of indoor and outdoor unit,
whick will reduce unit efficiency.
Don't fail to attach air filter after making sure it is cleaned.
Dust will enter into unit causing damages or faults if it is running without air filter.
To protect compressor at start, please connect
external power supply to the unit 12 hrs prior
to starting. Also please keep the power supply
switch ON during the whole season.