Haier HPU-36C13, HPU-36H13, HPU-44C13, HPU-44H13 Operation & Installation Manual

Please read this operation manual before using the air conditioner.
No.0010578425
Operation & Installation Manual
CABINET TYPE AIR CONDITIONER
Please keep this manual carefully and safely.
HPU-36H13 HPU-36C13
HPU-44H13 HPU-44C13
Content
Operation
Cautions
Parts
Operation
Operation hints
Energy saving
Maintenance
Trouble shooting
When problems occur
Indoor & outdoor unit connection
Tools necessary
Installation procedures
5-12
13
14
17
20
1-2
3-4
15-16
18-19
21
22-27
Others
28
Cautions
1
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti­pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
2
The machine is adaptive in following situation
Applicable ambient temperature range:
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18
19.5 23 14 35 43 10 24 26 6 20 27 15 15 15 -­ 7 21 -7 6 15 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
˛´¶¨+
‰¡¿
˛´¶¨-
Parts
3
1
2
1
2
1
2
3
4
2
1
2
3
4
I n d o o r u n i t
Remote controller
Outlet grill Operation panel
Inlet grill
Air filter [inside the unit]
Outdoor unit
Inlet grill
Outlet grill
ON
OFF
TEMP
HEALTH
FAN
MODE
SLEEP
SWING
CLOCK
TIMER
SET
LOCKLIGHT
RESET
HEAT
SLEEP
POWER/SOFT
HEALTH AIRFLOW
FRESH
CODE
ON/OFF
MODE
FAN
TEMP +
TEMP -
HEALTH
SET
HUMI
TEMP
HEALTH
TIMER
SLEEP
TEMP
HUMI
SET
SLEEP
TIMER
HEALTH
ON/OFF
MODE
FAN
SET
TEMP
HUMI
HEALTH
TIMER
Parts
Manual Operation
MODE
CLOCK
Used to set correct time.
ON
OFF
TEMP
HEALTH
FAN
MODE
SLEEP
SWING
CLOCK
TIMER
SET
LOCKLIGHT
RESET
Power ON/OFF
Used for unit start and stop.
Used to select AUTO run, COOL, DRY,HEAT and FAN operation.
2
Battery Capacity display Display when the electric power of the battery is insufficient.
Power/Soft operation display
Humidifying display
Clock display
Temperature display Used to display the set temperature and room temperature.
Lock state display
Electric Heating display
2
HEAT
29
HEAT
Fresh Air state display
Select Auxiliary electric heater
1
1
3
3
4
5
TIMER
LOCK
Used to select TIMER ON, TIMER OFF, TIMER ON/OFF.
Used to lock buttons and LCD display.
4
5
6
7
8
9
10
11
12
LIGHT
SLEEP
Used to select sleep mode
HOUR
Used to set clock and timer setting.
RESET
Used to reset the controller back to normal condition.
SET
Used to confirm Timer and Clock setting.
HEALTH
Control the light up and go out of the control panel's background light source and control the switch of the buzzer.
Used to set Health operation function
FAN
Used to select fan speed: AUTO, LOW FAN, MED FAN, HIGH FAN.
Used to set UP/DOWN air sending and RIGHT/LEFT air sending direction.
SWING
6
7
8
9
10
11
12
13
13
14
15
16
17
18
19
21
22
21
23
24
25
26
23
24
27
25
26
29
28
20
B
A
28
27
22
4
Note: These models don't have the following related display and function
For some air conditioners , the function is not availed.
22 28
27
11 29
32
31
HEALTH AIRFLOW
FRESH
POWER/SOFT
30
CODE
33
POWER/SOFT Used to select HIGH or SOFT operation
30
FRESH Used to set fresh mode, the unit will
draw in fresh air
31
HEALTH AIRFLOW Used to set HEALTH AIRFLOW
function.The function is not available for these units UP/DOWN swing will not available if this button has been pushed, please press this button some times to cancel this mode
32
CODE Used to select Code A or B,
this manual is for Code A
33
32
Used to set temp.,temp. range:16 C~30 C
TEMP
Health display
Display when set Health operation function.
Timer ON/OFF display
Fan speed and air sending direction display
Swing direction display
Room temperature display
Sleep state display
LOW MID HIGH AUTO
14
15
16
17
18
20
19
5
1
2
3
Operation
Clock set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM"or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1 min . If the button is kept pressed, time will change quickly. After time setting is confirmed, press SET, "AM" and "PM" stop flashing, while clock starts working.
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit The distance between the signal transmission head and the receiver hole should be within 7m without any obsacles as well. Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signal so the distance to the indoor unit should be shorter.
MODE
SLEEP
SWING
CLOCK
TIMER
SET
LOCK
LIGHT
RESET
2R-03 dry batteries
M
IN
U
T
ES
HEAT
1
2
3
Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 5 mins.
Note:The waster batteries should be disposed properly,use two new same-type batteries when loading.
If the remote controller cant function normally or doesnt work at all,use a sharp-pointed item to press the reset key.
Hint:Remove the batteries in case unit wont be in usage for a long period. If there are any displays after taking-out just need to press reset key.
When throw away the waste batteries, please perform in accordance with the local regulation.
Loading of the battery
Slightly press " " and push down the cover. Load the batteries as illustrated. 2 R-03 dry batteries, (cylinder) Be sure that the loading is in line with the "+"/"-" pole request as illustrated. Put on the cover again.
HEATH AIRFLOW
FRESH
CODE
POWER/SOFT
Remote controller
LOW MID HIGH AUTO
Operation
2.
1.
Press ON/OFF button
Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode)
Press MODE button.
For each press, operation mode changes as follows:
5.
Remote controller
AUTO COOL DRY FAN HEAT
Press FAN
For each press, operation mode changes as follows:
Unit runs at the speed displayed on LCD.When fan speed is AUTO,
it is changed automatically,according to the indoor temperature.
Note: During Auto run operation, temp. setting will be shown in LCD display, unit will select heating, cooling or fan operation according to the room temp.
6.
6
Select temp. button
Press TEMP button Every time the button is pressed, temp. setting increases 1¡ Every time the button is pressed, temp. setting decreases 1¡ If the button is kept pressed, setting will increase or decrease quickly.
3.
In DRY mode, when room temp.becomes 2 C higher than temp. setting,unit will run intermittently at LOW speed regardless of FAN setting.
Ultra-low air flow
Temp.setting+2 C
Temp.setting
COOL operation starts when room temp. is higher than temp. setting.
On reaching 2 C higher than temp. setting,unitwill run in mild DRY mode.
ON
OFF
TEMP
HEALTH
FAN
MODE
SLEEP
SWING
CLOCK
TIMER
SET
LOCKLIGHT
RESET
2
6
HEAT
Then select AUTO run or select COOL operation or select DRY operation or select HEAT operation
AUTO
COOL DRY
FAN
ON
ON
1
3
5
3
Control panel
HEAT
TEMP+
TEMP-
The fan speed change of the control panel see page 12.
Press ON/OFF button Unit stops running.
4
(During Cooling ,Fan , Dehumidification etc. Operations ,this function cant be operated.) Press the button of HEAT ,remote controller & LCD display  ,this function start to runing.Press this button another time , remote controller & LCD display   will be disappears,this function stops.The Auxillary heating condition see the page 13 of this manual.
4.
Auxillary heating function(only Suit for the units with Auxillary heating function models)
HEALTH AIRLOW
FRESH
POWER/SOFT
CODE
1
5
3
3
2
4
ON/OFF
MODE
FAN
HEALTH
TEMPTEMP
TEMP
7
Operation
Fan Operation
3. Adjust fan speed
Press FAN button. At each press, fan speed changes as
follows:
Air conditioner will run at the selected fan speed.
4. Unit stop
Press ON/OFF button to stop unit.
Then select FAN
About FAN mode
When the air conditioner runs in FAN mode,
it is not possible to select AUTO FAN or to
set temperature.
Manual Operation
Remote-control unit
ON
OFF
TEMP
HEALTH
FAN
MODE
SLEEP
SWING
CLOCK
TIMER
SET
LOCKLIGHT
RESET
2
4
HEAT
1
3
AUTO
COOL
DRY
FAN
HEAT
Control panel
POWER/SOFT
CODE
HEATH AIRFLOW
FRESH
LOW
MED
HIGH
1.Unit start
Press ON/OFF button to start your air conditioner.
Previous operation status appears on LCD (except for
TIMER, SLEEP, setting).
2.Select operating mode
Press MODE button. At each press, operation mode
changes as follows:
AUTO
FANHEATCOOL DRY
1
4
2
ON/OFF
MODE
FAN
TEMP TEMP
HEALTH
3
TEMP
Loading...