Haier ESA415J, ESA418J Manual

0 (0)

ROOMAIRCONDITIONER

Use&CareGuide

ACONDICIONADORDEAIRE PARAHABITACIÓN

ManualdeUsoyCuidado

Model:

ESA415J ESA418J

No.0010532836

TABLEOFCONTENTS

AIR CONDITIONER SAFETY ........................................................

3

Changing Air Direction ................................................................

10

INSTALLATION REQUIREMENTS.................................................

3

Normal Sounds............................................................................

10

Location Requirements ...............................................................

3

AIR CONDITIONER CARE ...........................................................

10

Electrical Requirements ...............................................................

4

Cleaning the Air Filter .................................................................

10

INSTALLATION INSTRUCTIONS...................................................

5

Cleaning the Front Panel.............................................................

11

Unpack the Air Conditioner..........................................................

5

Annual Maintenance....................................................................

11

Wall Installation............................................................................

5

TROUBLESHOOTING ..................................................................

11

AIR CONDITIONER USE...............................................................

7

 

 

Starting Your Air Conditioner .......................................................

7

 

 

UsingtheRemoteControl...............................................................

9

 

 

ÍNDICE

SEGURIDAD DEL ACONDICIONADOR DE AIRE......................

13

REQUISITOS DE INSTALACIÓN.................................................

13

Requisitos de ubicación.............................................................

13

Requisitos eléctricos..................................................................

14

INSTRUCCIONES DE INSTALACIÓN.........................................

15

Desempaque el acondicionador de aire....................................

15

Instalaciones de pared ..............................................................

15

CÓMO USAR EL ACONDICIONADOR DE AIRE .......................

17

Cómo poner en marcha su acondicionador de aire...................

17

Cómo usar el control remoto .....................................................

19

Cómo cambiar la dirección del aire ...........................................

20

Sonidos normales.......................................................................

20

CUIDADO DE SU ACONDICIONADOR DE AIRE.......................

21

Limpieza del filtro de aire ...........................................................

21

Limpieza del panel frontal ..........................................................

21

Mantenimiento anual..................................................................

21

SOLUCIÓN DE PROBLEMAS......................................................

22

2

Plug into a grounded 3 prong outlet. Do not remove ground prong.
Do not use an adapter.

AIRCONDITIONERSAFETY

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”

These words mean:

DANGER

WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:

Do not use an extension cord.

Unplug air conditioner before servicing.

Use two or more people to move and install air conditioner.

SAVE THESE INSTRUCTIONS

INSTALLATIONREQUIREMENTS

LocationRequirements

A

IMPORTANT: Observe all governing codes and ordinances.

 

Check the location where the air conditioner will be installed.

 

Make sure you have everything necessary for correct installation.

 

The location should provide:

 

Grounded electrical outlet within 4 ft (122 cm) of where the

 

power cord exits the air conditioner.

 

NOTE: Do not use an extension cord.

 

Free movement of air in room to be cooled.

 

A large enough opening for the air conditioner.

 

Adequate wall support for weight of air conditioner. Air

 

conditioner weighs 102.3 lbs to 124.4 lbs (46.4 kg to 56.4 kg).

 

NOTE: Cabinet louvers must not be obstructed. Air must be able

A. Cabinet louvers

to pass freely through the cabinet louvers.

NOTE: Your model may differ from the one shown.

 

3

ElectricalRequirements

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located either on the side or back of the air conditioner cabinet or behind the front grille.

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power Supply

 

Cord

Wiring Requirements

208/230-volt (187 min. to 253 max.)

0 to 12 amps

Use on single outlet circuit only.

Recommended Grounding Method

This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3 prong grounding plug. The cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer.

It is the customer’s responsibility:

To contact a qualified electrical installer.

Power Supply Cord

NOTES:

Do not use the power supply cord as an off/on switch.

A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.

4

Haier ESA415J, ESA418J Manual

INSTALLATIONINSTRUCTIONS

UnpacktheAirConditioner

Remove Packaging Materials

Remove and dispose of/recycle packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.

Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner.

Handle the air conditioner gently.

Wall Installation

1, Using wood, 1”or more in thickness, build a wooden frame to

fit the casing/cabinet dimensions of the unit which you have

purchased.

2, Measure the outside width and the height of the frame to

determine the cutout dimensions necessary for the opening in

the wall. The depth of the frame will depend on the depth of

the wall. The finished frame must be set in the inside wall. The

frame has to be squared and leveled. Remember the frame has

to be nailed securely to the wall studs.

A

B

typical wood framing

A.Wall stud

B.Frame or back-up strip

3Now to install, insert the unit into the wall opening. Make sure that the cabinet is at least 1/2” inch inside the room. Also the side louvers should not be blocked. This is to have proper air circulation in and around the compressor.

4The cabinet should be tilted 1/4” outside so as to drain the excess dehumidified water.

5 Properly insulate any opening between the casing and the frame.

6Use external wall brackets if needed.

7 If needed,install molding around room side of cabinet. Seal small openings around window with gum-type sealer.

A

B

C

A.Wall

B.Level

C.Casing

CAUTION: If, after completing these steps, the unit appears to be loose or if you are unsure the unit is properly installed,contact a qualified installer.

5

Notes:Push to open the air outlet before using the air conditioner.

Adjust to desired position.

6

AIRCONDITIONERUSE

Operating your air conditioner properly helps you to obtain the best possible results.

This section explains proper air conditioner operation.

IMPORTANT:

If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This keeps the air conditioner from blowing a fuse or tripping a circuit breaker.

Do not try to operate your air conditioner in the Cool mode when outside temperature is below 61°F (16°C). The inside evaporator coil will freeze up, and the air conditioner will not operate properly.

 

 

 

 

StartingYourAirConditioner

 

 

 

 

 

Energy Saver—Fan runs only when cooling is needed. Press

 

 

 

 

 

SPEED to select High, Med or Low fan speed.

 

 

 

 

 

Because the fan does not circulate the room air continuously,

MODE

SPEED

TIMER

 

less energy is used, but the room air is not circulated as often.

 

Dehum—Dries the room. The air conditioner automatically

 

 

 

 

 

 

 

 

 

 

selects the temperature.

FAN

 

HIGH

ON

TEMP / TIME

NOTE:

 

 

 

 

 

 

 

COOL

 

MED

OFF

 

Dehum mode should not be used to cool the room.

ENERGY

LOW

 

 

In Dehum mode,Please do not operate the speed button.

SAVER

 

 

 

POWER

 

DEHUM

 

 

 

 

 

 

 

 

 

 

 

 

MODE

1. Remove the clear plastic film from the control panel.

FAN

 

 

 

 

 

2.Press POWER to turn on the air conditioner. The Power indicator light will turn on.

POWER

NOTE: When the air conditioner is plugged in, the LED display will show “88” for 3 seconds. After the air conditioner is turned on for the first time, the display will show the current room temperature and the fan is set to Low speed.

3.Select mode. See “Mode.”

4.Select fan speed. See “Fan Speed.”

5.Set temperature. See “Temperature.”

Mode

1.Press MODE until you see the indicator light glow for the desired setting.

2.Choose Fan, Cool, Energy Saver or Dehum.

Fan—Only the fan runs. Press SPEED to select High, Med or Low fan speed. The display shows the current room temperature.

Cool—Cools the room. Press SPEED to select High, Med or Low fan speed. Press the TEMP/TIME up or down arrow button to adjust the temperature.

COOL

ENERGY

SAVER

DEHUM

Fan Speed

1.Press FAN SPEED until you see the indicator light glow for the desired setting.

2.Choose High, Med or Low.

High—for maximum cooling

Med—for normal cooling

Low—for minimum cooling

SPEED

HIGH

MED

LOW

7

Temperature

Press the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME up arrow button, the temperature will go up 1ºF until it reaches 86°F (30°C).

NOTE: After 5 seconds, the display will show the current room temperature.

TEMP / TIME

Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C).

NOTE: After 5 seconds, the display will show the current room temperature.

Timer Delay

To set the Timer for a 1-hour to 24-hour delay until the air conditioner turns off (the air conditioner must be On):

1.Press TIMER. Timer OFF indicator light will flash. Display will show remaining hours before the air conditioner will turn off.

TIMER

ON

OFF

2.Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.

3.After 5 seconds, Timer OFF indicator light will remain on. Display will show the current room temperature.

To set the Timer to turn on the air conditioner, keeping previous settings:

1.Turn on the air conditioner.

2.Press TIMER. Timer On indicator light will flash. Display will show remaining hours before the air conditioner will turn on.

3.Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.

4.Timer On indicator light will remain on.

To set the Timer to turn on the air conditioner, changing the previous settings:

1.Turn on the air conditioner.

2.Adjust the mode to Fan, Cool, Energy Saver or Dehum.

3.For Fan, Cool or Energy Saver mode, adjust the fan speed to High, Med or Low.

4.Adjust the temperature between 61ºF and 86ºF (16ºC and 30ºC).

NOTE: In Fan mode, the temperature cannot be set.

5.Press TIMER. Timer On indicator light will flash. Display will show remaining hours before the air conditioner will turn on.

6.Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.

7.Timer On indicator light will remain on.

To clear Timer delay program:

NOTE: Air conditioner can be either on or off.

1.Press TEMP/TIME once after it has been programmed. Display will show remaining time.

2.While the display is showing the remaining time, press TIMER untill Timer indicator light turns off.

To see or change the remaining time (in hours):

Timer Off :

1.Press TEMP/TIME once after it has been programmed.

Display on the air conditioner control panel will show remaining time.

2.While the display is showing the remaining time, press

the TEMP/TIME up or down arrow button to increase or decrease the time.

3.After 5 seconds, the display on the air conditioner control panel will show the current room temperature.

Timer On :

1.Display on the air conditioner control panel will show remaining time.

2.While the display is showing the remaining time, press the TEMP/TIME up or down arrow button to increase or decrease the time.

8

Loading...