Haier AB182ACBAC, AB182ACNAC, AU182AABAC, AU182AANAC, HBU-18CL03/R1 Operation Manual

...
OPERATION MANUAL
No.0010571466
CASSETTE AIR CONDITIONER
AB182ACNAC AU182AANAC (HBU-18CL03/R1) AB182ACBAC AU182AABAC (HBU-18HL03/R1)
1
CAUTIONS
..................................................................................
THE NAME OF EACH PART AND ITS FUNCTION
...............
INTRODUCTION TO SPARE PARTS
................................
REMOTE CONTROLLER OPERATION
.................................
GUIDE TO OPERATION
.......................................................
AIR FLOW DIRECTION ADJUSTMENT PROCEDURE
.......
FOR COMFORTABLE USE
....................................................
CARE AND MAINTENANCE
..............................................
WARNING OPERATION
...................................................
2-3
4
5-6
7
8-12
13-15
16 17-19 20-24
2
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
3
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit
by yourself.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Indoor unit
Unit indication section (Power, Timer, Run, Pump)
Remote controller signal receiver The signal is received.
Back up switch
Swing louver
Air blows out from here. Air flow direction is adjusted.
Wireless Remote controller
Air inlet grille Takes in the indoor air.
Air filter Removes dust or dirt out of the inlet air. (In the Air inlet grille)
Air inlet
Outdoor unit
Air outlet
Compressor(inside of unit)
4
THE NAME OF EACH PART AND ITS FUNCTION
C
INTRODUCTION TO SPARE PARTS
5
Buttons and display of the remote controller.
Operation
CLOCK
MODE
SWING
Power ON/OFF
TEMP
FAN
SLEEP
SET
HOUR
RESET
LOCK
TIMER
Used for unit start and stop.
Used to set auto fan direction.
Used to select AUT O run, COOL,DRY,HEAT and FAN operation.
Used to set correct time.Used to set correct time.
Used to select TIMER ON, TIMER OFF, TIMER ON/OFF.
Used to lock buttons and LCD display.
Used to reset the controller back to normal condition.
Used to set clock and timer setting.
Used to confirm Timer and Clock settings.
Used to select sleep mode.
Used to select fan speed: LO, MID, HI, AUTO
Used to select your desired temp.
Cautions: On cooling only unit, heating mode is not available. After replacing batteries, press ON/OFF, and display becomes as follows: Operation mode: AUTO, Temp: 24 C Timer mode: No, Fan speed: AUTO
Note:
1. The above information is the explanation of the displayed information therefore varies with those displayed in actual operation.
2. This type only has the relevant function and display as indicated in the above figure.
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK TIMER
LOCK RESET
AUTO
ON OFF
AM PM
AM PM
C
INTRODUCTION TO SPARE PARTS
6
Hints
LO
MID
HI
AUTO
AUTO
Buttons and display of the remote controller.
Operation
DRY
COOL
AUTO
SWING
FAN SPEED
SLEEP
Clock set
TIMER ON
TIMER OFF
LOCK
CLOCK
TEMP.
SIGNAL SENDING
FAN OPERATION
HEAT
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes.
Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET , "AM "and "PM" stop flashing, while clock starts working.
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK TIMER
LOCK RESET
AUTO
ON OFF
AM PM
AM PM
REMOTE CONTROLLER OPERATION
7
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2R-03 batteries, resetting key (cylinder)
Remove the battery cover :
Slightly press " " and push down the cover.
Load the battery :
Be sure that the loading is in line with the " + " / " - " pole request as illustrated.
Put on the cover again Confirmation indicator :
In disorderation, reload the batteries or load the new batteries after 5 mins.
Note :
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.
Hint :
Remove the batteries in case unit won't be in usage for a long period. If there is any display after taking-out just need to press reset key.
TEMP
SWING
FAN
ON
OFF
MODE
SLEEP
SET
CLOCK TIMER
LOCK RESET
AM
Loading...