Haier AB142ACBAA, AU142AFABA, AB142ACMAA, AB142ACNAA, AU142AFBHA Operation Manual

...
No.0010570833 C
CASSETTE AIR CONDITIONER
Operation Manual
AB142ACMAA AU142AFMAA (HBU-14C03) AB142ACAAA AU142AFABA (HBU-14H03) AB142ACNAA AU142AFNBA (HBU-14CA03/R1) AB142ACBAA AU142AFBBA (HBU-14HA03/R1)
Please read this manual carefully before using the air conditioner Please keep this manual properly for future use
051128*23*******
Contents
Cautions
...........................................................................................
Main points of operation
..................................................................
Name of Each part
..........................................................................
Safety cautions
................................................................................
Gaide to operation
........................................................................
Maintenance
.....................................................................................
Trouble shooting
..........................................................................
When trouble happens
.....................................................................
Customer Need to know
.................................................................
Installation Tools
..............................................................................
Installation Procedures
................................................................
Installation Procedures,Check and Test Run
....................................
Air Purging Method ( To use vacuum pump) ....................................
1-2 3-4 5-7 8-9
10-16
17
18-20
21 22 23
24-31
32 33
CAUTIONS
1
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
2
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Cooling
Heating
Indoor
Maximum: Minimum:
D.B / W.B D.B /
D.B
Outdoor
Maximum: Minimum:
D.B
D.B
Indoor
Maximum: Minimum:
D.B
Outdoor
Maximum: Minimum:
43 C/ 26 C
D.B / W.B 24 C/ 18 C
20 C
27 C
15 C
18 C/ 14 C
32 C/ 23 C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T. 3.15A /250V AC.
CAUTIONS
4. The wiring method should be in line with the local wiring standard.
5. All the cables shall have got the European authentication certificate.
6.The waste battery shall be disposed properly .
7.The indoor unit installation height is at least
2.5m.
8.The appliance must be installation that the plug should be easily accessible after installation.
9. The power plug should be self-provided and it should have got the European authentication certificate.
D.B / W.B -7 C/ -8 C
3
Main points of Operation
Operation of Air Conditioner
When the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode.
3-minute Protection Function
If restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect the machine.
Variation of Fan Speed
If fan speed in auto mode, it will automatically lower when the room temperature close to the setting temperature in cooling mode.
In heating mode,the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops.
In Dry mode,fan speed will be automatically varied.
Remote Control:
There is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a far­away place.
4
Main points of Operation
Prevent Cool Air Blowing Off
In heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off.
Defrosting Function
In heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defrost a few minutes. During defrosting, both indoor and outdoor fan will stop running. When defrosting finished, air condi­tioner will automatically back to running.
Hints
The air conditioner absorbs heat form outside and releases inside when in heating mode, therefore the outside environmental temperature will affect heating effects.
Power Failure Compensation(to be applied for a necessary situation):
After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press the “sleeping” button on the remote controller 10 times within 5 seconds,and after the buzzer rings 4 times,the air conditioner will enter the state of power failure compenstation.
Cancel Method:Press the “sleeping” button on the remote controller 10 times within 5 seconds, and after the buzzer rings 2 timer,the power failure compensation mode will be cancelled.
Note: When a power failure suddenly occurs during the air conditioner si working after the power after the power failure compensationis set,if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being res­ umed after the power is supplied again, or press the “ Switch On/Off ” button after the power comes again.
Wait a minute
Defrosting Running
5
Indoor unit
Swing louver
(Air flow direction can be adjusted by using the SWING button on the remote controller)
Electrical Components Case
Air Inlet Grille
Air Filter
(Inside of the Inlet Grille)
Air Outlet (blow out hot air when cooling and cool air when heating)
Air Inlet (back)
Conneting pipe and electrical wiring
Name of Each Part
outdoor unit
Air Inlet (side)
5
Name of Each Part
Remote controller
1.TEMP Setting Button
(Used to set temperature, setting ranges: 16 C to 30 C)
In Up/Down function,for controlling up and down filter.
2.SWING Button
Press once auto swing, press again the swing louver fixed on the present swing position.
3.Power ON/OFF Button (used for unit
start and stop) After power on, the LCD of remote contr-
oller will display the previous operation state (except for TIMER,SLEEP and SW­ING state).
4.Operation MODE
Used to select operation mode. Every time press MODE button,operation mode
changes according ot hte following order:
5.CLOCK Button
Used to set correct time.
AUTO
FAN
HEAT
COOL
DRY
6.TIMER Button
Used to select TIMER mode:TIMER ON,TIMER OFF, TIMER ON/OFF.
(Note: if time of TIMER ON is the same as TIMER OFF,TIMER ON/OFF cannot be set)
7.LOCK Button
8.RESET Button
Used to sharp article press this button can reset the remote controller back to normal condition when it in malfunction state.
9.Battery Loaded Indication
10.HOUR Adjustment
Used to set clock and timer setting
11.SLEEP Button
(The clock must be corrected before set sleep function)
Used to set sleep mode.
12.SET Button
Used to confirm TIMER and CLOCK settings.
13. FILTER Button
Used to set up/down function of filter.
14.FAN Button
Used to select fan speed:LOW,MID,HIGH,AUTO.
NOTE: 1.Single cooling air conditioner does not have the displays and functions related to heating.
2.This kind of unit does not have the following related functions and displays:
16
19
20
22
23
24
25
27
TEMP
SWING
FAN
MODE
ON
OFF
SLEEP
SET
FILTER
CLOCK
TIMER
LOCK
RESET
AUTO
OFFON
C
23
21
22
20 19 18
17 16
10
11
12
14
9
8
7
6
5
4
1
31
30
29
28
26
25
24
2
3
13
15
27
32
Used to lock operation button and LCD display contents: after press this button, other button are out of function, lock state display appears; press again,cancel lock state and lock state display disappeared.
7
Clock Set
Name of Each Part
Display when healthy run function is set.
15.TIMER OFF Display
16.HUMIDIFICATION Display
17.TEMPERATURE Display
18.LOCK State Display
19.BATTERY Energy Display
Display when in low battery to remind customer to change the battery.
20.STRONG/QUITE Run Display
21.SIGNAL SENDING Display
22.NEW AIR Display
23.ELECTRICAL HEATING Display
24.HEALTH Display
25.SLEEP State Display
26.Operation MODE Display
AUTO RUN
COOL RUN
DRY RUN
HEAT RUN
FAN RUN
27.COMFORTABLE RUN Display
28.FAN SPEED Display
29.AUTO SWING Display
30.TIMER Display
31.FILTER Display
32.TIMER ON Display
Remote Controller’ Operation
The distance between the signal transm­ission head and the receiver hole should be within 7m without any obstacle as well.
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1.Press CLOCK button,clock indication of “ AM “ or “PM” flashes.
2.Press or to set correct time,each press will increase or decrease 1 min. If the button is kept pressed, time will increase or decrease quickly.
3.After time setting is confirmed,press “SET” , AM or PM stop flashing, while clock starts working.
Note:AM means morning and PM means afternoon.
Don’t throw the controller,prevent it from being damaged.
When in use, put the signal transmission head directly to the receiver hole on the indoor unit
When electronic-strated type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter.
Loading of the battery (load the batteries as illustrated)
Remove the battery cover
Load the battery
Put on the cover again
Installing the cover is opposite to removing it
Confirmation indicator
If no indication after press ON/OFF button,reload the batteries.
Note:
AUTO
LO MID
HI
AUTO
Use two new same-typed batteries when loading. If the remote controller can’t run normally during
operation ,please remove the batteries and reload them few minutes later that will be ok
If the display of remote controller is faded(someti­mes run abnormally),which indicates no battery,so please change the batteries
Hint:
Remove the batteries in case unit will not be in usage for a long period.if there is any display after taking-out just need to press reset button with a sharp article
First slightly press the position marked with and push down the cover,then as shown in the figure:holding the upper part of the remote con­troller with the left hand and the right hand slightly grasps the battery box cover and forces on the arrow direction to remove the cover.
SLEEP
SET
TIMER
LOCK
RESET
MODE
FILTER
CLOCK
1
Be sure that the loading is in line with the “ + ” “ - ” pole request as illustrated on the botton of the box.
2
3
8
Safety Cautions
Below are listed four kinds of Safety Cautions and Suggestions:
Be sure to conform with the following important Safety Cautions. The Safety Cautions should be at hand so that they can be checked at any time when needed. If the air conditoner is transferred to the new user, this manual should be as well transferred to the new user.
Incorrect operations may result in severe consequences of death or serious injures.
WARNING:
Incorrect operations may result in injures or machine damages; in some cases may cause serious consequences.
CAUTION :
: It must be strictly prohibited where marked with “ Prohibited ”, otherwise may result in machine damages or endanger the user’personal safety.
This information can ensure the correct operation of the machine.
INSTRUCTION:
Carefully read the following information in order to operate the air conditioner correctly.
WARNING
If any abnormal phenomena are found (e.g. smell of firing),please cut off the power supply immediately, and contact the dealer to find out’ the handling method.
When need maintenance and repair,call dealer to handle it.
Don’t put figures or any other things into the inlet/outlet and swing louver while the conditi­oner is in operation
Call the dealer to take measures to prevent the refrigerant from leaking.
Switch off
In such case,to continue using the air conditioner will damage the conditioner,and may cause electrical shock or fire hazard.
Incorrect maintenance and repair may cause water leak, electrical shock and fire hazard.
Because the high-speed fan is very dangerous and may cause injures.
The leaked refrigerant over certain density may cause oxygen deficient.If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage
When air conditioner is removed and reinstalled dealer should be responsible for them.
Incorrect installation may cause water leaking, electrical shock and fire hazard.
Don’t dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous witch may harm human beings.
After a long time use of air conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
9
Safety Cautions
WARNING
No goods or nobody is permitted to be placed on or stand on outdoor unit.
Don’t clean air conditioner with water.
The falling of goods and people may cause accidents.
Don't operate the air conditioner with damp hands.
Otherwise will be shocked.
Only use correct type fuse.
May not use wire or any other materials replacing fuse,othe­rwise may cause faults or fire accidents.
Don’t place any burning unit in the airflow of air conditioner,which may cause incomplete combustion
No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident.
Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Otherwise may cause shock.
Connect earthing wire.
Earthing wire should not be connected to the gas pipe, water pipe,lightning rod or phone line,incorrect earthing may cause shock.
Use discharge pipe correctly to ensure efficient discharge.
In correct pipe usage may cause water leaking.
Air conditioner can’t be be installed in the environment with inflammable gases.
The inflammable gases near to air conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
When use the fumigating insecticide don’t operate air conditioner.
Otherwise the poisonous chemicals may settle in air conditioner, which harm the health of chemical-allergic people.
It easily causes electrical shock without circuit breaker.
Not permitted when running