Haier AB092ACBJA, AB122ACBJA, AB142ACBFA, AB142ACBJA, AB182ACBFA Operation And Installation Manual

...
No.0010576976 B
CASSETTE TYPE AIR CONDITIONER
Operation & Installation Manual
AB092ACBJA AB122ACBJA AB142ACBJA AB182ACBJA AB142ACBFA AB182ACBFA
Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
051220***,*AB092/122ACBIA*** **AB092/122ACBJA*******
Contents
Cautions
.............................................................................................
Main Points of Operation
...................................................................
Part Name
...........................................................................................
Safety Precautions
..............................................................................
Maintenance
......................................................................................
When Trouble Happens
.....................................................................
Customer Need-to-know
...................................................................
Installation Tools
...............................................................................
Installation Procedures
......................................................................
Troubleshooting ................................................................................
Failure code
.........................................................................................
Check and Test Run
..........................................................................
1-2 3-4
5 6-7 8-9
10 11
12 13-20 21-22
23
24
Cautions
1
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier .
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner .
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
All these valuable materials may be taken to a waste collecting center and used again after
adequate recycling. Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
2
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver .
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 -5 24 26 -­ 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 10 24 26 -­ 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
AB142/182ACBFA:
Other Instructions
*****
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on PC board is broken, please change it with the type of T3.15A /250V AC.
4. Use copper wire only . The connecting cable should be H05RN-F 3G(2.5mm2+H05RN-F 1x 0.75mm2. The power cable should be H05RN-F 3G 2.5mm2.All the cables shall have got the European authentication certificate.
***************
AB092/122ACBJA AB142/182ACBJA:
051220*********
1. The waste battery should be disposed properly . When throw away the waste batteries, please perform in accordance with the local regulation.
2. The indoor unit installation height is at least
2.5m.certificate.
5. The power cord should be self-provided and it should have got the Local authentication certificate.
6. The air breaker should be all-pole switch. and the distance between it's two connecters should no less than 3mm.
7. Air conditioner must use special power supply system (above 20A), and qualified electrician makes wiring and fixing according to wiring regulations specified in national standard.
8. In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together .
9. A leakage breaker must be installed.
10. Connection method is Y-connection .If the power cord is damaged, it must be replaced by professional people of manufacturer or its maintenance department or similar to avoid dangers.
11. The air breaker and the power switch should installed the conveniently reachable place for user . AB142ACBF A AB182ACBFA: Attention: As a result of poor conditions of the electrical MAINS, shortly voltage drops can appear when starting the EQUIPMENT . This can influence other equipment (et.Blinking of a lamp). If the MAIN-IMPEDANCE Zmax<
0.3970617HM, such disturbance are not expected. In case of need , you may contact your local supply authority for further information.
3
Main Points of Operation
Operation of Air Conditioner
When the environmental humidity is heavy, water will be dripped from the air outlet in cooling or drying mode.
3-minute Protection Function
If restarting the unit immediately after unit stops, the compressor will start only 3 minutes later to protect the machine.
Diferent Fan Speed
If fan speed is in auto mode, it will automatically lower when the room temperature is close to the setting temperature in cooling mode.
In heating mode,the compressor stops when the room temperature is at setting temperature and fan turns into low speed or stops.
In Dry mode,fan speed will be automatically adjusted.
Remote Control:
There is a telecommunication interface for remote control on the operation panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a distant away place.
4
Main Points of Operation
Anti-cold Blowing Off
In heating mode,the indoor fan will not run immediately after the unit starts up, which will the cold air being blow out.
Defrosting Function
In heating mode, when frost is formed on the outdoor heat exchanger, the air conditioner will automatically defrost for few minutes. During defrosting, both indoor fan and outdoor fan will stop running. When defrosting finishes, air condi­tioner will automatically be back to running.
Hints
The air conditioner absorbs heat form outdoor and releases to indoor when in heating mode, therefore the outdoor environmental temperature will affect heating efficiency.
Auto-restant function(to be applied for a necessary situation):
After the auto-restant function is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press the ìSLEEPî button on the remote controller 10 times within 5 seconds,and after the buzzer sounds 4 times, the air conditioner will enter the state of auto­ restant function
Cancel Method:Press the ìSLEEPî button on the remote controller 10 times within 5 seconds, and after the buzzer sounds 2 times, the auto-restant function will be cancelled.
Note: When a power failure suddenly occurs during the air conditioner is working after the auto-restant function is set,if the air conditioner will not be used for a long time, please shut off the power supply to prevent its operation from being resumed after the power is supplied again, or press the ì ON/OFF î button after the power come again.
Defrosting Running
Wait a minute
5
Indoor unit
Part Name
outdoor unit
Swing louver
(Air flow direction can be adjusted by using the SWING button on the remote controller)
Air Inlet Grille
Air Filter
(Inside of the Inlet Grille)
Operating Control Panel
Air inlet
Air outlet
Drain hose
Connecting piping and electrical wiring
Remote receiver Compressor Lamp TIMER Lamp OPERATION Lamp Power Lamp Emergency switch
1 2 3 4
5
COMP TIMER OPER POWER
1 2 3 4 5
Operating Control Panel
6
6
051220**********
6
Below are listed four kinds of Safety Precautions and Suggestions:
Be sure to conform with the following important Safety Precautions. The Safety Precautions should be at hand so that they can be checked at any time when necessary. If the air conditoner is transferred to the new user, this manual should be as well transferred to the new user.
Safety Precautions
Incorrect operations may result in severe consequences of death or serious injures.
WARNING:
Incorrect operations may result in injures or machine damages; in some cases may cause serious consequences.
CAUTION :
: It must be strictly prohibited where being marked with ì Prohibited î, otherwise may result in machine damages or endanger the usersípersonal safety.
This information can ensure the correct operation of the machine.
INSTRUCTION:
Carefully read the following information in order to operate the air conditioner correctly .
WARNING
If any abnormal phenomena are found (e.g. smell of firing),please cut off the power supply immediately, and contact the dealer to find outí the handling method.
When the unit needs maintenance and repair,call dealer to handle it.
Donít put figures or any other things into the inlet/outlet and swing louver while the conditi­oner is in operation
Call the dealer to take measures to prevent the refrigerant from leaking.
Switch off
In such case,to continue using the air conditioner will damage the conditioner,and may cause electrical shock or fire hazard.
Incorrect maintenance and repair may cause water leak, electrical shock or fire hazard.
Because the high-speed fan is very dangerous and may cause injures.
The leaked refrigerant over certain density may cause oxygen deficient.If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage
When air conditioner is removed and reinstalled dealer should be responsible for them.
Incorrect installation may cause water leaking, electrical shock and fire hazard.
Donít dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous witch may harm human beings.
After air conditioner has been used for a long time, the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
7
WARNING
No goods or nobody is permitted to be placed on or stand on outdoor unit.
Donít clean air conditioner with water.
The falling of goods and people may cause accidents.
Don't operate the air conditioner with damp hands.
Otherwise will be shocked.
Don't use incorrect type fuse.
May not use wire or any other materials replacing fuse,othe­rwise may cause faults or fire accidents.
Donít place any burning unit in the airflow of air conditioner,which may cause incomplete combustion
No inflammable spray fluid should be permitted to be placed or used near air conditioner,otherwise may cause fire accident.
Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Otherwise may cause shock.
Connect earthing wire.
Earthing wire should not be connected to the gas pipe, liquid pipe,lightning rod or phone line,incorrect earthing may cause shock.
Use discharge pipe correctly to ensure efficient discharge.
Incorrect pipe usage may cause water leaking.
Air conditioner canít be be installed in the environment with inflammable gas.
The inflammable gas near air conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
When useing the fumigating insecticide donít operate air conditioner.
Otherwise the poisonous chemicals may damage air conditioner, and will harm the health of chemical-allergic people.
It easily causes electrical shock without circuit breaker.
Not permitted when running
Safety Precautions