Haier AB142ACBBA, AU142AFBBA, HBU-14HC03/R1 Operation Manual

No.0010571987
CASSETTE AIR CONDITIONER
Operation Manual
AB142ACBBA AU142AFBBA (HBU-14HC03/R1)
Contents
Cautions
...........................................................................................
Main points of operation
..................................................................
Name of Each part
..........................................................................
Safety cautions
................................................................................
Gaide to operation
........................................................................
Maintenance
.....................................................................................
Trouble shooting
..........................................................................
When trouble happens
.....................................................................
Customer Need to know
.................................................................
Installation Tools
..............................................................................
Installation Procedures
................................................................
Installation Procedures,Check and Test Run
....................................
Air Purging Method ( To use vacuum pump) ....................................
1-2 3-4 5-6 7-8
9-14
15
16-18
19 20 21
22-31
32 33
CAUTIONS
1
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings Before starting the air conditioner, read
the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
2
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Cooling
Heating
Indoor
Maximum: Minimum:
D.B / W.B D.B /
D.B
Outdoor
Maximum: Minimum:
D.B
D.B
Indoor
Maximum: Minimum:
D.B
Outdoor
Maximum: Minimum:
43 C/ 26 C
D.B / W.B 24 C/ 18 C
20 C
27 C
15 C
18 C/ 14 C
32 C/ 23 C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T. 3.15A /250VAC.
CAUTIONS
4. The wiring method should be in line with the local wiring standard.
5. All the cables shall have got the European authentication certificate.
6.The waste battery shall be disposed properly .
7.The indoor unit installation height is at least
2.5m.
8.The appliance must be installation that the plug should be easily accessible after instal­ lation.
9. The power plug should be self-provided and it should have got the European authenti­ cation certificate.
D.B / W.B -7 C/ -8 C
3
Main points of Operation
Operation of Air Conditioner
When the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode.
3-minute Protection Function
If restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect the machine.
Variation of Fan Speed
If fan speed in auto mode, it will automatically lower when the room temperature close to the setting temperature in cooling mode.
In heating mode,the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops.
In Dry mode,fan speed will be automatically varied.
Remote Control:
There is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a far­away place.
Note: Air conditioner has installed detector,in order to add group control function,Can refer to Centralized Controller installation and operation manual.
4
Main points of Operation
Prevent Cool Air Blowing Off
In heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off.
Defrosting Function
In heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defrost a few minutes. During defrosting, both indoor and outdoor fan will stop running. When defrosting finished, air condi­tioner will automatically back to running.
Hints
The air conditioner absorbs heat form outside and releases inside when in heating mode, therefore the outside environmental temperature will affect heating effects.
Power Failure Compensation(to be applied for a necessary situation):
After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press the ìsleepingî button on the remote controller 10 times within 5 seconds,and after the buzzer rings 4 times,the air conditioner will enter the state of power failure compenstation.
Cancel Method:Press the ìsleepingî button on the remote controller 10 times within 5 seconds, and after the buzzer rings 2 timer,the power failure compensation mode will be cancelled.
Note: When a power failure suddenly occurs during the air conditioner si working after the power after the power failure compensationis set,if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being res­ umed after the power is supplied again, or press the ì Switch On/Off î button after the power comes again.
Wait a minute
Defrosting Running
5
Indoor unit
Swing louver
(Air flow direction can be adjusted by using the SWING button on the remote controller)
Electrical Components Case
Air Inlet Grille
Air Filter
(Inside of the Inlet Grille)
Air Outlet (blow out hot air when cooling and cool air when heating)
Air Inlet (back)
Conneting pipe and electrical wiring
Name of Each Part
outdoor unit
Air Inlet (side)
6
Name of Each Part
1.ON//OFF button
2.Temperature display
3.Clock display
4.Timer ON/OFF display
5.Humidity display
6.Air filter cleaning display
When there is too much duct collected on the air inlet, the wire controller will show this display to remind the user to clean the air inlet. After cleaning and installation, just press the air filter reset button
7.Super/Soft operation display
8.Fan speed display
low
Mid
High
Auto
AUTO
9.Health state display
10.Fresh air state display
Note:
1.Cooling only type air conditioner does not have thedisplay and functions related with heating.
2.This model does not have the following related display and function 5 7 9 10 11 15 .
Calibration of clock
When turning on the unit for the first time, the clock should be calibrated. The method of calibration is:
1.Press ìClockî button, the Clock display ìAMî ìPMî will flash.
2.Press or to adjust time. For each press, the time will increase or decrease 1 minute. If depressing the button, the time will increase or decrease rapidly.
3.After confirming the time, press ìSetî button, ìAMî or ìPMî will stop flashing, the clock will begin to work.
11.Humidifying state display
12.Sleep state display
13.Network control display
14.Working mode display
AUTO RUN
COOL RUN
DRY RUN
HEAT RUN
FAN RUN
15.Electric heating display
16.Operation mode button
Used to set working mode: Auto,Cooling,Dry,Heating,Fan
17.Fan speed button
Used to set fan speed: Low Fan, Mid Fan, High Fan, Auto
18.Temperature Setting button
Used to set temperature,
19.Clock button
Used to calibrate the time of timer and clock
20.Setting button
Used to confirm the time of timer and clock
temperature range: 16 C~30 C
21.Sleep button
Used to confirm the time of timer and clock
22.Time Adjusting button
Used to adjust the time of timer and clock
23.Reset button
When the wire controller appears abnormal condition, use asharp­pointed article topress this button to make the wirecontroller resume normal
24.Air Filter Reset button
After cleaning the air inlet, press thisbutton, the unit can start to operate
25.Timer button
Used to set the mode of timer
26.Lock state display
2
3
5
6
7
8
9
10
11
12
13 14 15 16 17
4
AM PM
AM PM
C
AUTO
%
SET
ROOM
ON OFF
MODE
FAN SWING
TEMP
CLOCK SET
TIMER SLEEP
RESET
FILTER RESET
18 19
20 21 22 23
24 25
26
1
ON/OFF
7
Safety Cautions
Below are listed four kinds of Safety Cautions and Suggestions:
Be sure to conform with the following important Safety Cautions. The Safety Cautions should be at hand so that they can be checked at any time when needed. If the air conditoner is transferred to the new user, this manual should be as well transferred to the new user.
Incorrect operations may result in severe consequences of death or serious injures.
WARNING:
Incorrect operations may result in injures or machine damages; in some cases may cause serious consequences.
CAUTION :
: It must be strictly prohibited where marked with ì Prohibited î, otherwise may result in machine damages or endanger the userípersonal safety.
This information can ensure the correct operation of the machine.
INSTRUCTION:
Carefully read the following information in order to operate the air conditioner correctly.
WARNING
If any abnormal phenomena are found (e.g. smell of firing),please cut off the power supply immediately, and contact the dealer to find outí the handling method.
When need maintenance and repair,call dealer to handle it.
Donít put figures or any other things into the inlet/outlet and swing louver while the conditi­oner is in operation
Call the dealer to take measures to prevent the refrigerant from leaking.
Switch off
In such case,to continue using the air conditioner will damage the conditioner,and may cause electrical shock or fire hazard.
Incorrect maintenance and repair may cause water leak, electrical shock and fire hazard.
Because the high-speed fan is very dangerous and may cause injures.
The leaked refrigerant over certain density may cause oxygen deficient.If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage
When air conditioner is removed and reinstalled dealer should be responsible for them.
Incorrect installation may cause water leaking, electrical shock and fire hazard.
Donít dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous witch may harm human beings.
After a long time use of air conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
8
Safety Cautions
WARNING
No goods or nobody is permitted to be placed on or stand on outdoor unit.
Donít clean air conditioner with water.
The falling of goods and people may cause accidents.
Don't operate the air conditioner with damp hands.
Otherwise will be shocked.
Only use correct type fuse.
May not use wire or any other materials replacing fuse,othe­rwise may cause faults or fire accidents.
Donít place any burning unit in the airflow of air conditioner,which may cause incomplete combustion
No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident.
Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Otherwise may cause shock.
Connect earthing wire. Earthing wire should not be
connected to the gas pipe, water pipe,lightning rod or phone line,incorrect earthing may cause shock.
Use discharge pipe correctly to
ensure efficient discharge. In correct pipe usage may cause water leaking.
Air conditioner canít be be installed in the environment with inflammable gases.
The inflammable gases near to air conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
When use the fumigating insecticide donít operate air conditioner.
Otherwise the poisonous chemicals may settle in air conditioner, which harm the health of chemical-allergic people.
It easily causes electrical shock without circuit breaker.
Not permitted when running
9
Guide to Operation
Fan Operation
Unit will selected the desired fan speed
ROOM
MODE
FAN SWING
TEMP
CLOCK SET
TIMER SLEEP
RESET
FILTER RESET
1
4
2
3
ON/OFF
1.Unit start
Press ON/OFF button, unit starts. Previous operation status appears on LCD (except for TIMER ,SLEEP, and SWING setting). Power indicator light up.
2.Select operation mode
Press MODE button. For each press,operation mode changes as follows:
3. Adjust fan speed
Press FAN button.For each press,fan speed changes as follows:
4. Unit stop
Press ON/OFF button,unit stops.
AUTO FANHEAT
COOL
DRY
Then select FAN
LOW
MID
HIGH
The wire controller only shows the clock and room temperature.
FAN operation refers the air conditioner does not perform COOLING and HEATING operation, but air sending operation. In this mode, the air conditioner cannot perform AUOT FAN operation, and does show the temperature value on the wire controller.
About FAN operation
AM
Loading...