Haier AB092FCBIA, AB092FCAIA, AB142FCAIA, AB142FCBIA, AB182FCAIA Operation And Installation Manual

...
No.0010575379
CASSETTE TYPE AIR CONDITIONER
Indoor unit Operation & Installation Manual
Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
Contents
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P.R.China Web Site: http://www.haier.com
Cautions
...........................................................................................
Main Points of Operation
................................................................
Name of Each Part
............................................................................
Safety Cautions
................................................................................
Maintenance
...................................................................................
When Trouble Happens
......................................................................
Customer Need-to-know
....................................................................
Installation Procedures
.................................................................
Trouble Shooting..........................................................................
Installation Procedures,Check and Test Run
.....................................
1-2 3-4
5 6-7 8-9
10
11 12-16 17-18
19
Cautions
1
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
The air breaker should be all-pole switch. and the distance between it's two connecters should be no less than 3mm.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
2
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T3.15A /250VAC.
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 -5 24 26 -­ 20 27 15
14.5 -- -­ 7 21 -15 6 15 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
2
2
19
Other Instructions
1.Configuration of power supply
Air conditioner must use special power supply system (above 20A), and qualified electrician makes wiring and fixing according to wiring regulations specified in national standard.
In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together. A leakage breaker must be installed. Parameters of power supply: H07RN-F 3G 2.0mm
2
Connection method is Y-connection .If the power cord is damaged, it must be replaced by professional people of manufacturer or its maintenance department or similar to avoid dangers.
2.Pipe cutting and expanding
Must remove burrs if cut pipes with pipe cutter. Expand flare after insert the pipe expander.
Installation check and test run
Require customers to use air conditioner according to the operation manual. The items checked during test run,please mark in
No gas leakage on the pipe joint ? How about the thermal insulation of the pipe joint: Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly? Is the wiring of indoor and outdoor unit secured firmly? Is the drainage hose arranged correct? Is the earthing wire connected firmly? Is the power supply voltage conformed to the electrical regulation? Any noise? Is the display on the control board (LCD) correct? Cooling normal? Does the indoor temperature regulator work normally? For the power supply L shall be connected to the live wire. N shall be connected to the neutral wire.
Shall be connected to the earth wire.
The person who has completed this installation shall be requested to conduct a test operation for check:
Is the temperature adjuster working normally? Does the location for installation conform to requirements?
Winding up with Protective Plastic T ape
The connection pipes, drain pipe, and the connection wires shall be wound up with PVC tape.
Notes: The connection pipes shall also be wound up with insulating material to preserve the temperature. The airing direction shall be from bottom to top.
Trial Operation
Correct
Incorrect
Deflection
Crack occurs
Broken
Incomplete
Over outward
A
Pipe expander
Liquid pipe
Gas pipe
Diameter of pipe
Dimension A (mm)
1.0~1.2
1.4~2.2
6.35mm (1/4î)
12.7mm (1/2î)
Installation Procedures,Check and T est Run
4. The wiring method should be in line with the local wiring standard.
5. Use copper wire only. The connecting cable should be H05RN-F 4G 0.75mm . The power cable should be H05RN-F 3G 2.5mm . All the cables shall have got the European authentication certificate.
6. The waste battery shall be disposed properly.
7. The indoor unit installation height is at least
2.5m.
8. The appliance must be installation that the plug should be easily accessible after installation.
9. The power plug should be self-provided and it should have got the Local authenti­ cation certificate.
18
**?
ON
OFF
Air does not blow or the fan speed cannot be changed during drying.
In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting
During heating,indoor fan is still running even unit is stopped.
To get ride of the excess heat, indoor fan will continue running for a while after unit autom­atically stops.
Water or vapor generated from the outdoor unit during heating.
This happens when the frost accumulated on the outdoor unit is removed (during defrosting operation).
Defrosting operation
Please check the following things about your air conditioner before making a service call.
Unit fails to start.
Is the power supply switch on ?
Power supply switch is not in ON position.
Is city supply power normal ?
Is the earth leakage breaker in action ?
Be sure to turn off the power supply switch immediately and contact the sales dealer.
Trouble Shooting
3
Main points of Operation
Operation of Air Conditioner
When the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode.
3-minute Protection Function
If restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect the machine.
Variation of Fan Speed
If fan speed in auto mode, it will automatically lower when the room temperature close to the setting temperature in cooling mode.
In heating mode,the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops.
In Dry mode,fan speed will be automatically varied.
Remote Control:
There is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a far­away place.
4
Main points of Operation
Prevent Cool Air Blowing Off
In heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off.
Defrosting Function
In heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defrost a few minutes. During defrosting, both indoor and outdoor fan will stop running. When defrosting finished, air condi­tioner will automatically back to running.
Hints
The air conditioner absorbs heat form outside and releases inside when in heating mode, therefore the outside environmental temperature will affect heating effects.
Power Failure Compensation(to be applied for a necessary situation):
After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press the ìsleepî button on the remote controller 10 times within 5 seconds,and after the buzzer rings 4 times, the air conditioner will enter the state of power failure compenstation.
Cancel Method:Press the ìsleepî button on the remote controller 10 times within 5 seconds, and after the buzzer rings 2 times, the power failure compensation mode will be cancelled.
Note: When a power failure suddenly occurs during the air conditioner is working after the power failure compensation is set,if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being resumed after the power is supplied again, or press the ì Switch On/Off î button after the power comes again.
Defrosting Running
Wait a minute
17
The followings are not malfuncition
Hua
Hua
Trouble Shooting
Water flowing sound is heard
When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som­etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction.
Cracking sound is heard
It smells.
This is caused by heat expansion or contra­ction of plastics
Air blown out from the indoor unit sometimes smells. The smell results from smells of furniture, paint , tobacco absorbed by indoor unit.
During operation, white fog comes out of indoor unit.
When in COOL or DRY mode, a thin water fog can be seen blown out of unit ,this is the condensed fog because the suddenly cooled indoor air is blown out.
Automatically switch into FAN mode during cooling.
To prevent frost from being accumulated on the indoor unit heat exchanger, it sometimes auto­matically switched into the FAN mode,but it will soon back to the cooling mode.
The air conditioner cannot be restarted soon after it stops. Air conditioner does not start?
This is because of the self-protection function of the system, therefore,it cannot be restarted for about three minutes after it stops.
Please wait for three minutes
In function of code B ,set and cancel Auto restart function by using of "SWING" button.
Note:
Series
remote controller units please press the remote controller botton "CODE" to choose the program of code "B"
5
Indoor unit
Name of Each Part
Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller)
Air Inlet Grille
Air Filter (Inside of the Inlet Grille)
Operating Control Panel
Electrical box
16
Piping Connection
(1) Dimension of connecting pipe
Fit the nut on and fasten
(2) The maximum length and drop height of connecting pipe
The maximum length is 20m The maximum drop height is 10m. To ensure the efficiency ,Pipes shall be as short as possible.
Cautions for piping connection
Do not twist or deform the connecting pipe. Do not mix dusts. The bending radius shall be as large as possible.
Both gas pipe and liquid pipe shall be heat insulation. No leakage in the flare.
(3) Piping connection
Connecting method
Smear refrigerant oil on the joints of piping and flare. The bending radius shall be as large as possible. Align the pipe center when fastening, and tighten the nut, as shown in the figure. Pay attention to not mix foreign matters such as sands in.
Diameter of Pipe
Liquid Pipe 6.35mm Gas Pipe 12.7mm
Tighten Torque (N. m)
11.8
49.0
If not aligned ,tighten the nut by force will damage the nut that result in gas leakage
12.7mm
6.35mm
Gas pipe Liquid pipe
Spanner
Spanner
Joint
Nut
Installation Procedures
6
Below are listed four kinds of Safety Cautions and Suggestions:
Be sure to conform with the following important Safety Cautions. The Safety Cautions should be at hand so that they can be checked at any time when needed. If the air conditoner is transferred to the new user, this manual should be as well transferred to the new user.
Safety Cautions
Incorrect operations may result in severe consequences of death or serious injures.
WARNING:
Incorrect operations may result in injures or machine damages; in some cases may cause serious consequences.
CAUTION :
: It must be strictly prohibited where marked with ì Prohibited î, otherwise may result in machine damages or endanger the userípersonal safety.
This information can ensure the correct operation of the machine.
INSTRUCTION:
Carefully read the following information in order to operate the air conditioner correctly.
WARNING
If any abnormal phenomena are found (e.g. smell of firing),please cut off the power supply immediately, and contact the dealer to find outí the handling method.
When need maintenance and repair,call dealer to handle it.
Donít put figures or any other things into the inlet/outlet and swing louver while the conditi­oner is in operation
Call the dealer to take measures to prevent the refrigerant from leaking.
Switch off
In such case,to continue using the air conditioner will damage the conditioner,and may cause electrical shock or fire hazard.
Incorrect maintenance and repair may cause water leak, electrical shock and fire hazard.
Because the high-speed fan is very dangerous and may cause injures.
The leaked refrigerant over certain density may cause oxygen deficient.If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage
When air conditioner is removed and reinstalled dealer should be responsible for them.
Incorrect installation may cause water leaking, electrical shock and fire hazard.
Donít dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous witch may harm human beings.
After a long time use of air conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
15
6. Installation of Ornament Panel
Install ornament panel on indoor unit
(1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the ornament panel. (2) Fasten the screws to make the height difference between the two sides of indoor unit less than 5mm.
(3) First fix it with screws temporally. (4) Fasten the two temporally fixing screws and other two, and tighten the four screws. (5) Connect the wires of synchro-motor. (6) Connect the wire of signal. (7) If no response of remote controller,check whether the wiring is correct,restart remote controller
10 seconds after shut off power supply.
Limits of panel board installation
(1)Install the panel board in the direction shown in the figure. (2)The incorrect direction will result in water leakage, meanwhile swing and signal receiving are displayed that cannot be connected.
Installation Procedures
7
WARNING
No goods or nobody is permitted to be placed on or stand on outdoor unit.
Donít clean air conditioner with water.
Safety Cautions
The falling of goods and people may cause accidents.
Don't operate the air conditioner with damp hands.
Otherwise will be shocked.
Only use correct type fuse.
May not use wire or any other materials replacing fuse,othe­rwise may cause faults or fire accidents.
Donít place any burning unit in the airflow of air conditioner,which may cause incomplete combustion
No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident.
Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Otherwise may cause shock.
Connect earthing wire.
Earthing wire should not be connected to the gas pipe, water pipe,lightning rod or phone line,incorrect earthing may cause shock.
Use discharge pipe correctly to ensure efficient discharge.
In correct pipe usage may cause water leaking.
Air conditioner canít be be installed in the environment with inflammable gases.
The inflammable gases near to air conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
When use the fumigating insecticide donít operate air conditioner.
Otherwise the poisonous chemicals may settle in air conditioner, which harm the health of chemical-allergic people.
It easily causes electrical shock without circuit breaker.
Not permitted when running
14
4. Installation of water drainage pipe
(1) Install water drainage pipe
Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm )
Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming.
If downward slope of drainpipe cannot be made,lifting pipe shall be installed. Keep a distance of 1-1.5m between suspending bolts, to make water hose straight.
Use the drainage hose and clip provided with unit. Insert water pipe into water plug until it reaches the white tape.
Tighten the clip until head of the screw is less than 4mm from hose. Wind the ddrainage hose to the clip using seal pad for heat insulation. Insulate drainage hose in the room.
5. Cautions for the water drainage lifting pipe
Installation height of water drainage lifting pipe shall be less than 280mm There should be a right angle with unit ,300mm from unit.
< Note >
The slope of water drainage hose shall be within 75mm , make the drainage plug not to bear excessive force.
If several water hoses join together, of as per following procedures.
Specifications of the selected drainage hoses shall meet the requirements for the unit running
Slope below 1/100
Connection drainage hose with a T-joint
100mm ¸over
slope over 1/100
1-1.5m
Clip
Tape(white)
Draingage hose
Large size seal pad
4mm below
(accessory)
Clip
Clip
Water drainage lifting pipe
Suspending bracket
Drainage hose
280mm unter
500mm below
220mm
300mm below
1-1.5m
220
Drainage hose
75mm below
500mm below
Installation Procedures
8
Maintenance
Clean the unit
Turn off the power supply switch
Do not touch with wet hand.
Do not use hot water or volatile liquid
Button the 2 fixing fastener as shown in the figure by arrow , till the air inlet grille be pulled off.
Clean the air filter
Clean the air filter with water or vacuum cleaner. Use the detergent or neutral soapy water if the air filter is too dirty. Then rinse the air filter with water,and reinstall after drying.
Caution:
Do not clean the air filter with hot water over 40 C, otherwise may damage the filter. Sweep the filter carefully.
Clean indoor unit
Clean with hot wet cloth and neutral detergent, then wipe with dry cloth.Do not use too hot water (over 40 C) which may result in fading and deforming. Do not use insecticide and chemical washing agent.
lockhole
lug two corners of the filter
Filter rim
fixing fastener
Lug two corners of the filter at the same time,pull off the filter.
Button fixing fastener
lock parts
lock parts portal
Outward drawable filter
take down the air inlet grille
13
(3) Install a suspending bolt To support the unit weight ,anchor bolt should be used in the case of
already exists ceiling. Fow new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field. Before going on installing, adjust space to ceiling.
3. Installation of indoor unit
In case of no ceiling Install unit temporally Put suspending bracket on the suspending bolt to hang the unit up. Be sure to use nut and washer at both end of the breaket to secure firmly.
After installation on the ceiling
(1) Adjust unit to its right position (Refer to preparation for installation-(1)) (2)Check that unit is horzontal.
Put suspending bracket on the suspending bolt to hang the unit up.Be sure to use nut and washer at both end of the bracket to secure it firmly.
Water pump and floating switch is installed inside indoor unit,check four corners of the unit for its lever using horizontal comparator or PVC tube with water.(If unit is tilting against the direction of water drainage,problem may occur on floating water leakage.)
In the case of ceiling already exists
(1)Install unit temporally
(2)Adjust the height and position of the unit. (3)Proceed with procedure (4) of " In the case of no ceiling "
Nut (Prepare in feild)
Washer (Prepared in feild)
Suspending bolts
Fasten (double nuts)
Insert Washer fixing pad
(prepared in feild)
[ secure the washer firmly]
leveler
Polythene pipe
Note: All the above mentioned parts shall be prepared in feild, the diameter of suspending bolt is M10
<Installation Example>
Ceiling
Roof
Anchor bolt Long nut or thread
Suspending bilt M10
50 ~150mm
Installation Procedures
ON
OFF
9
Seasonal Reserve
Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well.
Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop.
Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.
Pre-season Care
See that there is no obstacle blocking the air inlet and air outlet of both indoor and outdoor unit to avoid reduce the working efficiency.
Be sure to install the air filter, ensure that the air filter is not dirty. Otherwise may result in machine damages or cause malfunciton due th dust inside the unit
To protect compressor when start in HEAT mode, please cut in the power supply switch 12 hours before starting run,furthermore, always keep the power supply switch on during the using senson.
Post-season Care
Maintenance
12
1.Selection of Installation Place
(1) Place above the ceiling where have enough space to arrange the unit. (2) Place where the drainage pipe can be arranged well. (3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked. (4) Do not expose the unit to the place with heavy oil or moisture (e.g.kitchen and workshop). (5) Do not set the unit in the place where destructive gas (such as sulfuric acid gas) or pungent
gas (thinner and gasoline) concentrates and retains. (6) Place strong enough to support the unit weight.
(7) No expensive articles such as television and piano below indoor unit. (8) Enough space for maintenance. (9) Place more than 1m away from television and radio to avoid disturbing television and radio. (10) Easy for maintenance.
2.Installation Preparation
(1) Position of ceiling opening between unit and suspending bolt (front view of unit).
(2) Prepare all piping (refrigerant,water drainage )and wires (connection wire of remote controller, indoor unit connection wires) to the indoor unit before installation in order to connect indoor unit immediately after installation.
Overlap between ceiling and ornament panel shall be 25mm
Suspending bolts
Ceiling
Ornament panel
150mm
320mm
60mm
Air outlet
Air outlet
Air inlet
2.5m Over (do not exceed 2.7m)
Distance between
suspending bolts 535mm
Indoor unit 570mm Ceiling opening 650mm Ornament panel 700mm
Indoor unit 570mm
Ceiling opening 650mm
Ornament panel 700mm
Installation Procedures
1.5m
1.5m
0.31m
H
Loading...