Haag-Streit AT 910, AT 900 Instructions For Use Manual

1
DEUTSCHENGLISHFRANÇAISITALIANOESPAÑOLNEDERLANDS
PORTUGUÊS
SVENSKA
© HAAG‑STREIT AG, 3098 Koeniz, Switzerland – HS‑Doc. no. 1500.7006000.04240 – 24. Edition / 2018 – 04
INSTRUCTIONS FOR USE Applanation tonometer
AT 900® / AT 870
24. Edition / 2018 – 04
01-IFU_AT900-7006000-04240_eng.indd 1 03.05.2018 10:11:09
2
DEUTSCHENGLISH FRANÇAIS ITALIANO ESPAÑOL NEDERLANDS
PORTUGUÊS
SVENSKA
© HAAG‑STREIT AG, 3098 Koeniz, Switzerland HS‑Doc. no. 1500.7006000.04240 24. Edition / 2018 04
INSTRUCTIONS FOR USE Applanation tonometer
AT 900® / AT 870
24. Edition / 2018 – 04
Introduction
Thank you for choosing a HAAG-STREIT device. Provided you comply carefully with the regulations in this instructions for use, we can guarantee the reliable and unproblematic use of our product.
Purpose of use
The manual operated Goldman tonometer is an appliance that serves to measure intraocular pressure, according to the Goldman method. The measuring of the pres‑ sure requires to maintain a uniform applanation of the surface of the cornea. It is specially indicated in Glaucoma disease.
Contraindication
There is no absolute contraindication for execution of the tonometry. Appropriate professional assessment and caution are necessary.
WARNING!
Applanation tonometry may only be conducted by appropriately trained
and qualied medical personnel.
WARNING!
Read the instruction manual carefully before commissioning this pro­duct. It contains important information regarding the safety of the user and patient.
NOTE!
Federal law restricts this device to sale by or on the order of a physician or licensed practitioner.
01-IFU_AT900-7006000-04240_eng.indd 2 03.05.2018 10:11:10
3
DEUTSCHENGLISHFRANÇAISITALIANOESPAÑOLNEDERLANDS
PORTUGUÊS
SVENSKA
© HAAG‑STREIT AG, 3098 Koeniz, Switzerland – HS‑Doc. no. 1500.7006000.04240 – 24. Edition / 2018 – 04
1. Safety .......................................................................4
1.1 Areas of application of the device ..........................................................4
1.2 Ambient conditions .................................................................................4
1.3 Shipment and unpacking .......................................................................4
1.4 Installation warnings .............................................................................4
1.5 Operation, environment .........................................................................4
1.6 Disinfection ............................................................................................4
1.6.1 Cleaning and disinfection of the measuring prism .................................5
1.6.2 Visual inspection of the measuring prisms for damages ........................5
1.6.3 Service life of reusable measuring prisms .............................................6
1.6.4 Tonosafe ................................................................................................6
1.6.5 Monthly device checks ...........................................................................6
1.7 Warranty and product liability .................................................................6
1.9 Description of symbols ...........................................................................6
2. Introduction ..............................................................6
2.1 Overview ................................................................................................7
3. Appliance assembly / installation ..........................7
3.1 AT 900 Model R .....................................................................................7
3.2 AT 900 Model T ......................................................................................7
3.3 AT 900 Model BQ ...................................................................................7
3.4 Tonometer AT 870 ................................................................................. 7
3.5 Which slit lamp with which tonometer ....................................................7
3.6 Description of models ............................................................................8
4. Commissioning ........................................................8
5. Operation .................................................................8
5.1 Astigmatism ...........................................................................................8
5.2 How pressure is measured ....................................................................8
5.3 Preparing the patient ..............................................................................8
5.4 Patient instructions .................................................................................9
5.5 Preparation of slit lamp and tonometer ..................................................9
5.6 Measuring correctly ................................................................................9
5.7 Sources of error ...................................................................................10
5.7.1 Wrong distance to patient ...................................................................10
5.7.2 Position too far to the right / left ...........................................................10
5.7.3 Position too high / low .......................................................................... 11
5.7.4 Incorrect pressure ................................................................................ 11
6. Technical data ........................................................12
6.1 Applanation tonometer AT 900 .............................................................12
6.2 Applanation tonometer AT 870 .............................................................12
7. Maintenance ...........................................................12
7.1 Repairs .................................................................................................12
7.2 Cleaning and disinfection .....................................................................12
7.3 Checking the Tonometer AT 900 .......................................................... 14
7.4 Checking the Tonometer AT 870 .......................................................... 15
A. Appendix ................................................................17
A.1 Accessories – Original HAAG‑STREIT measuring prisms ...................17
A.2 Accessories – Tonosafe ....................................................................... 17
B. Legal regulations ...................................................17
C. Classication .........................................................17
D. Disposal ..................................................................17
E. Standards ...............................................................17
Contents
01-IFU_AT900-7006000-04240_eng.indd 3 03.05.2018 10:11:10
4
DEUTSCHENGLISH FRANÇAIS ITALIANO ESPAÑOL NEDERLANDS
PORTUGUÊS
SVENSKA
© HAAG‑STREIT AG, 3098 Koeniz, Switzerland − HS‑Doc. no. 1500.7006000.04240 – 24. Edition / 2018 – 04
1. Safety
DANGER!
Failure to comply with these instructions may result in material damage or pose a danger to patients or users.
WARNING!
These warnings must absolutely be complied with to guarantee safe operation of the product and to avoid any danger to users and to patients.
NOTE!
Important information: please read carefully.
1.1 Areas of application of the device
The device is intended for use in doctor's practices, hospitals, and optometrists' and opticians' premises.
1.2 Ambient conditions
Transport: Temperature
Air pressure Relative humidity
from
from from
−40°C
500 hPa 10%
to
to to
+70°C
1060 hPa 95%
Storage:
Temperature Air pressure Relative humidity
from from from
−10°C 700 hPa 10%
to to to
+55°C 1060 hPa 95%
Use:
Temperature Air pressure
Relative humidity
from from
from
+10°C 800 hPa
30%
to to
to
+35°C 1060 hPa
90%
1.3 Shipment and unpacking
Before you unpack the appliance, check whether the packaging shows traces of
incorrect handling or damage. If this is the case, notify the transport company that has delivered the goods to you. Unpack the equipment together with a represen‑ tative of the transport company. Make a report of any damaged parts. This report must be signed by you and by the representative of the transport company.
Leave the device in the packaging for a few hours before unpacking it (conden‑
sation).
Check the appliance for damage after it is unpacked. Return defective appliances
in the appropriate packaging.
Store packaging material carefully, so that it can be used for possible returns or
when moving.
NOTE!
Check the calibration of the instrument before rst use according to the
instructions in section 7.3.
1.4 Installation warnings
WARNING!
Do not modify this equipment without authorization of the manufacturer. Installation and repairs may only be performed by trained specialists.
NOTE!
• When performing assembly on appliances from other manufacturers, the connecting dimensions of the diverse tonometer models are to be taken into account!
• Check: Are the connection parts properly positioned (tonometer on the slit lamp, measuring prisms)?
1.5 Operation, environment
WARNING!
• The examination is to be performed at the medical professional’s discretion and consideration in cases of active infections and lesions of the eye. Certain conditions could falsify measured values and the procedure may interfere with the patient’s condition.
• Use only original HAAG‑STREIT Goldmann tonometer measuring prisms or the sterile disposable measuring prisms TonoSafe from HAAG‑STREIT.
Strong magnetic elds may falsify the measurement results.
NOTE!
This appliance must only be operated by qualied and trained personnel.
The owner is responsible for their training.
1.6 Disinfection
NOTE!
The device does not need to be disinfected. For more information on cleaning, please refer to the 'Maintenance' chapter.
01-IFU_AT900-7006000-04240_eng.indd 4 03.05.2018 10:11:10
5
DEUTSCHENGLISHFRANÇAISITALIANOESPAÑOLNEDERLANDS
PORTUGUÊS
SVENSKA
© HAAG‑STREIT AG, 3098 Koeniz, Switzerland – HS‑Doc. no. 1500.7006000.04240 – 24. Edition / 2018 – 04
1.6.1 Cleaning and disinfection of the measuring prism
DANGER! The measuring prisms are made of PMMA. Please take note of the
following restrictions:
- Do not disinfect with alcohol
- Do not clean with acetone
- Do not disinfect using UV radiation
- Do not sterilise using steam or ethylene oxide
- Do not expose to temperatures above 60°C
WARNING! Reusable measuring prisms are not shipped disinfected and must
becleanedanddisinfectedbeforetheirrstuseinaccordance
with the separate instructions for use on the cleaning and dis­infection of tonometer measuring prisms, contact glasses, and DESINSET (HS item no. 7220375).
Preparation may only be conducted by qualied and trained person‑ nel. Their training is the responsibility of the user.
• Appropriate professional assessment and caution are necessary.
• Only use clean, undamaged, and disinfected measuring prisms!
• Please observe the separate instructions for use on the cleaning and disinfection of tonometer measuring prisms, contact glasses, and DESINSET (HS item no. 7220375)!
• The operator shall be liable in the event of non‑observance of the cleaning and disinfecting process!
NOTE!
• Only those disinfectants tested by HAAG‑STREIT for material com‑ patibility may be used for disinfection.
• The current list is enclosed with every tonometer and measuring prism, and can also be found on the HAAG‑STREIT AG website (www.HAAG‑STREIT.com).
• The separate instructions for use on the cleaning and disinfection of tonometer measuring prisms, contact glasses, and DESINSET is to be consulted regarding the exact functioning, concentration, working times, and idle times.
• Improper preparation can result in the transmission of diseases to the patient and user as well as damage to the measuring prism.
• Residue from cleaning agents and disinfectants may irritate and burn the patient’s eye.
• As a rule, the measuring prisms may be prepared together with each other, but not with any other products.
In order to achieve a efcient disinfection and storage of tonometer measuring prisms, we recommend the use of our DESINSET. For a selection of cleaning and disinfection agents please refer to the instructions for use “Cleaning and disinfection” and to our “List of Dis‑
infectants”. The efcacy of the disinfectants on tonometer measuring
prisms must be guaranteed by the user or the reprocessing responsi‑ ble person with the validation of their own disinfection process.
• The validation report is available from HAAG‑STREIT on request.
• A summary of the validation report can be found on the HAAG‑STREIT website (www.HAAG‑STREIT.com).
• The operator accepts liability for the use of other disinfectants.
• Single‑use prisms must be replaced after every examination ‑ see separate instructions for use.
• The instructions for use referred to above, the brief instructions on the disinfection of tonometer measuring prisms and additional information can be found on our website www.HAAG‑STREIT.com at any time.
1.6.2 Visual inspection of the measuring prisms for damages
DANGER! Never use damaged measuring prisms.
Prior to every use, the contact surface of the measuring prism must be inspected for contaminants or damage (scratches, cracks and sharp edg‑ es). This must be performed with a slit lamp microscope at 10x to
16xmagnication.
01-IFU_AT900-7006000-04240_eng.indd 5 03.05.2018 10:11:10
6
DEUTSCHENGLISH FRANÇAIS ITALIANO ESPAÑOL NEDERLANDS
PORTUGUÊS
SVENSKA
© HAAG‑STREIT AG, 3098 Koeniz, Switzerland − HS‑Doc. no. 1500.7006000.04240 – 24. Edition / 2018 – 04
1.6.3 Service life of reusable measuring prisms
WARNING! How long can measuring prisms be used?
Due to the large number of variables to be considered (type and con‑ centration of the disinfectant used, number of patients, handling, etc.) it is practically impossible to provide exact information on how often and/ or how long a measuring prism can be used under safe conditions. The measuring prisms are stamped with an expiry date ( ). They must not be used beyond this date. HAAG‑STREIT recommends a maximum ser‑ vice life of two years before the expiry date. This service life applies sub‑ ject to normal conditions of use, i.e., in compliance with the instructions
contained in these instructions for use. The service life starts with the rst
use. The above‑mentioned time periods do not apply to damaged mea‑ suring prisms; these must be immediately replaced.
Service life:
Maximum two years
Service life:
Maximum two years
First use
First use
Replace
Replace
Year:
1.6.4 Tonosafe
NOTE!
Tonosafe was developed to avoid the necessary cleaning and disinfection of measuring prisms from applanation tonometers. Tonosafe is a dispos‑ able applanation and optical duplication prism for Goldmann and Perkins applanation tonometers, for single use. Additional details can be found in the separate instructions for use.
1.6.5 Monthly device checks
The tonometer must be checked on a monthly basis as described in the 'Mainte‑ nance' chapter. A check will be absolutely necessary if external force is applied (e.g., striking or dropping the appliance).
NOTE!
If a repair is necessary, please contact your HAAG‑STREIT representative.
1.7 Warranty and product liability
Haag-Streit products must be used only for the purposes and in the manner des-
cribed in the documents distributed with the product. The product must be treated as described in the ‘Safety’ chapter. Improper hand­ling can damage the product. This would void all guarantee claims. Continued use of a product damaged by incorrect handling may lead to personal injury. In such a case, the manufacturer will not accept any liability. Haag-Streit does not grant any warranties, either expressed or implied, including implied warranties of merchantability or fitness for a particular use. Haag-Streit expressly disclaims liability for incidental or consequential damage resulting from the use of the product. This product is covered by a limited warranty granted by your seller.
This product is covered by a limited warranty, which may be reviewed at www.haag-streit-usa.com.
For US
A only:
1.9 Description of symbols
European certificate of
conformity
General warning: Read the ac-
companying documentation
Date of manufacture
Manufacturer
HS reference number
Serial number
Expiry date
(YYYY-MM-DD)
LOT number
2. Introduction
The applanation tonometer functions according to the Goldmann method: measure‑ ment of the pressure required to maintain a uniform applanation of the surface of the cornea. The exact measurement of the applanation surface is performed at 10x
magnication on the slit lamp.
01-IFU_AT900-7006000-04240_eng.indd 6 03.05.2018 10:11:12