GW-INSTEK PSW-800-4-32 User guide

Multi-Range DC Power Supply
PSW Series
USER MANUAL
ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will company.
The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the rights to change specification, equipment, and maintenance procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
Table of Contents
Table of Contents
SAFETY INSTRUCTIONS .................................................. 5
GETTING STARTED .......................................................... 9
PSW Series Overview ................................................. 10
Appearance ................................................................ 16
Theory of Operation ................................................... 23
OPERATION .................................................................. 43
Set Up ....................................................................... 45
Basic Operation ......................................................... 63
Parallel / Series Operation ......................................... 77
Test Scripts ................................................................ 91
CONFIGURATION ......................................................... 102
Configuration ............................................................103
ANALOG CONTROL ...................................................... 123
Analog Remote Control Overview..............................124
Remote Monitoring ...................................................140
COMMUNICATION INTERFACE .................................... 145
Interface Configuration .............................................146
MAINTENANCE ............................................................ 161
FAQ .............................................................................. 163
APPENDIX .................................................................... 165
PSW Default Settings ................................................165
Error Messages & Messages .....................................168
3
PSW Series User Manual
LED Display Format ................................................. 168
PSW Specifications .................................................. 169
PSW Dimensions ..................................................... 184
Declaration of Conformity ........................................ 189
INDEX .......................................................................... 190
4
SAFETY INSTRUCTIONS
WARNING
Warning: Identifies conditions or practices that could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that could result in damage to the PSW or to other properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
SAFETY INSTRUCTIONS
This chapter contains important safety instructions that you must follow during operation and storage. Read the following before any operation to insure your safety and to keep the instrument in the best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the instrument.
5
PSW Series User Manual
Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased.
General Guideline
CAUTION
Do not place any heavy object on the PSW. Avoid severe impact or rough handling that
leads to damaging the PSW.
Do not discharge static electricity to the PSW. Use only mating connectors, not bare wires, for
the terminals.
Do not block the cooling fan opening. Do not disassemble the PSW unless you are
qualified.
(Measurement categories) EN 61010-1:2010 and EN 61010-2-030 specify the measurement categories and their requirements as follows. The PSW falls under category II.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
0 is for measurements performed on circuits not directly
connected to Mains.
Power Supply
WARNING
AC Input voltage range: 85VAC~265VAC Frequency: 47Hz~63Hz To avoid electrical shock connect the protective
grounding conductor of the AC power cord to an earth ground.
Safety Guidelines
6
SAFETY INSTRUCTIONS
Cleaning the PSW
Disconnect the power cord before cleaning. Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
Operation Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Relative Humidity: 20%~ 85% Altitude: < 2000m Temperature: 0°C to 50°C
(Pollution Degree) EN 61010-1:2010 and EN 61010-2-030 specify the pollution degrees and their requirements as follows. The PSW falls under degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to condensation which is expected. In such conditions, equipment is normally protected against exposure to direct sunlight, precipitation, and full wind pressure, but neither temperature nor humidity is controlled.
Storage environment
Location: Indoor Temperature: -25°C to 70°C Relative Humidity: <90%, no condensation
Disposal
Do not dispose this instrument as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Please make sure discarded electrical waste is properly recycled to reduce environmental impact.
7
PSW Series User Manual
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
Power cord for the United Kingdom
When using the power supply in the United Kingdom, make sure the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code:
As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact the supplier.
This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of 0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used.
Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous wiring must be immediately destroyed and replaced in accordance to the above standard.
8
GETTING STARTED
PSW Series Overview ................................................. 10
Series lineup ............................................................................................. 10
Main Features .......................................................................................... 11
Accessories .............................................................................................. 12
PSW 30/80/160 Accessories...................................................... 12
PSW 250/800 Accessories .......................................................... 13
Appearance ................................................................ 16
PSW Front Panel .................................................................................... 16
Rear Panel ................................................................................................ 19
Theory of Operation ................................................... 23
Operating Area Description ................................................................. 23
CC and CV Mode ................................................................................... 26
Slew Rate .................................................................................................. 28
Bleeder Control ....................................................................................... 28
Sink Current Table ................................................................................. 30
Internal Resistance ................................................................................. 36
Alarms ...................................................................................................... 36
Considerations ........................................................................................ 38
Grounding ............................................................................................... 41
GETTING STARTED
This chapter describes the power supply in a nutshell, including its main features and front / rear panel introduction. After going through the overview, please read the theory of operation to become familiar with the operating modes, protection modes and other safety considerations.
9
PSW Series User Manual
Note
Throughout the user manual, PSW 30, PSW 80, PSW 160, PSW 250 or PSW 800 will refer to any of the PSW models with a maximum voltage rating of 30V, 80V, 160V, 250V or 800V, respectively.
Model name
Type
Voltage Rating
Current Rating
Power
PSW 30-36
Type I
0~30V
0~36A
360W
PSW 80-13.5
Type I
0~80V
0~13.5A
360W
PSW 160-7.2
Type I
0~160V
0~7.2A
360W
PSW 250-4.5
Type I
0~250V
0~4.5A
360W
PSW 800-1.44
Type I
0~800V
0~1.44A
360W
PSW 30-72
Type II
0~30V
0~72A
720W
PSW 80-27
Type II
0~80V
0~27A
720W
PSW 160-14.4
Type II
0~160V
0~14.4A
720W
PSW 250-9
Type II
0~250V
0~9A
720W
PSW 800-2.88
Type II
0~800V
0~2.88A
720W
PSW 30-108
Type III
0~30V
0~108A
1080W
PSW 80-40.5
Type III
0~80V
0~40.5A
1080W
PSW 160-21.6
Type III
0~160V
0~21.6A
1080W
PSW 250-13.5
Type III
0~250V
0~13.5A
1080W
PSW 800-4.32
Type III
0~800V
0~4.32A
1080W
PSW Series Overview
Series lineup
The PSW series consists of 15 models, divided into 3 different model types covering 3 power capacities: Type I (360 Watt), Type II (720 Watt) and Type III (1080 Watt).
10
GETTING STARTED
360 Watt models
Type I
A
W
V
W
%W10080604020
ISR
C C
DLY
ALM
RMT
C V
VSR
Function OVP/OCP Set
Output
PWR DSPLLock/LocalTest
PS W 3 0 - 3 6
360W
Multi-Range DC Power Supply
Voltage
Current
720 Watt models
Type II
A
W
V
W
%W10080604020
ISR
C C
DLY
ALM
RMT
C V
VSR
Function OVP/OCP Set
Output
PWR DSPLLock/LocalTest
PS W 3 0 - 7 2
720W
Voltage
Current
Multi-Range DC Power Supply
1080 Watt models
Type III
A
W
V
W
%W10080604020
ISR
C C
DLY
ALM
RMT
C V
VSR
Function OVP/OCP Set
Output
PWR DSPLLock/LocalTest
PS W 3 0 - 1 0 8
1080W
Voltage
Current
Multi-Range DC Power Supply
Performance
High performance/power Power efficient switching type power supply Low impact on load devices Fast transient recovery time of 1ms Fast output response time
Features
OVP, OCP and OHP (OTP) protection Adjustable voltage and current slew rates User adjustable bleeder control to quickly
dissipate the power after shutdown to safe levels.
Extensive remote monitoring and control
options
Support for serial* and parallel connections.
*(30, 80, 160 volt models only)
Power on configuration settings. Supports test scripts Web server monitoring and control
Apart from the differences in output, each unit differs in size. The 720 and 1080 watt models are larger than the 360 watt models to accommodate the increase in power.
Main Features
11
PSW Series User Manual
Interface
Ethernet port Analog connector for analog voltage and current
monitoring
USB host and device port
Standard Accessories
Part number
Description
CD-ROM
User manual, programming manual
4323-30600101
Power cord (Type I/II)
4320-91001101
Power cord (Type III)
PSW-009
Output terminal cover
GTL-123
Test leads: 1x red, 1x black
GTL-240
USB Cable
PSW-004
Basic Accessory Kit:
M4 terminal screws and washers x2, M8 terminal bolts, nuts and washers x2, Air filter x1, Analog control protection dummy x1, Analog control lock level x1
Optional Accessories
Part number
Description GET-001
Extended terminal
GET-005
Extended terminal (Euro Type)
Accessories
Please check the contents before using the PSW.
PSW 30/80/160 Accessories
12
GETTING STARTED
PSW-001
Accessory Kit:
Pin contact x10, Socket x1, Protection cover x1
PSW-002
Simple IDC Tool
PSW-003
Contact Removal Tool
PSW-005
Series operation cable for 2 units.
PSW-006
Parallel operation cable for 2 units.
PSW-007
Parallel operation cable for 3 units.
GRA-410-J
Rack mount adapter (JIS)
GRA-410-E
Rack mount adapter (EIA)
GUG-001
GPIB to USB adapter
GTL-240
USB Cable
PSW-010
Large filter (Type II/III)
GUR-001A
RS-232 to USB adapter (Support only when firmware version is 2.25 or above)
Download
Name
Description
psw_cdc.inf
USB driver
Standard Accessories
Part number
Description
CD-ROM
User manual, programming manual
4323-30600101
Power cord (Type I/II)
PSW 250/800 Accessories
13
PSW Series User Manual
4320-91001101
Power cord (Type III)
PSW-011
High voltage output terminal cover
GTL-240
USB Cable
PSW-012
High voltage output terminal
PSW-008
Basic Accessory Kit:
(Air filter x1, Analog control protection dummy x1, Analog control lock level x1
Optional Accessories
Part number
Description GET-002
Extended terminal
PSW-001
Accessory Kit:
Pin contact x10, Socket x1, Protection cover x1
PSW-002
Simple IDC Tool
PSW-003
Contact Removal Tool
PSW-006
Parallel operation cable for 2 units.
PSW-007
Parallel operation cable for 3 units.
GRA-410-J
Rack mount adapter (JIS)
GRA-410-E
Rack mount adapter (EIA)
GTL-130
Test leads: 2x red, 2x black
GUG-001
GPIB to USB adapter
GTL-240
USB Cable
PSW-010
Large filter (Type II/III)
14
GETTING STARTED
GUR-001A
RS-232 to USB adapter (Support only when firmware version is 2.25 or above)
Download
Name
Description
psw_cdc.inf
USB driver
15
PSW Series User Manual
A
W
V
W
%W10080604020
ISR
C C
DLY
ALM
RMT
C V
VSR
Function OVP/OCP Set
Output
PWR DSPLLock/LocalTest
P S W 3 0 - 7 2
720W
Voltage
Current
Multi-Range DC Power Supply
Current knob
Output key
Power switch
Voltage knob
USB A port
Display
Cover panel
Function keys
1080W: PSW 30-108, 80-40.5, 160-21.6, 250-13.5, 800-4.32
360W: PSW 30-36, 80-13.5, 160-7.2, 250-4.5, 800-1.44
A
W
V
W
%W10080604020
ISR
C C
DLY
ALM
RMT
C V
VSR
Function OVP/OCP Set
Output
PWR DSPLLock/LocalTest
PS W 3 0 - 1 0 8
1080W
Voltage
Current
Multi-Range DC Power Supply
A
W
V
W
%W10080604020
ISR
C C
DLY
ALM
RMT
C V
VSR
Function OVP/OCP Set
Output
PWR DSPLLock/LocalTest
PS W 3 0 - 3 6
360W
Multi-Range DC Power Supply
Voltage
Current
Appearance
PSW Front Panel
720W: PSW 30-72, 80-27, 160-14.4, 250-9, 800-2.88
16
GETTING STARTED
Function Keys
The Function keys along with the Output key will light up when a key is active.
Function
The Function key is used to configure the power supply.
OVP/OCP
Set the over current or over voltage protection levels.
Set
Sets the current and voltage limits.
Test
Used to run customized scripts for testing.
Lock/Local
Locks or unlocks the panel keys to prevent accidentally changing panel settings.
PWR DSPL
Toggles the display from viewing V/A V/W or A/W*. *Press the Voltage knob for V/W, press the Current knob for A/W.
Display Indicators
VSR
Voltage Slew Rate
C V
Constant Voltage Mode
RMT
Remote Control Mode
ALM
Alarm on
DLY
Delay Output
C C
Constant Current Mode
ISR
Current Slew Rate
17
PSW Series User Manual
20 40 60 80 100 % W
Power bar Indicates the current power output
as a percentage.
Voltage Knob
Voltage
Sets the voltage.
Current Knob
Current
Sets the current.
Output
Output
Press to turn on the output. The Output key will light up when the output is active.
USB
USB A port for data transfer, loading test scripts etc.
Power Switch
Used to turn the power on/off.
18
GETTING STARTED
Output terminal (+)
Fan
Output terminal (-)
USB B port
LAN
AC Input
Sense­terminal
Analog control connector
LAN
100 240V
1000VA MAX.
AC 47 63Hz
SER.NO. LABEL
Sense+ terminal
Chassis ground
1080W: PSW 30-108, 80-40.5, 160-21.6
360W: PSW 30-36, 80-13.5, 160-7.2
100 240VAC
1500VA MAX.
47 63Hz
LAN
LN
SER.NO. LABEL
AC Input
LAN
100 240V
47 63Hz 500VA MAX.
AC
Rear Panel
720W: PSW 30-72, 80-27, 160-14.4
19
PSW Series User Manual
LAN
100 240V
1000VA MAX.
AC 47 63Hz
SER.NO. LABEL
V SN.C. S V
Output terminals +V
Fan
Chassis ground
USB B port
LAN
AC Input
Sense­terminal
Analog control connector
Sense+ terminal
Output terminals -V
1080W: PSW 250-13.5, 800-4.32
360W: PSW 250-4.5, 800-1.44
LAN
LN
SER.NO. LABEL
47 63Hz
1500VA MAX.
AC100 240V
V VSN.C. S
AC Input
LAN
100 240V
47 63Hz500VA MAX.
AC
V SN.C. S V
720W: PSW 250-9, 800-2.88
20
GETTING STARTED
Analog Control Connector
Standard 26 pin MIL connector (OMRON XG4 IDC plug).
The analog control connector is used to monitor current and voltage output, machine status (OVP, OCP, OHP (OTP) etc.), and for analog control of the current and voltage output.
Use an OMRON XG5 IDC socket as the mating socket.
Output Terminals (30, 80, 160 volt models)
Positive (+) and negative (-) output terminals.
Chassis ground
Sense (-S) and Sense (+S) terminals.
Output Terminals (250, 800 volt models)
The 250 and 800 volt models use a 9 pin connector and a plug for the output and sense terminal connections. The plug is a MC420-38109Z plug by DECA SwitchLab Inc. This plug is also available separately (GW part number PSW-012).
V SN.C. S V
Positive (V+) and negative (V-) output terminals (3 of each).
V SN.C. S V
Chassis ground
21
PSW Series User Manual
V SN.C. S V
Sense (-S) and Sense (+S) terminals.
USB B port
The USB B port is used for remote control.
Fans
Temperature controlled fans
Ethernet Port
LAN
The ethernet port is used for remote control and digital monitoring from a PC.
Line Voltage Input
(Type I/TypeII)
Type I: PSW 30-36/80-13.5/ 160-7.2/250-4.5, 800-1.44
Type II: PSW 30-72/80-27/ 160-14.4/250-9, 800-2.88
Voltage Input: 100~240 VAC Line frequency: 50Hz/60 Hz
(Automatically switchable)
Line Voltage Input
(Type III)
LN
Type III: PSW 30-108/80-40.5/160-21.6/ 250-13.5/800-4.32
Voltage Input: 100~240 VAC Line frequency: 50Hz/60 Hz
(Automatically switchable)
22
GETTING STARTED
Background
The PSW power supplies are regulated DC power supplies with a high voltage and current output. These operate in CC or CV mode within a wide operating range limited only by the output power.
The operating area of each power supply is determined by the rated output power as well as the voltage and current rating. For example the operating area and rated power output for the PSW 30-36 is shown below.
Voltage
Current
30
360W rated power
10
12 36
PSW 30-36 Operating Area
When the power supply is configured so that the total output (current x voltage output) is less than the rated power output, the power supply functions as a typical constant current, constant voltage power supply.
If however, the power supply is configured such that the total output (current x voltage output) exceeds the rated power output, the
Theory of Operation
The theory of operation chapter describes the basic principles of operation, protection modes and important considerations that must be taken into account before use.
Operating Area Description
23
PSW Series User Manual
effective output is actually limited to the power limit of the unit. In this case the output current and voltage then depend purely on the load value.
Below is a comparison of the operating areas of each power supply.
PSW 800V Series Operating Area
0
100
800
Current (A)
Voltage (V)
200
300
400
700
0
1
2
3
4
900
5
Type III
Type II
Type I
500
600
0.45 0.9 1.35
800
250
2.88 4.321.44
PSW 250V Series Operating Area
Current (A)
Voltage (V)
0
3
6
9
12
15
Type III
Type II
Type I
1.44 2.88 4.32
250
80
9 13.54.5
250
200
150
100
50
0
24
GETTING STARTED
PSW 160V Series Operating Area
0
20
160
Current (A)
Voltage (V)
40
60
80
140
0
5
10
15
20
180
25
Type III
Type II
Type I
100
120
2.25 4.5 6.75
160
50
14.4 21.67.2
PSW 80V Series Operating Area
Current (A)
Voltage (V)
26.6
4.5 9.0 13.5
80
Type III
Type II
Type I
30
45
40205
10
15
25
0
35
0
20
40
60
80
90
27 40.5
25
PSW Series User Manual
PSW 30V Series Operating Area
0
5
30
Current (A)
Voltage (V)
10
15
20
25
0 20
40
60
80
100
10
12 24 36
30
35
120
Type III
Type II
Type I
72 108
CC and CV mode Description
When the power supply is operating in constant current mode (CC) a constant current will be supplied to the load. When in constant current mode the voltage output can vary, whilst the current remains constant. When the load resistance increases to the point where the current limit (I
SET
) can no longer be sustained the power supply switches to CV mode. The point where the power supply switches modes is the crossover point.
When the power supply is operating in CV mode, a constant voltage will be supplied to the load, whilst the current will vary as the load varies. At the point that the load resistance is too low to maintain a constant voltage, the power supply will switch to CC mode and maintain the set current limit.
The conditions that determine whether the power supply operates in CC or CV mode depends on the set current (I
SET
), the set voltage
CC and CV Mode
26
GETTING STARTED
(V
SET
), the load resistance (RL) and the critical resistance (RC). The critical resistance is determined by V
SET/ISET
. The power supply will operate in CV mode when the load resistance is greater than the critical resistance. This means that the voltage output will be equal to the V
SET
voltage but the current will be
less than I
SET
. If the load resistance is reduced to the point that the current output reaches the I
SET
level, the power supply switches to CC
mode.
Conversely the power supply will operate in CC mode when the load resistance is less than the critical resistance. In CC mode the current output is equal to I
SET
and the voltage output is
less than V
SET
.
RL=R
C
RL<R
C
VSET
ISET
CV
CC
V
I
RL>R
C
Crossover
point
27
Slew Rate
Theory
The PSW has selectable slew rates for CC and CV mode. This gives the PSW power supply the ability to limit the current/voltage draw of the power supply. Slew rate settings are divided into High Speed Priority and Slew Rate Priority. High Speed Priority mode disables slew rate settings for CC or CV mode. Slew Rate Priority mode allows for user adjustable slew rates for CC or CV mode. The rising and falling slew rate can be set independently.
Slew rate=
Disabled
Slew rate =
Enabled
Background
The PSW DC power supplies employ a bleed resistor in parallel with the output terminals.
PSW
Load
Bleed
resistor
Bleed resistors are designed to dissipate the power from the power supply filter capacitors
PSW Series User Manual
Bleeder Control
28
GETTING STARTED
when power is turned off and the load is disconnected. Without a bleed resistor, power may remain charged on the filter capacitors for some time and be potentially hazardous.
In addition, bleed resistors also allow for smoother voltage regulation of the power supply as the bleed resistor acts as a minimum voltage load.
The bleed resistance can be turned on or off using the configuration settings.
Note
By default the bleed resistance is on. For battery charging applications, be sure to turn the bleed resistance off as the bleed resistor can discharge the connected battery when the unit is off.
29
PSW Series User Manual
Background
Sink current (reference value) from an external voltage source according to the bleeder circuit setting.
PSW 30-36
Vout
Bleeder ON
Bleeder OFF
Sink Current
(V)
(A)
(mA)
1
1.455
0.000
3
1.733
0.000 5 1.559
0.002
10
1.123
0.009
15
0.715
0.014
20
0.471
0.021
25
0.353
0.031
30
0.267
0.038
PSW 30-72
Vout
Bleeder ON
Bleeder OFF
Sink Current
(V)
(A)
(mA) 1 2.378
0.000
3
3.613
0.000 5 3.249
0.004
10
2.340
0.008
15
1.487
0.014
20
0.974
0.022
25
0.730
0.028
30
0.544
0.048
Sink Current Table
30
Loading...