GW Instek PSU Series, PSU 40-38, PSU 60-25, PSU 6-200, PSU 12.5-120 Quick Start Manual

...
Programmable DC Power Supply
PSU Series
QUICK START GUIDE
GW INSTEK PART NO. 82SU-60250MD1
ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will company.
The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the rights to change specification, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
Table of Contents
1
Table of Contents
SAFETY INSTRUCTIONS ................................................... 2
GETTING STARTED ........................................................... 6
PSU Series Overview .............................. 6
Appearance .......................................... 11
OPERATION .................................................................... 19
Set Up .................................................. 19
Basic Operation ................................... 22
APPENDIX ...................................................................... 31
PSU Dimensions .................................. 31
Declaration of Conformity .................... 32
PSU Series Quick Start Guide
2
SAFETY INSTRUCTIONS
This chapter contains important safety instructions that you must follow during operation and storage. Read the following before any operation to insure your safety and to keep the instrument in the best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the instrument.
WARNING
Warning: Identifies conditions or practices that could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that could result in damage to the PSU or to other properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
SAFETY INSTRUCTIONS
3
Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased.
Safety Guidelines
General Guideline
CAUTION
Do not place any heavy object on the PSU. Avoid severe impact or rough handling that
leads to damaging the PSU.
Do not discharge static electricity to the PSU. Use only mating connectors, not bare wires, for
the terminals.
Do not block the cooling fan opening. Do not disassemble the PSU unless you are
qualified.
(Measurement categories) EN61010-1:2010 and EN61010-2-030 specifies the measurement categories and their requirements as follows. The PSU falls under category II.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
0 is for measurements performed on circuits not directly
connected to Mains.
Power Supply
WARNING
AC Input voltage range: 85Vac~265Vac Frequency: 47Hz to 63Hz To avoid electrical shock connect the protective
grounding conductor of the AC power cord to an earth ground.
PSU Series Quick Start Guide
4
Cleaning the PSU
Disconnect the power cord before cleaning. Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
Operation Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Relative Humidity: 20%~ 85% (no condensation) Altitude: < 2000m Temperature: 0°C to 50°C
(Pollution Degree) EN61010-1:2010 and EN61010-2-030 specifies the pollution degrees and their requirements as follows. The PSU falls under degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to condensation which is expected. In such conditions, equipment is normally protected against exposure to direct sunlight, precipitation, and full wind pressure, but neither temperature nor humidity is controlled.
Storage environment
Location: Indoor Temperature: -25°C to 70°C Relative Humidity: 90%(no condensation)
Disposal
Do not dispose this instrument as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Please make sure discarded electrical waste is properly recycled to reduce environmental impact.
SAFETY INSTRUCTIONS
5
Power cord for the United Kingdom
When using the power supply in the United Kingdom, make sure the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code:
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact the supplier.
This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of 0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used.
Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous wiring must be immediately destroyed and replaced in accordance to the above standard.
PSU Series Quick Start Guide
6
GETTING STARTED
This chapter describes the power supply in a nutshell, including its main features and front / rear panel introduction. After going through the overview, please read the theory of operation to become familiar with the operating modes, protection modes and other safety considerations.
PSU Series Overview
Series lineup
The PSU series consists of 5 models, covering a number of different current, voltage and power capacities:
Model name
Voltage Rating1
Current Rating2
Power
PSU 6-200
6V
200A
1200W
PSU 12.5-120
12.5V
120A
1500W
PSU 20-76
20V
76A
1520W
PSU 40-38
40V
38A
1520W
PSU 60-25
60V
25A
1500W
1
Minimum voltage guaranteed to 0.2% of rating voltage.
2
Minimum current guaranteed to 0.4% of rating current.
GETTING STARTED
7
Main Features
Performance
High power density: 1500W in 1U Universal input voltage 85~265Vac, continuous
operation.
Output voltage up to 60V, current up to 200A.
Features
Active power factor correction. Parallel master/slave operation with active
current sharing.
Remote sensing to compensate for voltage drop
in load leads.
19" rack mounted ATE applications. A built-in Web server that lets you monitor the
instrument directly from an internet browser on your computer.
OVP, OCP and OHP protection. Preset memory function. Adjustable voltage and current slew rates. Bleeder circuit ON/OFF setting. (to prevent
over-discharging of batteries)
CV, CC priority start function. (prevents
overshoot with output ON)
Supports test scripts.
Interface
Built-in RS-232/485, LAN and USB interface. Analog output programming and monitoring. Optional interfaces: GPIB, Isolated Voltage (0-
5V/0-10V) and Isolated Current (4-20mA) programming and monitoring interface. (Factory options)
PSU Series Quick Start Guide
8
Accessories
Before using the PSU power supply unit, check the package contents to make sure all the standard accessories are included.
Standard Accessories
Part number
Description
Qty. Output terminal cover
1
Analog connector plug kit
1
Output terminal M8 bolt set
1
Input terminal cover
1 62SB-8K0HD101
1U Handle, ROHS
2
62SB-8K0HP101
1U BRACKET (LEFT), RoHS
1
62SB-8K0HP201
1U BRACKET (RIGHT), RoHS
1
CD-ROM
User manual, Programming Manual
1 set Quick start guide
1
82SU-062H0K01
Packing list
82GW-00000C01
* CTC GW/INSTEK JAPAN USE ,RoHS
1
Factory Installed Options
Part number
Description PSU-GPIB
GPIB interface
PSU-ISO-V
Voltage programming isolated analog interface
PSU-ISO-I
Current programming isolated analog interface
GETTING STARTED
9
Optional Accessories
Part number
Description
PSU-01C
Cable for 2 units of PSU-Series in parallel mode connection
PSU-01B
Bus Bar for 2 units of PSU-Series in parallel mode connection
PSU-01A
Joins a vertical stack of 2 PSU units together. 2U-sized handles x2, joining plates x2.
PSU-02C
Cable for 3 units of PSU-Series in parallel mode connection
PSU-02B
Bus Bar for 3 units of PSU-Series in parallel mode connection
PSU-02A
Joins a vertical stack of 3 PSU units together. 3U-sized handles x2, joining plates x2.
PSU-03C
Cable for 4 units of PSU-Series in parallel mode connection
PSU-03B
Bus Bar for 4 units of PSU-Series in parallel mode connection
PSU-03A
Joins a vertical stack of 4 PSU units together. 4U-sized handles x2, joining plates x2.
PSU-232
RS232 cable with DB9 connector kit
PSU-485
RS485 cable with DB9 connector kit
GRM-001
Rack-mount slides (General Devices P/N: C-300-S-116-RH-LH)
GTL-246
USB Cable 2.0-A-B Type, Approx. 1.2M
GPW-001
Power Cord SJT 12AWG/3C, 3m MAX Length, 105 ºC, RNB5-5*3P UL/CSA type
GPW-002
Power Cord H05W-F 1.5mm2/3C, 3m MAX Length, 105 ºC, RNB5-5*3P VDE type