GSi PNEG-1016, APP Series, APPB-36, APPB-36C, APPB-50 Assembly And Operation Manual

...
PNEG-1016
APP Series Knockdown Fan
Installation, Assembly and Operation Manual
PNEG-1016
Date: 05-29-13
Read carefully before attempting to assemble, install, operate or maintain the product d escribed. Prote ct yourself and others by observing all safety information. Use only genuine AP parts in the installation of fans, use of non-genuine parts or failure to comply with instructions could result in persona l injury a nd/or property damage. This fan is not designed for use in atmospheres where risk of explosion is foreseen. Such environments may include enclosed areas of high dust concentrations, gas vapors and fumes. Use in such an atmosphere is prohibited. If in doubt, contact AP or your dealer.
Retain instructions for future reference.
Fan Models CFM at 0.00 SP Weight Lbs./kgs Cubic Ft./mtrs
APPB-36* 11113 135 Lbs./61.20 kgs 34.5 Ft./0.97 mtrs
APPB-36C* 12290 170 Lbs./77.10 kgs 55.7 Ft./1.58 mtrs
APPB-50* 20856 214 Lbs./97.00 kgs 65 Ft./1.85 mtrs
APPB-50C* 23894 265 Lbs./120.20 kgs 65 Ft./1.85 mtrs
* Add - BLK suffix to end of fan model number for black fans.
For guidance or assistance on any issues relating to the safe use of your APP Fan contact AP. Our address is:
Automated Production
1004 E. Illinois St. Assumption, IL. 62510 Phone: 1-217-226-4421
2 PNEG-1016 APP Series Knockdown Fan
Table of Contents
Contents
Chapter 1 Safety .................................. ................... ................... .................... ................... ......................................4
Safety Guidelines ... ... ... ... .......................................................................................................................4
Safety Instructions ..................... ... .... .......................................... ... ... ... ... .... ............................................5
General Safety Information ....................................................................................................................6
Chapter 2 Decals .................................... .................................................... ............................................................7
Safety Signs and Warnings ....................................................................................................................7
Chapter 3 Installation ............................................................................................................................................9
Chapter 4 Operation ............................................................................................................................................10
Chapter 5 Maintenance ....................................... ................... .................... ................... .......................................11
Cleaning ...............................................................................................................................................11
Lubrication .............................. ............. ............. ............. ............. ............ ............. .................................11
Chapter 6 Wiring ..................................................................................................................................................12
Electrical Wiring ...................................................................................................................................12
Belt Drive Wirings for Single Phase Motors .........................................................................................13
Chapter 7 Dimension Chart .................................................................................................................................14
Chapter 8 AP Belt Drive Fan Assembly Instructions ................................. .......................... ......................... ....15
Assembling the Motor Mount Leg and Bearing Plate ...........................................................................15
Installing the Motor and Bearing Support Assembly into the Fan Housing ..........................................16
Assembling the Motor ..........................................................................................................................18
Installing the Motor ...............................................................................................................................20
Aligning the Tensioner Arm ..................................................................................................................21
Installing the Bearings ............................... ... .... ... ... ... .......................................... .... ... ... ... ....................21
Installing the Driven Pulley onto the Shaft ...........................................................................................23
Installing the Propellar ..........................................................................................................................24
Installing the Belt .............................. ... ... .......................................... ... .................................................25
Chapter 9 Installing a Discharge Cone ..............................................................................................................26
Assembling a Segmented Discharge Cone .........................................................................................27
Mounting the Cone to the Fan Housing ...............................................................................................28
Guard Detail for 50" Fan ......................................................................................................................29
Chapter 10 Parts List ...........................................................................................................................................30
Chapter 11 Warranty ........................................... ................................................ .................................................31
PNEG-1016 APP Series Knockdown Fan 3
1. Safety
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to personal injury.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Safety Guidelines
This manual contains information that is important for you, the owner/operator, to know and understand. This information relates to protecting personal safety and preventing equipment problems. It is the responsibility of the owner/operator to inform anyone operating or working in the area of this equipment of these safety guidelines. To help you recognize this information, we use the symbols that are defined below. Please read the manual and pay attention to these sections. Failure to read this manual and its safety instructions is a misuse of the equipment and may lead to serious injury or death.
DANGER
WARNING
CAUTION
NOTICE
4 PNEG-1016 APP Series Knockdown Fan
1. Safety
Follow Safety Instructions
Carefully read all safety messages in this manual and safety signs on your machine. Keep signs in good condition. Replace missing or damaged safety signs. Be sure new equipment components and repair parts include the current safety signs. Replacement safety signs are available from the manufacturer.
Learn how to operate the machine and how to use controls properly. Do not let anyone operate without instruction.
Keep your machinery in proper working condition. Unauthorized modifications to the machine may impair the function and/or safety and affect machine life.
If you do not understand any part of this manual or need assistance, contact your dealer.
Read and Understand Manual
Safety Instructions
Our foremost concern is your safety and the safety of others associated with this equipment. We want to keep you as a customer. This manual is to help you understand safe operating procedures and some problems that may be encountered by the operator and other personnel.
As owner and/or operator, it is your responsibility to know what requirements, hazards, and precautions exist, and to inform all personnel associated with the equipment or in the area. Safety precautions may be required from the personnel. Avoid any alterations to the equipment. Such alterations may produce a very dangerous situation where SERIOUS INJURY or DEATH may occur.
This equipment shall be installed in accordance with the current installation codes and applicable regulations, which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.
User Manual
This manual contains information and instructions essential to the safe installation and use of the APP Series Knockdown Fans. Read this manual thoroughly before attempting any installation or use of the APP Fan. Keep this manual with the APP Fan or in a location where it can be readily accessed. Failure
to read this manual and its safety instructions is a misuse of the equipment.
Correct Use of the APP Series Knockdown Fan
The APP Series Knockdown Fan is designed solely for the purpose of ventilating agricultural buildings. Use of the system in any other way is a misuse of the system and may endanger safety and health.
Only genuine AP parts are to be used in the installation and use of the APP Series Knockdown Fan. Use of other non-genuine parts is a misuse of the system and may lead to dangerous situations imperilling the safety and health of you and others.
This machine is not designed for use in atmospheres where there is a risk of explosion. Such environments may include enclosed areas of high dusts concentrations, gas vapors and fumes. Use of the APP Fan in such an environment is prohibited. If in doubt, contact AP or your dealer.
PNEG-1016 APP Series Knockdown Fan 5
1. Safety
Unpacking
When receiving the unit, inspect carefully for any damage that may have occurred during transit. Shipping damage claim must be filed with carrier.
Electrical Safety
An adequate and safe power supply to the APP Series Knockdown Fan unit is essential for safety. A competent and qualified electrician must undertake all electrical wiring. All wiring is to be installed according to the National Standards and Regulations relevant to your Country and Region.
Safety Guards
The APP Series Knockdown Fan contains many moving and electrical parts, which will cause serious injury or death if touched. Guards are placed on the machine for your protection. Operating the machine at any time with guards removed or incorrectly fitted is a serious misuse of the machine and endangers safety.
Safety in Handling the APP Series Knockdown Fan
Manual handling of the fans can be a cause of serious injury. Wherever possible, use mechanical lifting equipment when lifting or moving fans during installation. Where manual handling is required, seek assistance from other people.
To prevent injury, use suitable hand protection.
Safety in Maintenance
While the APP Series Knockdown Fan is designed to keep maintenance to a minimum, some repairs will be necessary in the course of the life of the machine. Do not attempt any repairs on the machine unless you are competent to do so. Remember that the APP Series Knockdown Fan may in cases operate under automatic control and start without warning. Never attempt any work on the APP Series Knockdown Fan without first isolating the machine from the main power and locking the isolator so that only you can turn the power back ON.
Follow all the guidelines given in the maintenance section on Page 11 of this manual. Before restarting the APP Series Knockdown Fan, ensure that all electrical enclosures are locked closed
and all guards and other safety measures are correctly fitted. If in any doubt, contact your dealer or AP for assistance.
General Safety Information
This unit should be assembled and installed by a qualified technician. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA). Motor must be securely and adequately grounded. This can be accomplished by wirin g with a grou nded,
metal-clad raceway system by using a separate ground wire connected to the motor’s ground lug or other suitable means.
Protect power cable from coming in contact with sharp objects. Do not kink power cable and never allow cable to come in contact with oil, grease, hot surfaces,
or chemicals. Make certain that the power source conforms to requirements of the equipment.
6 PNEG-1016 APP Series Knockdown Fan
2. Decals
Lockout power before servicing.
HIGH VOLTAGE
Will cause serious injury or death.
STAY CLEAR OF ROTATING BLADE
May cause serious injury.
Blade may start automatically.
Disconnect and lockout power sources before servicing.
FLYING OBJECTS HAZARD
Danger of eye injury.
Wear eye protection.
DANGERDANGER
WARNING
WARNING
DC-1540The GSI Group 217-226-4421
WARNING
DC-1018
Inside housing
DANGER
Lockout power before servicing.
HIGH VOLTAGE
Will cause serious injury or death.
STAY CLEAR OF ROTATING BLADE
May cause serious injury.
Blade may start automatically.
Disconnect and lockout power sources before servicing.
FLYING OBJECTS HAZARD
Danger of eye injury.
Wear eye protection.
DANGERDANGER
WARNING
WARNING
DC-1540The GSI Group 217-226-4421
Safety Signs and Warnings
The following pages show you exactly where the safety signs and warnings (d ecals) should be placed on your APP Series Knockdown Fan. If a decal is missing, damaged or unreadable, please contact your dealer or AP for a free replacement.
WARNING
SHEAR POINT
Keep hands clear of moving parts. Do not operate with guard removed. Disconnect and lockout power before servicing.
DC-995GSI Group Inc. 217-226-4421
DANGER
HIGH VOLTAGE
Will cause serious injury or death.
Lockout power before servicing.
PNEG-1016 APP Series Knockdown Fan 7
WARNING
STAY CLEAR OF ROTATING BLADE
Blade may start automatically.
May cause serious injury.
Disconnect and lockout power sources before servicing.
WARNING
FLYING OBJECTS HAZARD
Danger of eye injury.
Wear eye protection.
DC-1540The GSI Group 217-226-4421
2. Decals
Left side
DANGER
DANGER
Right side
Lockout power before servicing.
HIGH VOLTAGE
Will cause serious injury or death.
STAY CLEAR OF ROTATING BLADE
May cause serious injury.
Blade may start automatically.
Disconnect and lockout power sources before servicing.
FLYING OBJECTS HAZARD
Danger of eye injury.
Wear eye protection.
DANGERDANGER
WARNING
WARNING
DC-1540The GSI Group 217-226-4421
DANGER
Motor mount plate
DANGER
DANGER
DANGER
HIGH VOLTAGE
Will cause serious injury or death.
Lockout power before servicing.
WARNING
STAY CLEAR OF ROTATING BLADE
Blade may start automatically.
May cause serious injury.
Disconnect and lockout power sources before servicing.
WARNING
FLYING OBJECTS HAZARD
Danger of eye injury.
Wear eye protection.
DC-1540The GSI Group 217-226-4421
DANGER
HIGH VOLTAGE
Will cause serious injury or death. Lockout power before servicing.
WARNING
STAY CLEAR OF ROTATING BLADE
Blade may start automatically. May cause serious injury.
Disconnect and lockout power sources before servicing.
WARNING
FLYING OBJECTS HAZARD
Danger of eye injury.
Wear eye protection.
DC-1540The GSI Group 217-226-4421
DANGER
WARNING
STAY CLEAR OF ROTATING BLADE
Blade may start automatically. May cause serious injury.
Disconnect and lockout power sources before servicing.
WARNING
HIGH VOLTAGE
FLYING OBJECTS
Will cause serious
HAZARD
injury or death.
Danger of eye injury.
Lockout power before servicing.
Wear eye protection.
DC-1540The GSI Group 217-226-4421
DANGER
HIGH VOLTAGE
Will cause serious injury or death.
Lockout power before servicing.
8 PNEG-1016 APP Series Knockdown Fan
WARNING
STAY CLEAR OF ROTATING BLADE
Blade may start automatically.
May cause serious injury.
Disconnect and lockout power sources before servicing.
WARNING
FLYING OBJECTS HAZARD
Danger of eye injury.
Wear eye protection.
DC-1540The GSI Group 217-226-4421
DANGER
HIGH VOLTAGE
Will cause serious injury or death. Lockout power before servicing.
STAY CLEAR OF ROTATING BLADE
Blade may start automatically. May cause serious injury.
Disconnect and lockout power sources before servicing.
FLYING OBJECTS HAZARD
Danger of eye injury.
Wear eye protection.
WARNING
WARNING
DC-1540The GSI Group 217-226-4421
3. Installation
Fans should be installed in an exterior wall located where there will be no obstructions to the flow of air into or out of the fan.
Once a location has been determined, an opening should be made in the wall and framed to provide enough clearance around the fan housing. (See rough opening chart on Page 10.)
Framing must be able to support the weight of the fan assembly. Manual handling of the fans may result in serious injury. Where appropriate, use mechanical methods of
lifting during installation. Where manual handling is required, ensure you have adequate assistance. Position fan assembly in the framed opening. Rigidly mount the housing side flanges to the framework
using mounting screws. Remove electrical cover and connect power leads to motor terminals, using approved wiring method.
It is recommended to use the watertight connector included with the motor, if it is possible in the application. (Motor terminal connection data is provided on motor nameplate and in this manual.) Use adequate size wire for all branch and feeder runs. When speed control is used, follow the installation procedures recommended by the speed control manufacturer.
Re-install electrical cover. Unit is now ready for operation.
PNEG-1016 APP Series Knockdown Fan 9
4. Operation
* Add - BLK suffix to end of fan model for black fans.
Fan Model Width (in.) Inside Height (in.) Outside Height (in.)
B A
APPB-36* 44-1/2 44-1/2 43-1/2 APPB-50* 56 56 55
Figure 4A
Ref # Description
A Outside House Height B Inside House Height
Units may be operated using a switch, thermostat, timer or controller. Follow wiring and operation instructions furnished with the control system selected. When using speed controllers, follow the operation procedures recommended by the
controller manufacturer.
1. Set thermostat setting to a desired temperature. Fan will operate only when ambient temperature is above the thermostat set temperature.
2. Some controllers have idle speed controls. Set idle speed such that the blade RPM is within the RPM range listed in the performance table.
10 PNEG-1016 APP Series Knockdown Fan