Grasslin tasu 472 1 plus, tasu 472 plus, MIL 02T D220 Instruction Manual

GB
Instruction Manual tasu 472 (1) plus / MIL 02T D220
3
GB
page
Safety precautions, short description, wiring diagram.................................................................4
OK
reset
Menu
Prog
Prog.
Pre-set programs.............................................................................................................................................8
P0x
prog
Selecting pre-set programs P01 to P03
................................................................................................9
P--
prog
User defined programs ...............................................................................................................................10
del
+1h
Summer/winter time ....................................................................................................................................14
Automatic operation / fixed ON / fixed OFF .....................................................................................14
Safety precautions
· The connection and installation of electrical devices may only be carried out by a qualified electrician.
· Interventions in and changes to the device result in the voiding of the warranty claim.
· Observe your national regulations and the respective safety provisions.
· Switch-off commands have priority over switch-on commands.
Short description
This electronic time switch is designed to switch the double tariff relay of a meter by means of a switched neutral hardwired internally to the time switch motor neutral and an isolated switched output which can be utilized to switch a contactor to control e.g. storage heating.
The 2 switched outputs are interlocked to work in electric opposition i.e. when one contact is closed the other is open and vice versa.
To gain access to the setting control the terminal cover and clear perspex cover should be removed. Care should be execised in removing and replacing the perspex cover which when correctly positioned fits easily on the front of the time switch.
Wiring diagram
1 2 4 6 8
M
L N Sw
Neutral meter
NSH Contactor
Contact State, Switching Time & LCD Indication
Energised De-energised
0800 - 2300
7-Day
2300 - 0800
7-Day
Contacts revert to the de-energised position in the event of loss of supply to time switch
4
5
GB
5
Technical Data
Supply voltage see inprint on device Switching capacity see inprint on device Ambient temperature -25ºC to +55ºC Protection class IP 51 electronic IP 20 terminal box Accuracy +/- 1 sec day at 20ºC Reserve power 3 years from factory at +20ºC Shortest switching time 1 min Memory spaces 20
OK
reset
: Overview of daily switching
program
: Setting of 24h or am/pm
: Summer/winter clock changes
: Weekday display
: Switching status display ON/OFF
: Manual operation / fixed ON /
fixed OFF
: Automatic operation
+/- : Adjustment keys: By pressing the key longer than 2 sec. you can adjust the timer in steps of 5 units
Res. : Reset Menu : By pressing the menu key
programming is terminated and the system reverts to automatic operation OK : Confirmation of programming
1 2 3 4 5 6 7
14
16
18
20
22
24
+ - Menu OK
Res.
+1h