Grundig VERTIGA-UMS-4600-DEC Service Manual

HiFi Service Manual
VERTIGA UMS 4600 DEC
GLR1200
Zusätzlich erforderliche Unterlagen für den Komplettservice Additionally required Service Documents for the Complete Service
Service Manual
Sicherheit
Materialnr./Part No.
720108000001
Materialnummer/Part Number 720107740000 Änderungen vorbehalten/Subject to alteration TCC 0206 HH • Prepared in Germany http://www.grundig.com
NUR FÜR INTERNEN GEBRAUCH
FOR INTERNAL USE ONLY
GRUNDIG Service VERTIGA UMS 4600 DEC
Es gelten die Vorschriften und Sicherheitshin­weise gemäß dem Service Manual "Sicherheit", Materialnummer 720108000001, sowie zusätz­lich die eventuell abweichenden, landes­spezifischen Vorschriften!
Inhaltsverzeichnis
Seite
Allgemeiner Teil ............................... 1-2 … 1-12
Messgeräte / Messmittel .............................................................. 1-2
Allgemeine Hinweise .................................................................... 1-2
Technische Daten ........................................................................ 1-3
Servicehinweise ........................................................................... 1-3
Bedienhinweise ............................................................................ 1-4
Ausbauhinweise ......................................................................... 1-12
Abgleichvorschriften .................................... 2-1
Platinenabbildungen
und Schaltpläne ............................... 3-1 … 3-14
Blockschaltplan ............................................................................ 3-1
Verdrahtungsplan ......................................................................... 3-2
Netzteil ......................................................................................... 3-3
Verstärker .................................................................................... 3-4
Hauptplatte ................................................................................... 3-5
CD-Teil ......................................................................................... 3-8
USB-Teil ..................................................................................... 3-11
Display-Platte/Bedienteil ............................................................ 3-13
The regulations and safety instructions shall be valid as provided by the "Safety" Service Manual, part number 720108000001, as well as the re­spective national deviations!
Table of Contents
Page
General Section ................................ 1-2 … 1-12
Measuring Instruments / Equipment ............................................ 1-2
General Notes .............................................................................. 1-2
Technical Data ............................................................................. 1-3
Service Hints ................................................................................ 1-3
Operating Hints ............................................................................ 1-8
Disassembly Hints ..................................................................... 1-12
Adjustment Procedures................................ 2-1
Layout of PCBs
and Circuit Diagrams ....................... 3-1 … 3-14
Block Diagram .............................................................................. 3-1
Wiring Diagram ............................................................................ 3-2
Power Supply ............................................................................... 3-3
Amplifier ....................................................................................... 3-4
Main PCB ..................................................................................... 3-5
CD Section ................................................................................... 3-8
USB Section ............................................................................... 3-11
Display Board/Keyboard ............................................................ 3-13
Explosionszeichnung und
Ersatzteilliste ...................................... 4-1 … 4-2
Explosionszeichnung ................................................................... 4-1
Ersatzteilliste ................................................................................ 4-2
Allgemeiner Teil
Messgeräte / Messmittel
Mess-Sender Wobbelsender Oszilloskop Digitalvoltmeter Trenntrafo Klirrfaktormessgerät
Allgemeine Hinweise
Vor dem Öffnen des Gehäuses zuerst den Netzstecker ziehen! Achtung: ESD-Vorschriften beachten Leitungsverlegung
Bevor Sie die Leitungen und insbesondere die Masseleitungen lösen, muss die Leitungsverlegung zu den einzelnen Baugruppen beachtet werden. Nach erfolgter Reparatur ist es notwendig, die Leitungsführung wieder in den werkseitigen Zustand zu versetzen um evtl. spätere Ausfälle oder Störungen zu vermeiden.
Durchführen von Messungen
Bei Messungen mit dem Oszilloskop an Halbleitern sollten Sie nur Tastköpfe mit 10:1 - Teiler verwenden. Außerdem ist zu beachten, dass nach vorheriger Messung mit AC-Kopplung der Koppelkonden­sator des Oszilloskops aufgeladen sein kann. Durch die Entladung über das Messobjekt können Bauteile beschädigt werden.
Messwerte
Bei den in den Schaltplänen angegebenen Messwerten handelt es sich um Näherungswerte!
Exploded View and
Spare Parts List .................................. 4-1 … 4-2
Exploded View ............................................................................. 4-1
Spare Parts List ........................................................................... 4-2
General Section
Measuring Instruments / Equipment
Signal generator Sweep generator Oscilloscope Digital voltmeter Insulating transformer Distortion meter
General Notes
Before opening the cabinet disconnect the mains plug! Attention: Observe the ESD safety regulations
Wiring
Before disconnecting any leads and especially the earth connecting leads observe the way they are routed to the individual assemblies like the chassis, mains switch panel, keyboard control panel, picture tube panel, deflection unit, loudspeaker and so on. On completion of the repairs the leads must be laid out as originally fitted at the factory to avoid later failures or disturbances.
Carrying out Measurements
When making measurements on semi-conductors with an oscillo­scope, ensure that the test probe is set to 10:1 dividing factor. If the previous measurement was made on AC input, please note that the coupling capacitor in the oscilloscope will be charged. Discharge via the item being checked can damage the components.
Measured Values
The measured values given in the circuit diagrams are approximates!
1 - 2
GRUNDIG Service VERTIGA UMS 4600 DEC
Technische Daten
System
Spannungsversorgung:
Betriebsspannung ................................................................... 230V~
Netzfrequenz ........................................................................ 50/60Hz
Max. Leistungsaufnahme ........................................................... 28W
Leistungsaufnahme in Stand-by ................................................ ≤5W
Verstärkerteil
Ausgangsleistung:
Sinusleistung .......................................................................... 2 x 5W
Musikleistung ......................................................................... 2 x 8W
Empfangsteil
Empfangsbereich:
FM .......................................................................... 87,5 ...108,0MHz
MW ........................................................................... 522 ... 1620kHz
CD Teil
Frequenzgang ..........................................................100Hz ... 15kHz
Geräuschspannungsabstand (bewertet) ................................. ≥60dB
MP3-Features
Alben und Files ................... Max. 200 Alben, max. 500 Files pro CD
File System/File Management ............ ISO 9660 Level 1 kompatibel
Abmessungen
Abmessungen Gerät B x H x T .......................... 170 x 172 x 250mm
Abmessungen Lautsprecher B x H x T .............. 128 x 255 x 148mm
Gewicht
Gewicht Gerät ...........................................................................2,4kg
Gewicht pro Lautsprecher ........................................................0,8 kg
Technical Data
System
Power supply:
Operating voltage ................................................................... 230V~
Mains frequency ................................................................... 50/60Hz
Max. power consumption .......................................................... 28W
Power consumption in stand-by ................................................. ≤5W
Amplifier unit
Output:
Sine wave power .................................................................... 2 x 5W
Music signal power ................................................................ 2 x 8W
Receiver unit
Reception range:
FM .......................................................................... 87.5 ...108.0MHz
MW ........................................................................... 522 ... 1620kHz
CD unit
Frequency response ................................................ 100Hz ... 15kHz
Noise-voltage ratio (wtd.) ........................................................ ≥60dB
MP3 features
Albums and files: ............... Max. 200 albums, max. 500 files per CD
File system/file management .............. ISO 9660 Level 1 compatible
Dimensions
Device dimensions W x H x D ........................... 170 x 172 x 250 mm
Loudspeaker dimensions W x H x D .................. 128 x 255 x 148mm
Weight
Device weight ............................................................................ 2.4kg
Weight per loudspeaker ............................................................0.8kg
Servicehinweise
Achtung: ESD-Vorschriften beachten
Vor Öffnen des Gehäuses Netzstecker ziehen. CD-Laufwerk
Bei Ausbau der Lasereinheit oder der Servo-Leiterplatte muß vor Abziehen der Steckverbindung eine Schutzlötstelle auf der Leiter-
platte der Lasereinheit angebracht werden, um eine Zerstörung der Laserdioden durch statische Aufladung zu vermeiden.
Beim Einbau einer neuen Lasereinheit (CD-Laufwerk) muß nach Einstecken der Steckverbinder die werkseitig angebrachte Schutzlötstelle entfernt werden!
Service Hints
Attention: Observe the ESD safety regulations Disconnect the mains plug before opening the set. CD Mechanism
When removing the Laser pick-up or the Servo PCB, the Laser pick­up PCB must be provided with a protective soldered joint before
unplugging the connectors to avoid damage to the Laser diodes by static charges.
When inserting the new Laser pick-up (CD drive mechanism) the soldered joint fitted at the factory must be removed after the connectors are plugged in.
Schutzlötstelle Protective soldered joint
1 - 3
Bedienhinweise
Dieses Kapitel enthält Auszüge aus der Bedienungsanleitung. Weitergehende Informationen entnehmen Sie bitte der gerätespezifisc
1 - 4
GRUNDIG Service VERTIGA UMS 4600 DEC
hen Bedienungsanleitung, deren Materialnummer Sie in der Ersatzteilliste finden.
1 - 5
GRUNDIG Service VERTIGA UMS 4600 DEC
1 - 6
GRUNDIG Service VERTIGA UMS 4600 DEC
1 - 7
GRUNDIG Service VERTIGA UMS 4600 DEC
Operating Hints
This chapter contains excerpts from the operating instructions. For further particulars please refer to the appropriate user in
1 - 8
GRUNDIG Service VERTIGA UMS 4600 DEC
structions the part number of which is indicated in the relevant spare parts list.
1 - 9
GRUNDIG Service VERTIGA UMS 4600 DEC
Loading...