Groen DH, DHT-80 General Manual

Floor Kettles
Description
Kettle shall be a Groen Model DH-80 or DHT-80, 80­gallon stainless steel steam jacketed unit, operating with a self-contained gas heated steam source contained within the unit.
Construction
Kettle shall have a type 316 stainless steel interior and be a solid one-piece welded construction. The console and all exposed surfaces shall be stainless steel. All controls shall be mounted on the front panel except the thermostat, which is mounted on the trunnion support arm.
The kettle body shall be mounted in a heavy-duty stainless steel combination kettle support tilt trunnion, which in turn, is supported by a stainless steel enclosed base. The base shall be provided with stainless steel tubular legs with adjustable flanged feet. The enclosed support base shall contain a smooth operating, self locking tilt mechanism, and shall be of sanitary, drip­proof construction, with interior readily accessible for installation or maintenance.
The unit shall be furnished with a heavy reinforced bar rim with a welded in butterfly shaped pouring lip for maximum sanitation and durability. Faucet mounting bracket is standard.
Finish
Kettle interior shall be polished to a 180 emery grit finish. Exterior of kettle shall be finished to a bright high buff finish, ensuring maximum ease in cleaning and maintaining brilliant appearance.
A.S.M.E. Code, C.S.A (A.G.A.) Design Certified
Unit shall be ASME shop inspected, stamped and registered with the National Board for operation up to a maximum working pressure of 50 PSI. Unit shall be design certified by CSA(AGA). (Natural and Propane only.)
Sanitation
Unit shall be designed and constructed to meet NSF and known health department and sanitation codes and be NSF listed.
Drawoff
A 2” tangent drawoff shall be supplied on the DHT-80. When drawoff is specified, outlet shall be equipped with removable 1/4” perforated stainless steel strainer.
Self-Contained Steam Source
Kettle shall have a gas-heated (natural, butane, propane) self-contained steam source to provide kettle temperatures of 150 to approximately 295˚F. Unit shall be factory charged with chemically-pure water and rust inhibitors to ensure long life and minimum maintenance.
Controls
Controls shall include a thermostat, pressure gauge, safety valve, pressure limit control, water inspection window, low water cut off, a gas regulator valve and electronic ignition module. Power ON switch, Power ON indicator light, LOW WATER indicator light, and HEATING
model DH/DHT-80
Model DHT-80 shown
light are mounted on the kettle support side console. Gas supply shall shut off automatically when unit is tilted.
Performance Features
Patented fin tube burner assembly delivers 62-65% efficient combustion. 80 Gallon Model has 150,000 BTU/HR firing rate with 93,000 BTU/HR into the product.
Electronic ignition is standard on all the kettle. Unit shall be thermostatically controlled to automatically shut off when desired temperature is reached and turn on when product temperature drops below setting.
Installation
Specify natural, propane, butane, or specific propane/ butane mixture. Unit requires 1/2” IPS gas line connection and 115 volt electrical connection. No remote steam source required.
Options/Accessories
Basket inserts (TRI-BC) Lift-off cover Hinged cover kit Pan carrier Kettle brush kit Double and single pantry faucets Lip strainer 2” tangent draw-off valve with 1/4” perforated disk strainer 1/8” perforated disk strainer 1/4” perforated disk strainer Solid disk strainer Contour measuring strip Gallon etch marks
Origin of Manufacture
Kettle shall be designed and manufactured in the United States.
Stainless Steel Steam Jacketed Kettle
Floor Mounted Tilting Self-Contained Gas Heated 80-Gallon Capacity
Short Form
Groen Model DH/DHT-80 80-gallon, self-contained, gas heated (specify natural, propane, butane, or mixture) tilting, steam jacketed kettle. All stainless steel construction with type 316 stainless steel interior and reinforced bar rim, butterfly shaped pouring lip and smooth action mechanical tilt. Patented fin tube burner assembly is 62-65% efficient, with electronic ignition standard. NSF listed, ASME code constructed for 50 PSI and CSA(AGA) design certified (Natural & Propane gas only). Requires 1/2” IPS gas line and 115 volt electric service. Made in USA.
Applications
Meat Dishes Vegetables Soups Sauces Pasta Rice Pie Fillings Gravies Poultry Seafood
1055 Mendell Davis Drive, Jackson, MS 39272 888-994-7636, unifiedbrands.net
Please reference our website for the most updated product information and specifications.
Groen Floor Kettles, Page 7
150951B
Revised 07/10
30 1/4"
INCOMING GAS PRESSURE TABLE
14.0 W.C.
MAX. SUPPLY
GAS PRESSURE
4.5 W.C.
MIN. SUPPLY
GAS PRESSURE
TYPE OF GAS
NATURAL
Model DH/DHT-80
P/N 150925 REV A
12"
14 W.C.
FAUCET BRACKET
11.0 W.C.
PROPANE
OPTIONAL EXTRA COST FEATURES :
5. DIMENSIONS IN BRACKETS ( ) ARE MM.
1. 2" TANGENT SANITARY DRAW-OFF.
3. COUNTERBALANCED COVER MODEL # 51
4. OPTIONAL FAUCET WITH SWING SPOUT.
FURNISHED AS STANDARD
WALL
(305)
REAR WALL CLEARANCE
(944)
37 1/8"
37 5/8"
RIGHT SIDE VIEW
(954)
2"
2 1/2"
(769)
(BTU/HR)
FIRING RATE
(50)
(63)
OPERATING GAS PRESSURE
DH/80 150,000
FOR BOTH NATURAL AND LP
OPTIONAL FAUCET
PROPANE
NATURAL
TOP VIEW
37 1/2"
10.0 in W.C.
3.5 in W.C.
(952)
(1778 ± 76)
70" ± 3" POUR PATH
(271)
10 5/8"
OPTIONAL
2" TANGENT
DRAW-OFF
KETTLE IN
FULL TILT
POSITION
(1222)
48 1/8"
(289)
11 3/8"
(83)
3 1/4"
(219)
8 5/8"
(56)
2 1/8"
34"ID
KETTLE TILT
HANDLE
(768)
30 1/4"
4 1/2"
(114)
(135)
5 1/4"
(56)
2 1/4"
5"
(125)
(1305)
51 3/8"
FRONT VIEW
ELECTRICAL CONNECTION
7/8"(Ø22)HOLE (BACK SIDE)
(53)
4 5/8"
(116)
(1115)
43 7/8"
2 1/8" TYP.
(53)
2 1/8" TYP.
(719)
28 1/4"
3/4"
(19)
(441)
17 3/8"
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net