THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
Information contained in this document is
known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated
product information and specifications.
Page 2
OM-DEES
IMPORTANT — READ FIRST — IMPORTANT
WARNING:BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC
WARNING:THIS UNIT IS INTENDED FOR USE IN THE COMMERCIAL HEATING, COOKING AND
HOLDING OF WATER AND FOOD PRODUCTS, PER THE INSTRUCTIONS
CONTAINED IN THIS MANUAL. ANY OTHER USE COULD RESULT IN SERIOUS
PERSONAL INJURY OR DAMAGE TO THE EQUIPMENT AND WILL VOID
WARRANTY.
WARNING:KETTLE MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH
ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN RESULT IN
INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
DANGER:ELECTRICALLY GROUND THE UNIT AT THE TERMINAL PROVIDED. FAILURE TO
GROUND UNIT COULD RESULT IN ELECTROCUTION AND DEATH.
WARNING:AVOID ALL DIRECT CONTACT WITH HOT EQUIPMENT SURFACES. DIRECT SKIN
CONTACT COULD RESULT IN SEVERE BURNS.
WARNING:AVOID ALL DIRECT CONTACT WITH HOT FOOD OR WATER IN THE KETTLE.
DIRECT CONTACT COULD RESULT IN SEVERE BURNS.
CAUTION:DO NOT OVER FILL THE KETTLE WHEN COOKING, HOLDING OR CLEANING.
KEEP LIQUIDS A MINIMUM OF 2-3” (5-8 cm) BELOW THE KETTLE BODY RIM TO
ALLOW CLEARANCE FOR STIRRING, BOILING AND SAFE PRODUCT TRANSFER.
WARNING:TAKE SPECIAL CARE TO AVOID CONTACT WITH HOT KETTLE BODY OR HOT
PRODUCT WHEN ADDING INGREDIENTS, STIRRING OR TRANSFERRING
PRODUCT TO ANOTHER CONTAINER.
WARNING:WHEN TILTING KETTLE FOR PRODUCT TRANSFER:
1) USE CONTAINER DEEP ENOUGH TO CONTAIN AND MINIMIZE PRODUCT
SPLASHING.
2) PLACE CONTAINER ON STABLE, FLAT SURFACE, AS CLOSE TO KETTLE AS
POSSIBLE.
3) DO NOT OVER FILL CONTAINER. AVOID DIRECT SKIN CONTACT WITH HOT
CONTAINER AND ITS CONTENTS.
WARNING:FAILURE TO CHECK PRESSURE RELIEF VALVE OPERATION PERIODICALLY
COULD RESULT IN PERSONAL INJURY AND/OR DAMAGE TO EQUIPMENT.
WARNING:DO NOT CONNECT ANY PIPING TO THE PRESSURE RELIEF VALVE. IT MUST BE
FREE TO VENT STEAM AS NEEDED. TO AVOID BURNS FROM THE VENTED
STEAM THE VALVE DISCHARGE SHOULD POINT DOWNWARD. IMPROPER
INSTALLATION WILL VOID WARRANTY.
WARNING:DO NOT STAND OR APPLY UNNECESSARY WEIGHT OR PRESSURE ON THE
KETTLE FRONT OR POURING LIP. THIS COULD RESULT IN THE OVERLOAD AND
FAILURE OF THE TILT MECHANISM, AND POSSIBLE SERIOUS INJURY AND
BURNS TO THE OPERATOR AND OTHERS.
NOTICE:NEVER LEAVE SANITIZER IN CONTACT WITH STAINLESS STEEL SURFACES
LONGER THAN 10 MINUTES. LONGER CONTACT CAN CAUSE CORROSION.
WARNING:WHEN TESTING, AVOID ANY EXPOSURE TO THE STEAM BLOWING OUT OF THE
PRESSURE RELIEF VALVE. DIRECT CONTACT COULD RESULT IN SEVERE
BURNS.
WARNING:TO AVOID INJURY, READ AND FOLLOW ALL PRECAUTIONS STATED ON THE
LABEL OF THE WATER TREATMENT COMPOUND.
2
Page 3
OM-DEES
IMPORTANT — READ FIRST — IMPORTANT
WARNING:KEEP WATER AND SOLUTIONS OUT OF CONTROLS AND ELECTRICAL
EQUIPMENT. NEVER USE A HIGH PRESSURE HOSE TO CLEAN KETTLE
SURFACES.
CAUTION:MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES
AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN. WEAR RUBBER GLOVES,
GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ
THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE
CLEANER TO BE USED.
CAUTION:USE
IMPORTANT: SERVICE PERFORMED BY OTHER THAN FACTORY AUTHORIZED PERSONNEL
The Groen DEES is a floor-mounted, tilting,
steam jacketed kettle with a thermostatically
controlled, self-contained, electrically-heated
steam supply and appropriate controls, mounted
on a sturdy base.
The body of the DEES Kettle is constructed of
stainless steel, welded into one solid piece. The
kettle is furnished with a reinforced rim and a
butterfly shaped pouring lip. It has a steam jacket
rated for working pressures up to 50 PSI. Kettle
finish is 180 emery grit on the inside and bright
semi-deluxe on the outside.
The kettle can be tilted with a hand crank to pour
out its contents. Stainless steel panels enclose
the controls and the base. Four stainless steel,
tubular legs support the unit. Bullet feet on each
of the legs can be adjusted to level the kettle.
DEES/T units include a two inch tangent draw off
valve.
KETTLE CHARACTERISTICS
DEES-40 & DEES/T-40
Kettle Capacity40 gal (150l)
Kettle Diameter30 in (76 cm)
Rim Height39 in (99 cm)
Total Width47 in (119 cm)
Front to Back35 in (90 cm)
A built-in steam generator, sized for the kettle
capacity and heated by electricity, delivers steam
into the jacket. “Airless” operation of the steam
jacket permits uniform, efficient heating at
temperatures as low as 150°F and as high as
298°F. In addition to the adjustable thermostat
for operating control, the unit has a tilt cut-off
switch, low water cut-off, safety valve, and highlimit pressure switch as safety features. A
heating indicator light, pressure gauge, and sight
glass are provided for monitoring kettle
operation.
A single electrical connection is required for
installation. The unit may be ordered for use with
208/240, 400 or 480 volt power. All kettles are
wired for three-phase operation. Single-phase
units are also available.
Pressure Gauge
Water Gauge Glass
Thermostat Dial
Indicator Light
Tilting Crank
Optional Draw-Off Valve
5
Page 6
OM-DEES
Optional equipment available with DEE/4 kettles:
1. 2" diameter tangent draw-off (product valve)*
2. Strainers, solid disk, 1/4" or 1/8"
perforations.
3. Lift-off or counterbalanced cover*
4. Water fill faucets
Inspection & Unpacking
The unit will arrive in a heavy shipping carton
and will be bolted or banded to a skid.
Immediately upon receipt, inspect the carton
carefully for exterior damage.
CAUTION
SHIPPING STRAPS ARE UNDER TENSION
AND CAN SNAP BACK WHEN CUT. TAKE
CARE TO AVOID PERSONAL INJURY OR
DAMAGE TO THE UNIT BY STAPLES LEFT
IN THE WALLS OF THE CARTON.
Carefully cut any polyester straps around the
carton and detach the sides of the box from the
skid. Pull the carton up off the unit.
Thoroughly inspect the unit for concealed
damage. Report any shipping damage or
incorrect shipments to the delivery agent.
5. TRI-BC basket cooking system
6. Powered agitators (TA/3 or INA/2)*
7. Kettle brush kit
8. 316 Stainless Steel interior*
9. Gallon etch marks*
10. Automatic metered water filters.
* Factory Installed Options.
Write down the model number, serial number,
and installation date, and retain this information
for future reference. Space for these entries is
provided at the top of the Service Log at the
back of this manual. Keep this manual on file
and available for operators to use.
CAUTION
THIS UNIT IS VERY HEAVY. INSTALLER
SHOULD OBTAIN HELP AS NEEDED TO
LIFT THIS WEIGHT SAFELY.
When installation is to begin, carefully cut any
straps which hold the unit on the skid. Lift the
unit straight up off the skid. Examine packing
materials to be sure loose parts are not
discarded with the materials.
6
Page 7
Installation
The Groen Kettle is provided with complete
internal wiring and is ready for immediate
connection. Wiring diagrams are provided in this
manual and on the inside of the control housing
service panel. Any mechanical or electrical
changes must be approved by Groen’s Food
Service Engineering Department.
WARNING
INSTALLATION OF THE KETTLE MUST BE
DONE BY PERSONNEL QUALIFIED TO
WORK WITH ELECTRICITY. IMPROPER
INSTALLATION CAN RESULT IN INJURY
TO PERSONNEL AND/OR DAMAGE TO
EQUIPMENT.
The completed unit has been operated at the
factory to test all controls and heater elements.
1. Set the kettle in place and level it by turning
the bullet feet to adjust leg length. Allow
clearance around the unit for cleaning,
maintenance and service.
OM-DEES
4. Provide electrical power specified on the
equipment electrical information plate.
Observe local codes an/or The National
Electrical Code in accordance with
ANSI/NFPA 70 - (current edition.).
5. The equipment is shipped ready for three
phase operation. Refer to the wiring diagram
for single phase operation.
6. Bringing the electrical service through the
entrance at the rear of the support housing
with one inch conduit, making a watertight
connection with the incoming lines. Observe
local codes and/or the National Electrical
Code in compliance with ANSI/NFPA 70
(latest edition). When there is a choice
between applicable codes, Groen
recommends following the more stringent
code. (A BX connection is not
recommended.)
2. Confirm that the jacket water level is at the
mid point of sight glass. If the level is low,
follow the instructions under “Jacket Filling
and Water Treatment,” Page 13.
WARNING
DO NOT CONNECT ANY PIPING TO THE
PRESSURE RELIEF VALVE. THE VALVE
MUST BE FREE TO VENT STEAM AS
NEEDED. IMPROPER INSTALLATION
WILL VOID THE WARRANTY! THE ELBOW
ATTACHED TO THE SAFETY VALVE MUST
POINT TO THE FLOOR.
3. The open end of the
elbow on the outlet of
the pressure relief
valve must face
downward. If it does
not, turn it to the
correct position.
ELECTRICAL SPECIFICATIONS*
DANGER
ELECTRICALLY GROUND THE UNIT AT
THE TERMINAL PROVIDED. FAILURE TO
GROUND UNIT COULD RESULT IN
ELECTROCUTION AND DEATH.
7. Electrically ground the unit at the terminal
provided.
8. Check the following to confirm that your
DEES kettle is properly installed:
•Room for cleaning and servicing
•The kettle is level
•The correct amount of water is in the
kettle jacket
•Pressure relief valve is pointed down
•Unit is connected with a waterproof
supply of the proper voltage, phase and
amperage rating
DEES-40
KWAMP
208 Volts2159
240 Volts2461
480 Volts2429
400 Volts2435
*All three phase. Single phase is also available.
7
Page 8
OM-DEES
Initial Start-Up
IMPORTANT:
BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING
INSTRUCTIONS, CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL.
Now that the kettle has been installed, you
should test it to ensure that the unit is operating
correctly.
1. Remove all literature and packing materials
from inside and outside of the unit.
2. If the unit is equipped with a draw-off valve
(product outlet), clean out any material which
might clog or damage the draw-off.
3. Confirm that the tilting mechanism is
operating properly by tilting the kettle
through its full range. Then return the kettle
to the upright position.
4. Turn on the electrical service to the unit.
5. Pour 1-2 quarts of water into the kettle.
6. Following “To Start Kettle” instructions in the
“Operation” section of this manual, begin
heating the water at the highest thermostat
setting. The heating indicator light should
come on immediately, and heating should
continue until the water boils.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT
COULD RESULT IN SEVERE BURNS.
AVOID ALL DIRECT CONTACT WITH HOT
FOOD OR WATER IN THE KETTLE.
DIRECT CONTACT COULD RESULT IN
SEVERE BURNS.
5. To shut down the unit, turn the thermostat
dial to “OFF”.
If the unit functions as described above, it is
ready for use. If the unit does not function as
described, contact your local Groen Certified
Service Agency.
The pressure gauge should show a vacuum
of 20 to 30 inches when the kettle is cold.
8
Page 9
Pressure Gauge
OM-DEES
Operation
that the kettle is being held at the set
temperature. Once in each cycle the
contactors in the support housing will
make a clicking sound. This is normal.
Water Gauge Glass
The operator controls kettle heating with the
thermostat dial. The dial turns heating element
power on or off and sets the kettle operating
temperature.
A. Controls
Operator controls for the DEES kettle are:
1. Thermostat dial, which turns the thermostat
Thermostat Dial
Optional Draw-Off
Valve
on or off, and sets the kettle temperature.
Tilting Crank
2. To Transfer Product or Empty Kettle:
a. The kettle is tilted by means of the crank
on the front of the control housing. The
kettle remains in the position to which
tilted until cranked again.
b. Product may also be transfered by means
of the optional draw-off valve if the kettle
is so equipped.
3. To Stop Kettle Heating:
a. Turn thermostat dial to OFF.
b. For a prolonged shut-down:
1. Follow the procedure above.
2. Disconnect electric power from the
unit.
2. Tilting crank, used to tilt the kettle body.
3. Indicator Lights to alert operator of unit
condition. Heat Indicator - indicates that main
power is on to produce steam in the kettle
jacket.
B. Operating Instructions
1. To Start Kettle
a. EVERY DAY make sure that the jacket
water level is in the center of the sight
glass. If the level is too low, see
“Jacket Filling and Water Treatment”
on page 13.
b. Check the pressure gauge. If the
gauge does not show 20 to 30 inches
of vacuum (that is, a reading of 20 to
30 below 0), see “Jacket Vacuum” on
page 13.
c. Turn on the electrical power to the
unit.
d. Turn the thermostat dial to the desired
setting. The heating indicator light-
Indicates that the kettle is heating.
Cycling of the light on and off shows
CAUTION
DO NOT OVERFILL THE KETTLE WHEN
COOKING, HOLDING OR CLEANING. KEEP
LIQUIDS AT LEAST 2-3” (5-8 cm) BELOW
THE KETTLE BODY RIM TO ALLOW
CLEARANCE FOR STIRRING, BOILING
PRODUCT AND SAFE TRANSFER.
9
Page 10
OM-DEES
WARNING
WHEN TILTING KETTLE FOR PRODUCT
TRANSFER:
1) WEAR PROTECTIVE OVEN MITT AND
PROTECTIVE APRON.
2) USE DEEP CONTAINER TO CONTAIN
AND MINIMIZE PRODUCT SPLASHING.
3) PLACE CONTAINER ON STABLE, FLAT
SURFACE, AS CLOSE TO KETTLE AS
POSSIBLE.
4) STAND TO LEFT OR RIGHT OF KETTLE
WHILE POURING — NOT DIRECTLY IN
POUR PATH OF HOT CONTENTS.
5) POUR SLOWLY, MAINTAINING
CONTROL OF KETTLE AT ALL TIMES,
AND RETURN KETTLE BODY TO
UPRIGHT POSITION AFTER CONTAINER
IS FILLED OR TRANSFER IS
COMPLETE.
6) DO NOT OVERFILL CONTAINER. AVOID
DIRECT SKIN CONTACT WITH HOT
CONTAINER AND ITS CONTENTS.
Use Of Common Accessories
1. Lift-Off or Counterbalanced Cover
As with stock pot cooking, an optional cover
can speed up the heating of water and food
products. A cover helps retain heat and
reduces the heat and humidity released into
the kitchen. Using a cover can reduce some
product cook times and help maintain the
temperature, color and texture of products
being held or simmered for longer periods.
Be sure the handle is secure on the lift-off
cover before using. ALWAYS use the handle
to place or remove cover from the kettle.
Wear protective oven mitts and a protective
apron.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT
COULD RESULT IN SEVERE BURNS.
AVOID ALL DIRECT CONTACT WITH HOT
FOOD OR WATER IN THE KETTLE. DIRECT
CONTACT COULD RESULT IN SEVERE
BURNS.
TAKE SPECIAL CARE TO AVOID CONTACT
WITH HOT KETTLE BODY OR HOT
PRODUCT, WHEN ADDING INGREDIENTS,
STIRRING OR TRANSFERRING PRODUCT
TO ANOTHER CONTAINER.
CAUTION
KEEP FLOORS IN FRONT OF THE KETTLE
SPILLS OCCUR, CLEAN AT ONCE TO
AVOID SPILLS.
When putting a lift-off cover on the kettle,
position it on top of kettle rim, with its flat
edge facing the pouring lip.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
SURFACES. DIRECT SKIN CONTACT
COULD RESULT IN SEVERE BURNS.
AVOID ALL DIRECT CONTACT WITH HOT
FOOD OR WATER IN THE KETTLE.
DIRECT CONTACT COULD RESULT IN
SEVERE BURNS.
When removing the lift-off cover:
a) Firmly grasp the handle
b) Lift rear
edge (farthest from operator) 12” (3-5 cm) to allow steam and water
vapor to escape the cooking vessel.
Wait 2-3 seconds.
c) Tilt cover to 45-60° angle to allow any
hot condensate or product to roll off
cover back into kettle.
10
d) Remove cover, ensuring that any
remaining hot condensate or product
does not drip on operator, floor or work
surfaces.
Page 11
e) Place cover on safe, flat, sanitary, out-of-
the-way surface, or return to kettle.
OM-DEES
lip. Wear protective oven mitts and
protective apron.
CAUTION
DO NOT TILT KETTLE WITH LIFT-OFF
COVER IN PLACE. COVER MAY SLIDE
OFF, CAUSING INJURY TO OPERATOR.
2. Basket Insert
An optional kettle basket insert set can assist
in cooking water-boiled products including
eggs, potatoes, vegetables, shell fish, pasta
and rice. The nylon mesh liner must be used
for products smaller than the basket mesh
size, (approximately 1/4” (6 mm). This
includes rice and small pasta shapes.
Tips For Use.
a) Allow for displacement of the 3 baskets
and product. This may mean only filling
the kettle half way. Test baskets and
product displacement with the kettle OFF,
and with cold water in the kettle.
f)Allow hot water to fully drain from
product, before moving basket away
from the kettle. Do not rest baskets on
kettle rim or pouring lip. If baskets are
too heavy for individual to lift and safely
move, get help. Remove product
immediately from basket into another
container, being sure to avoid contact
with hot product and hot basket or. . .
g) Place baskets with food on a stable, flat
surface, inside a solid steamer or bake
pan, to catch any remaining hot water
draining from product.
CAUTION
DO NOT OVERFILL THE KETTLE WHEN
COOKING, HOLDING ORCLEANING.
KEEP LIQUIDS AT LEAST 2-3” (5-8 cm)
BELOW THE KETTLE RIM TO ALLOW
CLEARANCE FOR STIRRING, BOILING
AND SAFE PRODUCT TRANSFER.
WARNING
AVOID ALL DIRECT CONTACT WITH HOT
FOOD OR WATER IN THE KETTLE.
DIRECT CONTACT COULD RESULT IN
SEVERE BURNS.
b) Load baskets on a level, stable work
surface.
c) Lift loaded baskets with both hands. Get
help from another person if the basket is
too heavy for safe handling.
d) Slowly lower product into kettle and
securely hook the basket to the “Y” frame.
e) When removing baskets with cooked
product, lift straight up, ensuring basket
bottoms clear the kettle rim and pouring
11
Page 12
OM-DEES
Sequence of Operation
The following “action-reaction” outline is provided
to help the user understand how the equipment
works.
When the operator starts up the kettle by turning
the operating thermostat dial from “OFF” to a
desired setting, the thermostat switch closes.
This lights up the heating indicator light and
causes the contactors to close, allowing power to
flow to heating elements.
When the temperature of the steam jacket
reaches the value corresponding to the dial
setting, the thermostat switch opens. This turns
off the heating indicator light and causes the
contactors to open, stopping the power to the
heaters.
As soon as the thermostat senses that the kettle
is cooling below the set point, the thermostat
switch closes, the heating indicator light comes
on, the contactors close, and the heaters come
on again. On-off cycling continues, keeping the
kettle at the set temperature.
This is why the heating indicator light cycles on
and off during normal operation. Every time the
kettle is tilted, the tilt cut-off switch interrupts the
power supply to the heaters, so that the heating
elements will not operate while not submerged in
the jacket water.
The kettle has the following safety features in
addition to the 90-second ignition timer:
1. Low water cutoff relay that will shut off gas
supplies to all burners until the jacket water
level is corrected.
2. High limit pressure switch, set to open at
about 46 PSI and to shut down the burners
until jacket pressure is decreased.
3. Pressure relief valve, which will release
steam if jacket pressure exceeds 50 PSI.
4. Tilt switch, which shuts off all burners when
the kettle is tilted.
5. Gas pressure regulator built into the gas
control valve.
If steam pressure greater than 50 PSI is
generated in the jacket, the safety valve will open
and relieve the excess pressure.
If the jacket water level gets too low before the
heating elements overheat, the high-limit control
will open and shut off power to the elements until
the kettle cools.
Setting the operation thermostat dial to “OFF”
shuts down all control and heating circuits.
12
Page 13
OM-DEES
Maintenance
NOTICE: Contact Groen or an authorized Groen representative when repairs are required.
1. Periodic Maintenance
A Service Log is provided at the back of this
manual with the warranty information. Each
time maintenance is performed on your
Groen kettle, enter the date on which the
work was done, what was done, and who did
it. Keep this manual on file and available for
operators to use.
Periodic inspection will minimize equipment
down time and increase the efficiency of
operation. The following points should be
checked:
[BY OPERATOR]
a. Check the pressure/vacuum gauge
c. Carefully test the pressure relief valve at
least twice each month. With the kettle
operating at 15 psi (105 kPa),pull the test
lever and let it snap back to its closed
position. If there is little discharge (mostly
air), and the pressure gauge drops back
to zero PSI, allow the pressure to build
back to five PSI and repeat the
procedure. (Tip: Using a screwdriver or
other implement to pull the ring will help
you avoid contact with the steam.
WARNING
WHEN TESTING, AVOID ANY EXPOSURE
TO THE STEAM BLOWING OUT OF THE
SAFETY VALVE. DIRECT CONTACT
COULD RESULT IN SEVERE BURNS.
The pressure gauge should show a vacuum
of 20 to 30 inches when the kettle is cold.
every day. The gauge should show a
vacuum of 20 to 30 inches, when the
kettle is cold. If it does not, see “Jacket
Vacuum” on page 13.
b. Also check the jacket water level every
day. It should be between the marks on
the gauge glass. If the level is low, see
“Jacket Filling and Water Treatment” on
page 13.
Correct Water Level
Test the safety valve at least twice
Test the pressure relief valve at least
monthly.
twice monthly.
[BY SERVICE TECHNICIAN]
d. Electrical wiring should be kept securely
connected and in good condition.
e. The inside of the support housing should
be kept clean.
13
Page 14
OM-DEES
f. The gear housing has fittings for lubrication
of moving parts. The gears do not run in oil,
so periodic lubrication with grease is
necessary.
g. Frequency of lubrication depends on
operating conditions, but it should be done at
least once every six months.
h. Use a #2 grade LGI lithium grease to add
grease through Zerk fittings on gear housing
until it flows out of the bearings around the
trunnion shaft.
j.Keep electrical wiring and connections in
good condition.
k. Keep the inside of the control console clean
and dry.
i.Place liberal amounts of grease on the gear
to cover the arc that is in contact with the
worm gear.
Liberally grease the wheel where it contacts the
worm gear.
14
Page 15
2. Jacket Vacuum/Removing Air from
Jacket
When the kettle is cold, a positive pressure
reading on the pressure/vacuum gauge or a
reading near zero indicates that there is air
in the jacket. Air in the jacket acts as an
insulator, and slows kettle heating.
To remove air:
a. Start the unit. (Be sure there is water or
product in the kettle when heating).
b. When the pressure/vacuum gauge
reaches a positive pressure reading of
five PSI, release the trapped air and
steam by pulling up the safety valve ring
for about five seconds. Repeat this step
three or four times. Then let the pull ring
snap back into the closed position.
c. If there is little discharge (mostly air),
and the pressure gauge drops back to
zero PSI, allow the pressure to build
back to five PSI and repeat the
procedure.
d. Once steam has been vented from the
jacket as described in b, above, remove
the hot water from the kettle and replace
it with cold. This will condense steam in
the kettle jacket, and the pressure gauge
should show a reading of 20 to 30
inches mercury (Hg) below zero. If it
does not, or if the vacuum is leaking
down, contact a Groen authorized
service agency to correct the problem.
Pressure Gauge
Safety Valve
OM-DEES
water that ran out of the jacket, prepare more
treated water as directed in “Water Treatment
Procedure,” below.
Pipe Plug
Check Valve
Test the safety valve at least twice monthly.
a. Allow the kettle to cool completely. The
procedure will be easier with the kettle under
vacuum ( pressure gauge reading below
zero).
b. Allow the kettle to cool completely. Remove
the pipe plug from the jacket fill assembly.
Pour in the distilled or treated water. Using a
funnel will help you in this process. Hold the
pressure relief valve open while you pour, to
let air escape from the jacket. Continue
adding water until the water level rises to the
center of the round sight glass.
c. Position a funnel in the opening and fill it with
properly treated water.
d. Air that gets into the jacket during the filling
operation must be removed, because it will
make heating less efficient. Follow the
procedure in Jacket Vacuum/Removing AirFrom Jacket above, to restore a negative
pressure reading.
4. Water Treatment Procedure
3. Jacket Filling and Water Treatment
The jacket was charged at the factory with
the proper amount of treated water. You may
need to restore this water, either because it
was lost as venting steam or by draining. If
you are replacing water lost as steam, use
distilled water. If you are replacing treated
(1) Obtain water treatment compound and a
pH test kit from your authorized Groen
parts distributor.
WARNING
TO AVOID INJURY, READ AND FOLLOW
ALL PRECAUTIONS STATED ON THE
LABEL OF THE WATER TREATMENT
COMPOUND.
(2) Fill a mixing container with the measured
amount of water required. (See table).
Distilled water is recommended.
15
Page 16
OM-DEES
Kettle ModelJacket Capacity
DEES-40, DEES/T-404 Gallons
(3) Hang a strip of pH test paper on the rim
of the container, with about 1 inch of the
strip below the surface of the water.
(4) Measure the water treatment compound
(One way to do this is to add the
compound from a measuring cup.)
(5) Stir the water continuously, while you
slowly add water treatment compound,
until the water reaches a pH between
10.5 and 11.5. Judge the pH by
frequently comparing the test strip color
with the color chart provided in the pH
test kit. If you are color blind use an
electroanalytical instrument to measure
the pH level or have a person who is not
color blind read the test strip color level.
(6) Record the exact amounts of water and
treatment compound used. These
amounts may be used again, if the same
water sources and compound are used
in the future. However, it is best to check
the pH each time treated water is
prepared.
16
Page 17
Cleaning
OM-DEES
1. Suggested Tools
a. Cleaner, such as Klenzade HC-10 or
HC-32 from ECOLAB, Inc.
b. Kettle brushes in good condition.
c. Sanitizer such as Klenzade XY-12.
d. Film remover such as Klenzade LC-30.
e. Groen Spray Degreaser (p/n 114801)
f.Groen DeLimer/Descaler (p/n 114800)
2. Precautions
Before cleaning, shut off the kettle by turning
the thermostat dial to “OFF,” and shut off all
electric power to the unit at a remote switch,
such as the circuit breaker.
WARNING
KEEP WATER AND SOLUTIONS AWAY
FROM CONTROLS AND ELECTRICAL
EQUIPMENT. NEVER SPRAY THE
SUPPORT HOUSING OR ELECTRICAL
CONNECTIONS.
d. Rinse the kettle thoroughly with hot water,
then drain completely.
e. As part of the daily cleaning program, clean
soiled external and internal surfaces.
Remember to check the sides of the unit and
control housing.
f.To remove stuck materials, use a brush,
sponge, cloth, plastic or rubber scraper, or
plastic wool with the cleaning solution. To
reduce effort required in washing, let the
detergent solution sit in the kettle and soak
into the residue. Do NOT use abrasive
materials or metal tools that might scratch
the surface. Scratches make the surface
harder to clean and provide places for
bacteria to grow.
Do NOT use steel wool, which may leave
particles in the surface and cause eventual
corrosion and pitting.
CAUTION
MOST CLEANERS ARE HARMFUL TO THE
SKIN, EYES, MUCOUS MEMBRANES, AND
CLOTHING. PRECAUTIONS SHOULD BE
TAKEN. WEAR RUBBER GLOVES,
GOGGLES OR FACE SHIELD, AND
PROTECTIVE CLOTHING. READ THE
WARNINGS AND FOLLOW THE
DIRECTIONS ON THE LABEL OF THE
CLEANER CAREFULLY.
3. Procedure
a. Clean food-contact surfaces as soon as
possible after use. If the unit is in continuous
use, thoroughly clean and sanitize the interior
and exterior at least once every 12 hours.
b. Scrape and flush out food residues. Be
careful not to scratch the kettle with metal
implements.
CAUTION
NEVER LEAVE A SANITIZER IN CONTACT
WITH STAINLESS STEEL SURFACES
LONGER THAN 30 MINUTES. LONGER
CONTACT CAN CAUSE CORROSION.
c. Prepare a hot solution of the detergent/
cleaning compound as instructed by the
supplier. Clean the unit thoroughly. A cloth
moistened with cleaning solution can be used
to clean controls, housings, and electrical
conduits.
Scrapers or steel wool can harm the kettle
surface.
Use only a sponge, cloth or plastic brush to
clean the kettle.
17
Page 18
OM-DEES
g. The outside of the unit may be polished
with a stainless steel cleaner such as
“Zepper” from Zep Manufacturing Co.
h.h. When equipment needs to be sanitized,
use a solution equivalent to one that
supplies 200 parts per million available
chlorine. Obtain advice on sanitizing
agents from your supplier of sanitizing
products. Following the supplier’s
instructions, apply the agent after the unit
has been cleaned and drained. Rinse off
the sanitizer thoroughly.
i.It is recommended that each piece of
equipment be sanitized just before use.
i.If there is difficulty removing mineral
deposits or a film left by hard water or
food residues, clean the kettle thoroughly
and then use a deliming agent, like
Groen Delimer/Descaler (Part Number
114800) or Lime-Away from Ecolab, in
accordance with the manufacturer’s
directions. Rinse and drain the unit
before further use.
NOTICE
NEVER LEAVE A CHLORINE SANITIZER IN
CONTACT WITH STAINLESS STEEL
SURFACES LONGER THAN 30 MINUTES.
LONGER CONTACT CAN CAUSE STAINING
AND CORROSION.
j.If cleaning problems persist, contact your
cleaning product representative for
assistance. The supplier has a trained
technical staff with laboratory facilities to
serve you.
Troubleshooting
Your Groen kettle is designed to operate smoothly and efficiently if properly maintained. However, the
following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the
service panel and in this manual. If an item on the list is followed by
qualified service representative.
USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR
AUTHORIZED DISTRIBUTORS CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE
EQUIPMENT AND WILL VOID ALL WARRANTIES.
SYMPTOMWHOWHAT TO CHECK
<<<<indicates items which must be performed by an authorized technician.
Kettle will not heat, and heating indicator
will not come on.
Kettle will not heat, but heating indicator
comes on.
Kettle continues heating after it reaches
the desired temperature
Usera. Electric power supply to the unit.
b. Water level in jacket.
Auth
Service
Rep Only
Usera. For air in the jacket. See “Jacket Vacuum” in
Auth
Service
Rep Only
Usera. Thermostat dial setting.
Auth
Service
Rep Only
c. Control circuit fuses. Replace a blown fuse
only with a fuse of the same AMP rating.
d. For loose or broken wires. <
e. Tilt cut-off switch. <
f. That pressure switch is open. <
g. Operation of variable thermostat. <
h. Low water cutoff. <
the Maintenance section of this manual.
b. Contactor.
c. Heater elements with ohmmeter for ground
short or open element. If element is defective,
call Groen.
b. Thermostat circuit for short.
c. Thermostat operation. The thermostat should
click when the dial is rotated above and below
the setting for the temperature of the kettle.
d. Contactor, to determine whether it is energized
or stuck.
<<<<, the work should be done by a
<
<
<
<
<
<
18
Page 19
OM-DEES
SYMPTOMWHOWHAT TO CHECK
<<<<indicates items which must be performed by an authorized technician.
Kettle stops heating before it reaches the
desired temperature.
Kettle heats slowlyUsera. For air in the jacket. See “Jacket Vacuum” in
Pressure relief valve pops.Usera. For air in the jacket. See “Jacket Vacuum” in
Pressure relief valve leaks a small
amount of steam when the kettle is
operating.
Kettle is hard to tilt.Auth
Usera. Thermostat dial setting.
Auth
Service
Rep Only
Auth
Service
Rep Only
Auth
Service
Rep Only
Usera. For contamination that prevents seating of
Auth
Service
Rep Only
Service
Rep Only
b. Thermostat calibration.
c. Thermostat operation. The thermostat should
click when the dial is rotated above and below
the setting for the temperature of the kettle.
the “Maintenance” section of this manual.
b. Heater elements with ohmmeter for ground
short or open element. If an element is
defective, call Groen.
c. Voltage of main power source. <
the “Maintenance” section of this manual.
b. Whether kettle was being heated empty when
valve popped.
c. Pressure switch setting.
d. Thermostat operation. Thermostat should click
when the dial is rotated above and below the
setting for the temperature of the kettle.
e. Pressure relief valve. If the valve pops at
pressures below 48 PSI, replace it.
f. Contactor, to determine whether it is de-
energized.
valve. With full pressure in the jacket, pull the
lever all the way briefly to blow the valve clean,
then let the lever snap back to seat the valve.
b. Safety valve for defects. Replace any defective
valve with an identical valve.
a. Tilting gear and worm for contamination and for
proper alignment and lubrication.
<
<
<
<
<
<
<
<
<
19
Page 20
OM-DEES
Parts List
To order parts, contact your Groen Certified Service Agency. Supply the model designation, part description, part
number, quantity, and, where applicable, voltage and phase.
20
Page 21
OM-DEES
Parts List
KeyDescriptionPart No.KeyDescriptionPart
1Wing Nut #10-2400902829 Gear 3 “ Bore013609
2Valve Handle00902930 Crank Handle013617
3Bonnet00904731 Shaft Handwheel013624
4Rubber “O” Ring00903432 Spacer 3: Sch 40013625
5Valve Stem00904833 Water Level Control Board122192
6Hex Nut00935434 Fuse Holder Type 3AG (208/240 units) 077854
7Body Valve009045Fuse Holder (480 Units)077840
8Piping Water Fill Asm.13939635 Fuse 3.0 Amp Type 3 AG (208/240
units)
9Relief Valve With Gauge Asm.139395Fuse 6.0 Amp (480 units)119823
10 Thermostat00973036 PC Board Mounting Post099901
25 Shim 1 3/8 x .010 Thk012039
26 Set Screw 5/16 x 3/4 Lg012060
27 Roll Pin 1/4 Dia x 1012614
28Internal Retaining Ring013483
Note: To order a new contactor, specify the part number on the old contactor.
077853
No.
21
Page 22
OM-DEES
Electrical Schematics
22
Page 23
Electrical Schematics
OM-DEES
208-230/240 V, 3 PH
23
Page 24
OM-DEES
Electrical Schematics
480 V, 3 PH DEES-40
24
Page 25
OM-DEES
Service Log
Model No. _______________________________Purchased From _________________________
Serial No. _______________________________Location ________________________________
Date Purchased __________________________Date Installed ___________________________
Purchase Order No. ______________________For Service Call __________________________
DateService PerformedPerformed By
25
Page 26
OM-DEES
Limited Warranty
To Commercial Purchasers *
(Domestic U.S., Hawaii &
Canadian Sales Only)
Groen Foodservice Equipment ("Groen Equipment") has been skillfully manufactured, carefully inspected
and packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects
in material and workmanship for (12) twelve months with the following conditions and subject to the
following limitations.
I.This parts and labor warranty is limited to Groen Equipment sold to the original commercial
purchaser/users (but not original equipment manufacturers), at its original place of installation in the
continental United States, Hawaii and Canada.
II. Damage during shipment is to be reported to the carrier, is not covered under this warranty, and is
the sole responsibility of purchaser/user.
III. Groen, or an authorized service representative, will repair or replace, at Groen's sole election, any
Groen Equipment, including but not limited to, drawoff valves, safety valves, gas and electric
components, found to be defective during the warranty period. As to warranty service in the
territory described above, Groen will absorb labor and portal to portal transportation costs (time &
mileage) for the first twelve (12) months from date of installation or fifteen (15) months from date of
shipment from Groen.
IV. This warranty does not cover boiler maintenance, calibration, periodic adjustments as specified in
operating instructions or manuals, and consumable parts such as scraper blades, gaskets, packing,
etc., or labor costs incurred for removal of adjacent equipment or objects to gain access to Groen
Equipment. This warranty does not cover defects caused by improper installation, abuse, careless
operation, or improper maintenance of equipment. This warranty does not cover damage caused
by poor water quality or improper boiler maintenance.
V. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY
DISCLAIMED. THE REMEDIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN NO EVENT
SHALL GROEN BE LIABLE FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES
FOR THE BREACH OR DELAY IN PERFORMANCE OF THIS WARRANTY.
VI. Groen Equipment is for commercial use only. If sold as a component of another (O.E.M.)
manufacturer's equipment, or if used as a consumer product, such Equipment is sold AS IS and
without any warranty.
* (Covers All Foodservice Equipment Ordered After October 1, 1995)