Rennes, France
Rue du Clos Courtel
Cesson-Sevigne, Cedex
France
Technopole Brest Iroise
CS 73808
29238 Brest Cedex 3
France
17 rue du Petit Albi-BP 8244
95801 Cergy Pontoise
Cergy, France
2300 South Decker Lake Blvd.
Salt Lake City, UT 84119
United States
7140 Baymeadows Way
Suite 101
Jacksonville, FL 32256
United States
Including its implementation, meets the requirements of the standard:
ISO 9001:2000
Scope:
The design, manufacture and support of video hardware and software products and
related systems.
This Certificate is valid until: June 14, 2009
This Certificate is valid as of: August 30, 2006
Certified for the first time: June 14, 2000
H. Pierre Sallé
President
KEMA-Registered Quality
The method of operation for quality certification is defined in the KEMA General Terms
And Conditions For Quality And Environmental Management Systems Certifications.
Integral publication of this certificate is allowed.
KEMA-Registered Quality, Inc.
4377 County Line Road
Chalfont, PA 18914
Ph: (215)997-4519
Fax: (215)997-3809
CRT 001 073004
ccredited By:
ANAB
A
Jupiter
CONTROL SYSTEM
AccuSwitch Soft Panels and Visual Status Display
Instruction Manual
SOFTWARE VERSION 1.0.0
86301680
MARCH 2009
Contacting Grass Valley
International
Support Centers
Local Support
Centers
(available
during normal
business hours)
France
24 x 7
Australia and New Zealand: +61 1300 721 495Central/South America: +55 11 5509 3443
Middle East: +971 4 299 64 40 Near East and Africa: +800 8080 2020 or +33 1 48 25 20 20
Europe
+800 8080 2020 or +33 1 48 25 20 20
+800 8080 2020 or +33 1 48 25 20 20
Hong Kong, Taiwan, Korea, Macau: +852 2531 3058 Indian Subcontinent: +91 22 24933476
PC IP: "192.168.1.101"
Multi-Level Device ID: “02”
Gateway: "192.168.1.1"
Multi-Level XY GUI PC
PC IP: “192.168.253.30”
Multi-Level XY GUI Device ID: "01"
Crosspoint
Bus
GV matrix router
Remote
Basic XY GUI PC
8536_28
Overview
The Jupiter Basic XY and Multi-Level XY Soft Panels are applications that
are used to control a matrix router. These Soft Panel applications run on the
English version of the Windows XP operating systems. The computers that
are running these Soft Panel applications must be able to communicate,
through a network, with a Jupiter CM-4000 System Controller running
AccuSwitch (See
64 devices, which can include any combination of hardware and soft
panels.
NoteThe number of entries in the Control Panel’s Input, Output, Level, Sequence
and Override sets will have an effect on the System Controller’s memory.
Figure 1). Each AccuSwitch Control board supports up to
Section 1
Figure 1. Jupiter System with Basic XY and Multi-level XY Soft Panels
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual1
Section 1 — Soft Panel Introduction
Ordering Information
Table 1. Soft Panel Series Ordering Information
JUP-Soft Panel Series Software Control Panels
JUP-SP-Basic XYBasic XY soft panels featuring source to destination routing
Hard DiskUp to 500 MB of available space may be required.
Installation DriveThe .NET Framework 3.5 default installation location is the PC’s system drive (the
drive that boots your system). Ensure at least 500 MB is available on the system drive.
Installing the Soft Panel Application
The following instructions show the steps that are needed to install both
soft Panel applications. The Basic XY Soft Panel screens are used as exam
ples. However, the Multi-Level XY instructions steps are identical to the
Basic XY instructions.
To start the Soft Panel application installation process:
Software Installation
-
1. Insert the supplied software CDROM into the computer’s CD Drive
and follow the prompts.
NoteThe CD should automatically start the installation process. If not, browse to
the CD, using Window Explorer, and then click the setup.exe icon.
2. If this is an Initial installation, you may see a message asking if you
want to install Microsoft .NET Framework. If so, select
Yes. (The 3.5 SP1
version of .NET is located on the CD.)
Depending on the version of the computer’s OS, the system may reboot
automatically during this process.
NoteAfter an auto reboot, it may take several minutes for the system to display the
Soft Panel installation welcome screen.
The Soft Panel Welcome screen will then appear (Figure 2).
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual3
Section 1 — Soft Panel Introduction
Figure 2. Soft Panel Installer Welcome Screen
3. Click the Next> button to begin the installation process. The License
4. Click the I accept the terms in the License agreement radio button.
5. Click the Next> button to begin the installation process.
6. Follow the instructions on the following installation screens, click the
Next button as needed(Figure 4).
4Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual
Figure 4. Soft Panel Installation Screens
Software Installation
7. The InstallShield Wizard Completed screen will then appear when the
installation process is finished (Figure 5).
Figure 5. Installation Completed Screen
8. Click the Finish button. The Installation application will then close.
Soft Panel Desktop Icon
As part of the installation process a Soft Panel shortcut, for the type of soft
panel that was installed (Basic XY or Multi-Level XY), will be displayed on
your PC’s desktop (
installed soft panel. The Soft panel must be configured to meet your needs
NoteSee the Configuration section below for the configuration steps.
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual5
Figure 6). Clicking this shortcut will launch the
Section 1 — Soft Panel Introduction
Figure 6. The Soft Panels Shortcut Example
NoteThe Soft Panel application still needs to be configured with your Jupiter
Performing Maintenance on the Soft Panel Application
When a Soft Panel application already exists on the PC when the installa-
tion program is run:
•If the version is older than what is being installed, then the installa-
•If the version is the same as what is being installed, then the
AccuSwitch system before it will become operational.
tion wizard will ask to perform an update.
Welcome screen displays a Modify, Repair, Remove message.
Next> button allows you to make changes to the Soft Panel
Select the desired task and then click the Next> button.
6Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual
Configuration
Soft Panel PC IP Settings
Soft Panel Application Settings
Configuration
The PC, on which the Soft Panel application is installed, must be configured
to communicate with the Jupiter AccuSwitch Controller. Consult with your
Network administrator for this information.
During the following steps, you will need to know the IP address of the
primary AccuSwitch Controller (and the secondary, if it is installed) that
will be associated with the Soft Panel and the PC’s IP address. Use the
Jupiter File Server JNS Control Center application’s Board Info tab to deter
mine the AccuSwitch Controller IP address (the Control Center application
is described in the Jupiter CM-4000 Installation and Operating manual).
-
NoteConsult with your Network administrator if you do not know the network
values to enter.
1. Launch the Soft Panel application. This will display the main Soft Panel
screen (Figure 8).
Figure 8. Basic XY Soft Panel Startup Display Example
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual7
Section 1 — Soft Panel Introduction
2. Select Route Connection from the File menu (File > Route Connection).
The Router Connection Editor dialog will then appear.
3. Enter the name for the setting in the Setting Name field. The Setting
Name field can be changed when configuring a new connection, before
the
4. Select the Protocol from the list.
NoteCurrently, the only selectable option for the Protocol list is ES-LAN.
Figure 9. Router Connection Editor Dialog
Save button has been selected.
5. Enter the IP address of the AccuSwitch Controller that is associated
with this Soft Panel in the Primary IP Address field.
6. Enter the IP address of the secondary AccuSwitch Controller in the
Secondary IP Address field. If there is not a secondary controller, then
leave the field blank.
7. Enter a number between 1 and 64 for the Device ID field. This number
must be unique from all panels that are associated with the same
AccuSwitch Controller. The Device ID is also entered on the MPK
Devices table, as described below in the MPK Table Entries section.
NoteThe Device ID number selected here corresponds to the MPK table Address
entry that uses two digit leading-zero numbers (01-09).
8Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual
8. Select the IP address for the PCs NIC card from the PC IP Address drop-
The Save
button
down list, if it is not already selected (See Soft Panel PC IP Settings on
page 7).
NoteIf you have more than one NIC card, consult your IT department to determine
which IP Address will be able to communicate with the Jupiter Network
(AccuSwitch control board).
9. Click the Connect button.
Saving the Device Settings
Save the settings by selecting Save Settings from the File menu (File > Save
Settings). The Save Device Settings dialog will then appear.
To save the device settings:
1. Create a name for the settings file. For example, the Panel Name “ES-
LAN2” could be used.
2. Click the Save button (Figure 10).
Configuration
Figure 10. The Save Button
The current connection settings are then saved to the "NetworkSettings.xml" file, which is located in the installation directory for the specific
control panel. For example, C:\Program Files\Thomson\Jupiter Basic XY,
would be the location for the settings for the Basic XY panel.
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual9
Section 1 — Soft Panel Introduction
Assigning a Function Key
The Multi-Level XY Soft panel application allows you to assign a Function
key for the
Ta ke s.
To Assign a function key:
1. Go to Assign Function Key.... from the Settings menu (Settings > Assign
Function Key....). The Assign Function Key dialog will then appear.
Figure 11. Assign Function Key Dialog
Take button. The function key could then be used to perform
2. Select a Function key from the drop-down list. Any function key
between F1 and F12 can be assigned.
3. Click OK to save the selection.
Setting Password Protection
If desired, a password can be used to protect the settings file, see Figure 12.
This setting is optional.
To set password protection:
1. Select Change/Set Password from the Settings menu (Settings >
Change/Set Password..).
Figure 12. Password Dialog
10Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual
View Menu
Configuration
2. Enter a password from 1 to 20 characters. Passwords are case-sensitive.
Any characters can be used, including spaces.
Once a password has been set, you will need to log in before you can
change Soft Panel settings, see
Figure 13. Login Dialog, if Password Protected
Currently the only available selection in the View menu is Options.
Figure 13.
Options
The Soft Panel’s background colors, font’s colors, styles, and size can be
changed to meet your needs. The Soft Panel application’s default colors are
listed below in the
1. Select View > Options... from the Menu bar. The Options screen will
then appear (Figure 14).
Figure 14. Options Screen
Default Colors section.
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual11
Section 1 — Soft Panel Introduction
2. Clicking any one of the Option buttons, that start with “Pick. . .,”will
open the Color dialog(Figure 15).
Figure 15. Options Color Selection Dialog
3. Selecting a color and then clicking the OK button, in the Color dialog will
change the option’s example display field to that color.
4. Controls are also available that allow selecting the font size, bold, and
italic attributes (see Figure 14 on page 11).
Default Colors
The colors listed below are the default color settings.
Table 3. Default Colors
ColorFunction
GreenCurrent Source/Status
MagentaProtect
RedLock
YellowDestination
CyanPreset/Next source
AmberMisc selections.
NoteIf a level on the Multi-Level XY is different from the first level, it will be dis-
played in Amber while on the Preset line, however, it will be displayed in
Green once on the Status line.
12Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual
Jupiter File Server Settings
The following overview assumes that the reader is familiar with the Jupiter
Facility Control System. If not, please refer to the Jupiter CM-4000 Installation and Operating manual.
MPK Table Entries
Although the Soft Panel and VSD applications are not actually an MPKtype panel (it does not use the Message Per Keystroke protocol), the MPK
table is used for configuration purposes.
MPK Device - This column is used to create a name, up to eight characters in
length, for each Soft Panel. This name must be unique system-wide.
Type - Select type “CP-ESLAN” on the pull-down menu. Select
“CPESXTND” for use with 98 categories.
Expansion - Not used for Soft Panels (leave unchecked).
Password - Not used for Soft Panels.
Jupiter File Server Settings
-
Board - Name of AccuSwitch Controller associated with this Soft Panel. The
source of this name is the Network Description table.
Port - Not used for Soft Panels.
Address - Panel address from 01 to 64. Must be unique for panels associated
with the same AccuSwitch Controller. This number is referred to as the
“Device ID” on the Soft Panel “Devices > Settings” menu.
Input Set - Name of CP Input Set to be assigned to this panel. The usual prac-
tice is to have one CP Input Set, containing the names of all sources, be
applied to all panels. However, special CP Input Sets could be created
which list only selected sources. Such a set could be used to prevent certain
panels from selecting specific sources.
In Panel - This column is not used for Soft Panels.
Out Set - Name of the CP Output Set to be assigned to this panel. If the entry
is an actual CP Output Set, then the control panel will be able to control all
the destinations listed in that Set. Depending on the contents of the set, this
would allow for full-matrix or multi-bus control. The source of the destina
tion name is the Switcher Output table.
Out Panel - This column is not used for Soft Panels.
Level Set - Select the CP Level Set name.
-
Override - Not used for Soft Panels.
Sequence - A Sequence Set can be created and named, which, when assigned
to a panel, makes the sequences in that set available on that panel.
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual13
Section 1 — Soft Panel Introduction
Control Panel Sets
The router sources and destinations for the Soft Panels are specified by cre-
ating a CP Input/Output sets of type of CPESXTND for device type
CPESXTND, or CP-3800 for the device type CP-ESLAN. Soft panels use
level and sequence sets of type CP-3800.
These sets are assigned to each panel using the MPK Devices table.
The CP Input and Output sets are also the source of the eight-character
mnemonics displayed on the panel.
VSD Control panel sets must contain all Sources, Destinations, and Levels
to display the status correctly.
Compiling
Before the panel can be used, the edited Jupiter set must be compiled and
the appropriate configuration set made active using the Control Center. For
more information, please refer to “Configurator” in the Jupiter CM-4000
Installation and Operating manual.
14Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual
Basic XY Soft Panel
Basic XY Soft Panel Screen Description
Clicking the Jupiter Basic XY desktop icon (or running the BasicXYPanel.exe file) will open the Basic XY Soft Panel screen see Figure 16. The
Destinations and Sources will be displayed on the buttons once the panel
has been configured.
Figure 16. The Basic XY Application
Section 2
The Menu Bar
The Menu Bar contains different menus for the application. This Menu bar
follows Windows standards, with some additional application specific
functions.
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual15
Section 2 — Basic XY Soft Panel
File Menu
Router Connection: Opens the Router Connection Settings window. This
window is where the Setting Name, Device ID, and the IP address of the
server that the Soft Panel will connect to.
Router Disconnect: Disconnects Soft Panel from the server.
Router Reconnect: Reconnects to the server using the most recent settings
Exit: Closes the Soft Panel application.
Settings Menu
Change/Set Password: Opens the Password window. See the Setting Pass-
word Protection section for more information
View Menu
Options: Opens the Options window. See the Options section for more
information.
Help Menu
The Help menu currently has the About Jupiter Basic XY option. An About
box will appear when this option is selected. The About box has the fol
lowing information: Copyright information, the name of the application,
and the current version number of application.
Figure 17. The About Box
Click the OK button to close the About box.
Display Fields and Buttons
The Basic XY Soft Panel Screen’s display fields and buttons definitions are
provided below, in clockwise order.
-
Source Categories - Displays the matrix router source categories that can be
selected by this Soft Panel.
Source Entries - Displays the specific matrix router sources that can be
selected by this Soft Panel.
16Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual
Basic XY Soft Panel Operating Procedures
Destination Categories - Displays the matrix router destination categories that
can be controlled by this Soft Panel.
Destination Entries - Displays the specific matrix router destinations that can
be controlled by this Soft Panel.
Destination - Displays the destination that is presently being controlled by
the panel.
Status - Displays the source presently switched to the panel's controlled des-
tination (shown for the first router level listed in the Jupiter CP Level Set or
CP Output Level Set--usually video).
Preset - Displays a preview of the names of the new sources after they are
selected.
Take button - Switches the Preset source to the indicated Destination.
Basic XY Soft Panel Operating Procedures
Making a Destination Selection / Status Check
To select a destination prior to making a switch or to check status:
1. Select a new destination category(Figure 18). This selection will
populate the Destination Entries fields with the available destinations
in the selected category.
Figure 18. Destination Category Section
2. Choose a destination entry(Figure 19). The name of the destination will
be shown in the Destination window (shown above the “entry” button)
and the name of the source that is currently switched to this destination,
will be shown in the Status window.
Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual17
Section 2 — Basic XY Soft Panel
Figure 19. Destination Entries Section
NotePanels will show eight asterisks (****) as a status, when the panel has no
NoteWhen a panel cannot be changed to the desired output, the panel may have
way of reporting the mnemonic of the source. This condition can happen
when a source selected by panel “B” has the same destination being statused
by Panel “A”, and this source not available in the configuration for panel “A”.
been limited to certain outputs by the CP Output set used on the Jupiter MPK
Devices table.
Source and Destination Paging Buttons
The Paging buttons are used to scroll through and to see the destinations and
the source panel’s options. Sometimes, all of these destination and source
options cannot fit on the screen. The “paging” buttons will be active if there
are options “off screen”, if not, they will be grayed out. Table 1,
Buttons shown below, will provide the names and a description of what the
button will do when it is clicked.
Table 4. The Paging Buttons
The Start button: Clicking this button will
show the beginning options on the “list.”
The Previous button: Clicking this button
will show the preceding options.
The Next button: Clicking this button will
show the succeeding options.
The End button: Clicking this button will
show the last options on the “list.”
The Paging
18Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual
Loading...
+ 60 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.