Graco PD44, 313876M Maintenance Manual

Operation - Maintenance
PD44
Metering Valves and Feed Systems
Meter, mix, and dispense system for precise two-component micro-dispensing of sealants and adhesives. Not approved for use in European explosive atmosphere locations.
Important Safety Instructions
Read all warnings and instructions in this man­ual. Save these instructions.
313876M
EN
Linear Resistive Transducer PD44 Meter-
ing Valve shown, Feed Systems not shown
Contents
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Isocyanate Conditions . . . . . . . . . . . . . . . . . . . . . . 6
Material Self-ignition . . . . . . . . . . . . . . . . . . . . . . . 6
Moisture Sensitivity of Isocyanates . . . . . . . . . . . . 6
Keep Components A and B Separate . . . . . . . . . . 6
Foam Resins with 245 fa Blowing Agents . . . . . . . 6
Changing Materials . . . . . . . . . . . . . . . . . . . . . . . . . 6
Product Configurator . . . . . . . . . . . . . . . . . . . . . . . 7
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Component Identification . . . . . . . . . . . . . . . . . . . 13
Typical System Configurations . . . . . . . . . . . . . 13
Typical Feed System Components . . . . . . . . . 14
Micrometer PD44 Metering Valve . . . . . . . . . . . 15
LRT PD44 Metering Valve . . . . . . . . . . . . . . . . 16
Motor Driven PD44 Metering Valve . . . . . . . . . . 17
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Typical Installation . . . . . . . . . . . . . . . . . . . . . . 18
Tank Level Sensor Wiring Schematic . . . . . . . . 19
Valve Mounting Diagram . . . . . . . . . . . . . . . . . . 19
Motor Mounting Diagram . . . . . . . . . . . . . . . . . 20
Custom Drive Mounting Diagram . . . . . . . . . . . 20
Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Adjusting the Shot Size . . . . . . . . . . . . . . . . . . . . . 22
Micrometer PD44 Only . . . . . . . . . . . . . . . . . . . 22
LRT and Motor Driven PD44 . . . . . . . . . . . . . . . 22
Ratio Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Sequence of Operation . . . . . . . . . . . . . . . . . . . 24
Pressure Relief Procedure . . . . . . . . . . . . . . . . . . 25
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Rebuild . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Wetted Section Disassembly . . . . . . . . . . . . . . . 27
Wetted Section Reassembly . . . . . . . . . . . . . . . 29
Spool Valve Rebuild . . . . . . . . . . . . . . . . . . . . . 30
Wetted Section Rebuild . . . . . . . . . . . . . . . . . . . 31
Micrometer Drive Rebuild
(Micrometer PD44 Only) . . . . . . . . . . . . . . . 34
Electrical Requirements . . . . . . . . . . . . . . . . . . . . 36
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
California Proposition 65 . . . . . . . . . . . . . . . . . . 40
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 42
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 42
2 313876M

Related Manuals

Manuals are available at www.graco.com
Component manuals in U.S. English.
PD44 Manuals
Part Description
313877 PD44 Control Box Setup - Operation
3A0987 PD44 Parts
Feed System Manuals
306565 Air-Driven, Stainless Steel Agitators
307043
308116 Severe-Duty, UHMWPE/PTFE or PTFE
308167 Low Volume Air Regulators
308168 High Volume Air Regulators
308169 Air Filters, Lubricators and Kits
309306
312376 Stainless Steel Agitator Kit
313526
3A1452 20 oz Cartridge
Monark
Packed Stainless Steel Pumps
Air-Operated Husky™ Diaphragm Pumps
Check-Mate® Pump Packages
®
Air Motor
Related Manuals

Models

Max Outlet
Fluid Working
Metering Valve
Model
Linear Resistive
Transducer (LRT)
Micrometer
Motor Driven
* If a custom PD44 is ordered, it will not be CE
approved unless otherwise noted.
Pressure
psi (MPa, bar)
2000 (14, 138) 100 (0.7, 7) 1200 (8, 83) 400 (2.8, 28)
2000 (14, 138) 100 (0.7, 7) 1200 (8, 83) 400 (2.8, 28)
2000 (14, 138) 100 (0.7, 7) 1200 (8, 83) 400 (2.8, 28)
psi (MPa, bar)
Max Air
Working
Pressure
Max Inlet Working Pressure
psi (MPa, bar)
CE
Approved*Metal Sleeves Plastic Sleeves
313876M 3

Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama­tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
Do not point gun at anyone or at any part of the body.
Do not put your hand over the dispense outlet.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Follow Pressure Relief Procedure in this manual, when you stop dispensing and before cleaning, checking, or servicing equipment.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
Read MSDS’s to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
Always wear impervious gloves when spraying or cleaning equipment.
If this equipment is used with isocyanate material, see additional information on isocyanates in Iso­cyanate Conditions Section of this manual.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to:
Protective eyewear
Clothing and respirator as recommended by the fluid and solvent manufacturer
Gloves
Hearing protection
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).
Keep work area free of debris, including solvent, rags and gasoline.
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.
Ground all equipment in the work area. See Grounding instructions.
Use only grounded hoses.
If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
Keep a working fire extinguisher in the work area.
4 313876M
Warnings
WARNING
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause elec­tric shock.
Turn off and disconnect power cord before servicing equipment.
Use only grounded electrical outlets.
Use only 3-wire extension cords.
Ensure ground prongs are intact on power and extension cords.
Do not expose to rain. Store indoors.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
Do not leave the work area while equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure in this manual when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu­facturer’s replacement parts only.
Do not alter or modify equipment.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
PLASTIC PARTS CLEANING SOLVENT HAZARD
Use only compatible water-based solvents to clean plastic structural or pressure-containing parts. Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage. See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s warnings.
313876M 5

Isocyanate Conditions

Isocyanate Conditions
Spraying or dispensing materials containing isocya­nates creates potentially harmful mists, vapors, and atomized particulates.
Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates.
Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventila­tion in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area.
To prevent contact with isocyanates, appropriate per­sonal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.

Material Self-ignition

To prevent exposing ISO to moisture:
Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container.
Keep the ISO lube pump reservoir (if installed) filled with Graco Throat Seal Liquid (TSL™), Part 206994.
The lubricant creates a barrier between the ISO and the atmosphere.
Use moisture-proof hoses specifically designed for ISO, such as those supplied with your system.
Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use.
Never use solvent on one side if it has been con­taminated from the other side.
Always lubricate threaded parts with ISO pump oil or grease when reassembling.

Keep Components A and B Separate

Some materials may become self-igniting if applied too thickly. Read material manufacturer’s warnings and material MSDS.

Moisture Sensitivity of Isocyanates

Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts.
NOTE: The amount of film formation and rate of crystal­lization varies depending on the blend of ISO, the humidity, and the temperature.
NOTICE
To prevent cross-contamination of the equipment’s wetted parts, never interchange component A (isocy­anate) and component B (resin) parts.

Foam Resins with 245 fa Blowing Agents

Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.

Changing Materials

When changing materials, flush the equipment mul­tiple times to ensure it is thoroughly clean.
Always clean the fluid inlet strainers after flushing.
Check with your material manufacturer for chemical compatibility.
Most materials use ISO on the A side, but some use ISO on the B side.
Epoxies often have amines on the B (hardener) side. Polyureas often have amines on the B (resin) side.
6 313876M

Product Configurator

This system can be ordered with many different options as shown in the configurator below.
Product Configurator
PD44 C - A - BCD -EFG- H - I - J - K - L - M - NO - P - Q - RS - T - U - V - W - X
Configurator Series Level
Base Unit
High Volume Rod Material, Size
Low Volume Rod Material, Size
High Volume Spool
Low Volume Spool
Outlet Nose
Mixer
Controls
Power Cord
High Volume Feed
High Volume Feed Hose
High Volume Feed Options
Low Volume Feed
Low Volume Feed Hose
Low Volume Feed Options
Vacuum Pump(s)
Bench Stand
Seal Lubricant
The following table applies to the PD44 configurations and indicates all of the options available for each letter shown above.
Code A Part Base Unit
A 964000 Micrometer PD44 B 964001 Linear Resistive Transducer PD44 C 964002 Motor Driven PD44
Code B Part High Volume Rod Material
NOTE: See code CD for last two digits of part number
A 9641__ Hardened Steel B 9642__ Stainless Steel, UHMW C 9643__ Tungsten Carbide, UHMW
Code
CD
NOTE: See code B for first four digits of part number
01 ____01 1.25 mm rod diameter 02 ____02 1.38 mm rod diameter 03 ____03 1.50 mm rod diameter 04 ____04 1.63 mm rod diameter 05 ____05 1.75 mm rod diameter 06 ____06 2.00 mm rod diameter 07 ____07 2.13 mm rod diameter 08 ____08 2.25 mm rod diameter 09 ____09 2.38 mm rod diameter 10 ____10 2.50 mm rod diameter 11 ____11 2.63 mm rod diameter 12 ____12 2.75 mm rod diameter 13 ____13 3.00 mm rod diameter 14 ____14 3.13 mm rod diameter 15 ____15 3.25 mm rod diameter 16 ____16 3.38 mm rod diameter 17 ____17 3.50 mm rod diameter 18 ____18 3.63 mm rod diameter
Part High Volume Rod Size
19 ____19 3.75 mm rod diameter 20 ____20 4.00 mm rod diameter 21 ____21 4.25 mm rod diameter 22 ____22 4.50 mm rod diameter 23 ____23 4.63 mm rod diameter 24 ____24 4.75 mm rod diameter 25 ____25 4.88 mm rod diameter 26 ____26 5.00 mm rod diameter 27 ____27 5.13 mm rod diameter 28 ____28 5.25 mm rod diameter 29 ____29 5.50 mm rod diameter 30 ____30 5.75 mm rod diameter 31 ____31 6.00 mm rod diameter 32 ____32 6.13 mm rod diameter 33 ____33 6.25 mm rod diameter 34 ____34 6.38 mm rod diameter 35 ____35 6.50 mm rod diameter 36 ____36 6.63 mm rod diameter 37 ____37 6.75 mm rod diameter 38 ____38 7.00 mm rod diameter 39 ____39 7.25 mm rod diameter 40 ____40 7.50 mm rod diameter 41 ____41 7.63 mm rod diameter 42 ____42 7.75 mm rod diameter 43 ____43 7.88 mm rod diameter 44 ____44 8.00 mm rod diameter
313876M 7
Product Configurator
Code E Part Low Volume Rod Material
NOTE: See code FG for last two digits of part number
A 9641__ Hardened Steel B 9642__ Stainless Steel, UHMW
C 9643__ Tungsten Carbide, UHMW
Code FG Part Low Volume Rod Size
NOTE: See code E for first four digits of part number
01 ____01 1.25 mm rod diameter 02 ____02 1.38 mm rod diameter 03 ____03 1.50 mm rod diameter 04 ____04 1.63 mm rod diameter 05 ____05 1.75 mm rod diameter 06 ____06 2.00 mm rod diameter 07 ____07 2.13 mm rod diameter 08 ____08 2.25 mm rod diameter 09 ____09 2.38 mm rod diameter 10 ____10 2.50 mm rod diameter 11 ____11 2.63 mm rod diameter 12 ____12 2.75 mm rod diameter 13 ____13 3.00 mm rod diameter 14 ____14 3.13 mm rod diameter 15 ____15 3.25 mm rod diameter 16 ____16 3.38 mm rod diameter 17 ____17 3.50 mm rod diameter 18 ____18 3.63 mm rod diameter 19 ____19 3.75 mm rod diameter 20 ____20 4.00 mm rod diameter 21 ____21 4.25 mm rod diameter 22 ____22 4.50 mm rod diameter 23 ____23 4.63 mm rod diameter 24 ____24 4.75 mm rod diameter 25 ____25 4.88 mm rod diameter 26 ____26 5.00 mm rod diameter 27 ____27 5.13 mm rod diameter 28 ____28 5.25 mm rod diameter 29 ____29 5.50 mm rod diameter 30 ____30 5.75 mm rod diameter 31 ____31 6.00 mm rod diameter 32 ____32 6.13 mm rod diameter 33 ____33 6.25 mm rod diameter 34 ____34 6.38 mm rod diameter 35 ____35 6.50 mm rod diameter 36 ____36 6.63 mm rod diameter 37 ____37 6.75 mm rod diameter 38 ____38 7.00 mm rod diameter 39 ____39 7.25 mm rod diameter 40 ____40 7.50 mm rod diameter 41 ____41 7.63 mm rod diameter 42 ____42 7.75 mm rod diameter 43 ____43 7.88 mm rod diameter 44 ____44 8.00 mm rod diameter
Code H Part High Volume Spool
1 964003 High viscosity, HS 2 964004 High viscosity, Stainless Steel/UHMWPE 3 964005 High viscosity, TC/UHMWPE 4 964006 Low viscosity, Stainless Steel
Code I Part Low Volume Spool
1 964011 High viscosity, HS 2 964012 High viscosity, Stainless Steel/UHMWPE 3 964013 High viscosity, TC/UHMWPE 4 964014 Low viscosity, Stainless Steel
Code J Part Outlet Nose
1 964020 Luer lock, equal ports, no check valves 2 964021 Luer lock, equal ports, dual check valves 3 964022 Equal ports, 7/8-9, no check valves 4 964023 Large and small ports, 7/8-9, no check
valves
5 964024 Large and small ports, 7/8-9, single
check valve 6 964025 Dual small ports, 7/8-9, no check valves 7 964026 Dual small ports, 7/8-9 dual check valves
Code K Part Mixer
1 964027 1/8-24 Luer Lock inlet and outlet, 0.5 cc 2 964028 3/16-32 bell mouth inlet, luer lock outlet,
2.0 cc
3 964029 1/4-24 bell mouth inlet, luer lock outlet,
4.0 cc
4 964030 1/4-32 bell mouth inlet, luer lock outlet,
5.5 cc
5 964031 1/4-48 bell mouth inlet, luer lock outlet,
8.0 cc
6 964032 3/16-32 bell mouth inlet, tapered outlet,
1.5 cc
7 964033 1/4-24 bell mouth inlet, tapered outlet,
3.5 cc
8 964034 3/16-24 bell mouth inlet, tapered outlet,
1.0 cc
Code L Part Controls
1 964035 Pneumatic, micrometer, wire harness
only 6 964040 Pneumatic, linear resistive transducer,
wire harness only B 964045 Motor driven, I/O, wire harness only
D -- No Controls - use only with UniXact
motion table
E 25C687 No Controls with pressure transducer
block. Use only with UniXact motion table
8 313876M
Product Configurator
Code M Part Power Cord
1 121055 120 VAC, North American cord set 2 121054 250 VAC, 1 phase, no plug 3 121056 10 amp, 250 volt, continental Europe 4 121057 10 amp, 250 volt, United Kingdom and
Ireland 5 121058 10 amp, 250 volt, Israel 6 124864 10 amp, 250 volt, Australia 7 124861 10 amp, 250 volt, Italy 8 124863 10 amp, 250 volt, Switzerland 9 124862 10 amp, 250 volt, Denmark A 121060 10 amp, 250 volt, India N -- None
Code
NO
01 964050 02 964051 03 964052 04 964053
05 964054 06 964055
07 964056
08 964057
NN --
Code P Part High Volume Feed Hose
1 964082 1/2 in. x 8 ft PTFE and stainless steel
3 964084 1/2 in. x 10 ft PTFE and stainless steel
5 964086 1/2 in. x 15 ft PTFE and stainless steel
N -- None
Code Q Part High Volume Feed
C 964090 Low level sensor 11:1 Ram only N -- None
Part High Volume Feed
20 oz cartridge feed with mounting post
1 gallon pail Ram and transfer pump
5 gallon pail cover with diaphragm pump
5 gallon pail cover diaphragm pump and
agitator
5 gallon pail cover and 5:1 transfer pump
5 gallon pail cover, 1:1 pump with dip
tube for moisture sensitive materials
5 gallon single post Ram with 11:1 pump,
mild steel
5 gallon single post Ram with 11:1 pump,
stainless steel
None
hose, stainless steel fittings
hose, stainless steel fittings
hose, stainless steel fittings
Code RS Part Low Volume Feed
01 964050 02 964051 03 964052 04 964053
05 964054 06 964055
07 964056
08 964057
NN --
Code T Part Low Volume Feed Hose
1 964082 1/2 in. x 8 ft PTFE and stainless steel
3 964084 1/2 in. x 10 ft PTFE and stainless steel
5 964086 1/2 in. x 15 ft PTFE and stainless steel
7 -- None
Code U Part Low Volume Feed
C 964090 Low level sensor 11:1 Ram only N -- None
Code V Part Vacuum Pump(s)
N -- None
Code W Part Bench Stand
A 964095 Adjustable height bench stand N -- None
Code X Part Seal Lubricant
T 206994 Fluid, TSL, 8 ounce bottle
20 oz cartridge feed with mounting post 1 gallon pail Ram and transfer pump 5 gallon pail cover with diaphragm pump 5 gallon pail cover diaphragm pump and
agitator 5 gallon pail cover and 5:1 transfer pump 5 gallon pail cover, 1:1 pump with dip
tube for moisture sensitive materials 5 gallon single post Ram with 11:1 pump,
mild steel 5 gallon single post Ram with 11:1 pump,
stainless steel None
hose, stainless steel fittings
hose, stainless steel fittings
hose, stainless steel fittings
313876M 9

Accessories

Accessories
Mixer Kits with Shroud
Part Description
964034 Mixer, Kit, 3/16 in. (4.8mm) x 24, 10
taper tip mixers with shroud
964032 Mixer, Kit, 3/16 in. (4.8mm) x 32, 10
taper tip mixers with shroud
964028 Mixer, Kit, 3/16 in. (4.8mm) x 32, 10
Luer Lock tip mixers with shroud/sleeve
964033 Mixer, Kit, 1/4 in. (6.5mm) x 24, 10
taper tip mixers with shroud
964029 Mixer, Kit, 1/4 in. (6.5mm) x 24, 10 Luer
Lock tip mixers with shroud/sleeve
964030 Mixer, Kit, 1/4 in. (6.5mm) x 32, 10 Luer
Lock tip mixers with shroud/sleeve
964031 Mixer, Kit, 1/4 in. (6.5mm) x 48, 10 Luer
Lock tip mixers with shroud/sleeve
Mixer Packs
Part Description
964027 Mixer, 1/8 in. (3.2mm) x 24 Luer Lock
inlet/tip, 10 Pack
16D962 Mixer, 1/8 in. (3.2mm) x 24 Luer Lock
inlet/tip, 50 Pack
16D963 Mixer, 1/8 in. (3.2mm) x 24 Luer Lock
inlet/tip, 250 Pack
16D978 Mixer, 3/16 in. (4.8mm) x 24 taper tip,
50 Pack
16D979 Mixer, 3/16 in. (4.8mm) x 24 taper tip,
250 Pack
LC0077 Mixer, 3/16 in. (4.8mm) x 32 taper tip,
50 Pack
LC0084 Mixer, 3/16 in. (4.8mm) x 32 taper tip,
250 Pack
LC0082 Mixer, 3/16 in. (4.8mm) x 32 Luer Lock
tip, 50 Pack
LC0089 Mixer, 3/16 in. (4.8mm) x 32 Luer Lock
tip, 250 Pack
LC0078 Mixer, 1/4 in. (6.5mm) x 24 taper tip
mixer, 50 Pack
LC0085 Mixer, 1/4 in. (6.5mm) x 24 taper tip
mixer, 250 Pack
LC0083 Mixer, 1/4 in. (6.5mm) x 24 Luer Lock
tip, 50 Pack
Part Description
LC0090 Mixer, 1/4 in. (6.5mm) x 24 Luer Lock
tip, 250 Pack
16D968 Mixer, 1/4 in. (6.5mm) x 32 Luer Lock
tip, 50 Pack
16D969 Mixer, 1/4 in. (6.5mm) x 32 Luer Lock
tip, 250 Pack
16D970 Mixer, 1/4 in. (6.5mm) x 48 Luer Lock
tip, 50 Pack
16D973 Mixer, 1/4 in. (6.5mm) x 48 Luer Lock
tip, 250 Pack
10 313876M
O-Rings and Seals
Accessories
Part Description
24E247 Kit, O-ring, chemical resistant, PD44
24E248 Kit, Seal, Spool, H.V., PD44
24E249 Kit, Seal, Spool, L.V., PD44
16B265 Seal, Posipack, 1.25, ZAP
16B266 Seal, Posipack, 1.38, ZAP
16B267 Seal, Posipack, 1.50, ZAP
16B268 Seal, Posipack, 1.63, ZAP
16B269 Seal, Posipack, 1.75, ZAP
16B270 Seal, Posipack, 2.00, ZAP
16B271 Seal, Posipack, 2.13, ZAP
16B272 Seal, Posipack, 2.25, ZAP
16B273 Seal, Posipack, 2.38, ZAP
16B274 Seal, Posipack, 2.50, ZAP
16B275 Seal, Posipack, 2.63, ZAP
16B276 Seal, Posipack, 2.75, ZAP
16B277 Seal, Posipack, 3.00, ZAP
16B278 Seal, Posipack, 3.13, ZAP
16B279 Seal, Posipack, 3.25, ZAP
16B280 Seal, Posipack, 3.38, ZAP
16B281 Seal, Posipack, 3.50, ZAP
16B282 Seal, Posipack, 3.63, ZAP
16B283 Seal, Posipack, 3.75, ZAP
16B284 Seal, Posipack, 4.00, ZAP
16B285 Seal, Posipack, 4.25, ZAP
Part Description
16B286 Seal, Posipack, 4.50, ZAP
16B287 Seal, Posipack, 4.63, ZAP
16B288 Seal, Posipack, 4.75, ZAP
16B289 Seal, Posipack, 4.88, ZAP
16B290 Seal, Posipack, 5.00, ZAP
16B291 Seal, Posipack, 5.13, ZAP
16B292 Seal, Posipack, 5.25, ZAP
16B293 Seal, Posipack, 5.50, ZAP
16B294 Seal, Posipack, 5.75, ZAP
16B295 Seal, Posipack, 6.00, ZAP
16B296 Seal, Posipack, 6.13, ZAP
16B297 Seal, Posipack, 6.25, ZAP
16B298 Seal, Posipack, 6.38, ZAP
16B299 Seal, Posipack, 6.50, ZAP
16B300 Seal, Posipack, 6.63, ZAP
16B301 Seal, Posipack, 6.75, ZAP
16B302 Seal, Posipack, 7.00, ZAP
16B303 Seal, Posipack, 7.25, ZAP
16B304 Seal, Posipack, 7.50, ZAP
16B305 Seal, Posipack, 7.63, ZAP
16B306 Seal, Posipack, 7.75, ZAP
16B307 Seal, Posipack, 7.88, ZAP
16B450 Seal, Posipack, 8.00, ZAP
Needles
Part Description
E4000025-50 Needle, Luer Lock, Sampler Package
(10 each 14 ga x 1/2 in., 16 ga x 1/2 in., 18 ga x 1/2 in., 20 ga x 1/2 in., 22 ga x 1/2 in.)
E4000001-50 Needle, Luer Lock, 14 Gauge x 1/2 in.,
50 Pack
E4000004-50 Needle, Luer Lock, 15 Gauge x 1/2 in.,
50 Pack
E4000005-50 Needle, Luer Lock, 16 Gauge x 1 in.,
50 Pack
313876M 11
Part Description
E4000006-50 Needle, Luer Lock, 18 Gauge x 1 in.,
50 Pack
E4000011-50 Needle, Luer Lock, 22 Gauge x 1/2 in.,
50 Pack
E4000014-50 Needle, Luer Lock, 14 Gauge x 1 in.,
50 Pack
E4000024-50 Needle, Luer Lock, 23 Gauge x 1/2 in.,
50 Pack
E4000088-50 Needle, Luer Lock, 16 Gauge x 1/2 in.,
50 Pack
Grounding

Grounding

This product must be grounded. In the event of an elec­trical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric cur­rent.
Metering valve: attach ground wire from grounding lug to true earth ground. See Component Identification starting on page 13.
Fluid hoses: use only electrically conductive hoses.
Feed system components: attach ground wire from
grounding lug to true earth ground. See feed system manual for grounding points. See Related Manuals on page 3.
Fluid supply container: follow local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive sur­face, such as paper or cardboard, which interrupts grounding continuity.

Overview

This plural component meter, mix, and dispense device accurately meters liquid and semi-paste materials.
The machine is ideal for a two-component application requiring very small and precisely mixed shots.
The ratio of the pneumatic cylinder area to pump shaft area provides the adjustable pressure intensification needed to move the separate liquids through the mixer with a flow rate suitable for production requirements.
The complete system is enclosed. Mixing of the two materials takes place only in the mixer at the final stage of metering valve operation. See Sequence of Opera- tion on page 24.
12 313876M

Component Identification

Typical System Configurations

Base Unit
Component Identification
A Side Feed
A Side Feed
1
Liquid Control Corp.
8400 PORT JACKSON AVE. N.W. NORTH CANTON, OH 44720 USA
SERIAL NUMBER
10 56 9078234
MODEL NUMBER
B Side Feed
WARNING
Do Not service without removing air pressure and waring saftey glasses.
Controls
PUSH TO
LOCK PULL TO RELEASE
B Side Feed
Base Unit
Controls
CONTROL POWER
Liquid Control Corp.
8400 PORT JACKSON AVE. N.W. NORTH CANTON, OH 44720 USA
MODEL
SERIAL
NUMBER
NUMBER
FIG. 1
313876M 13