Graco Mini Fire-Ball Instruction Manual

Instructions - Parts List
Model 253388 shown
Mini Fire-Ball® 225, 50:1 Grease Pump Packages
Portable units for dispensing heavy grease.
See page 2 for model numbers.
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
309967F
EN

Models

Models
Model No. Size
246910 35-50 lb
(16-23 kg)
253384† 35-50 lb
(16-23 kg)
253362 35-50 lb
(16-23 kg)
246911 35-50 lb
(16-23 kg)
253385† 35-50 lb
(16-23 kg)
246913 35-50 lb
(16-23 kg)
253386† 35-50 lb
(16-23 kg)
246914 120 lb
(55 kg)
253387† 120 lb
(55 kg)
25C689 120 lb
(55 kg)
246915 120 lb
(55 kg)
253388† 120 lb
55 kg)
246916 120 lb
(55 kg)
253389† 120 lb
(55 kg)
246917 400 lb
(180 kg)
253390† 400 lb
(180 kg)
Dispense Kit
236058
Hose/Fitting
Kit 222072
Follow
Base Type Cover
222059 24F901
222059 220653
222059 24F901
24R350
204574
2-wheel
truck
2-wheel
truck
portable 24R350 24F902
portable 204574 220654
2-wheel
truck
2-wheel
truck
24R350
204574
24R350 24F902
204574 220654
24R350 24F902
24R350 24F902
204574 220654
200326 24F903
200326 223845
Plate
CE Kit
Handle Pail





240979
† These models are CE certified.
2 309967F

Warnings

Warnings
The following general warnings are for the setup, use, grounding, maintenance, and repair of this equipment. Addi­tional, more specific warnings may be found throughout the body of this manual where applicable. Symbols appear-
ing in the body of the manual refer to these general warnings. When these symbols appear throughout the manual, refer back to these pages for a description of the specific hazard.
WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your Graco distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
SKIN INJECTION HAZARD
High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
• Do not point dispense valve at anyone or at any part of the body.
• Do not put your hand over the end of the dispense nozzle.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Follow Pressure Relief Procedure in this manual, when you stop dispensing and before cleaning, checking, or servicing equipment.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
• Keep clear of moving parts.
• Do not operate equipment with protective guards or covers removed.
• Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
309967F 3

Operation/Service

FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources, such as cigarettes and portable electric lamps.
• Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
• Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
• Ground all equipment in the work area.
• Use only grounded hoses.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
WARNING
• Read SDS’s to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to:
• Protective eyewear
• Clothing and respirator as recommended by the fluid and solvent manufacturer
• Gloves
• Hearing protection
Operation/Service
Refer to pump manual 309966 (supplied) for operating and service instructions.
4 309967F

Installation

Z
Y
ti1052
Installation

General Information

NOTE: Reference numbers and letters in parenthe-
ses in the text refer to the callouts in the figures and parts drawing.
NOTE: Always use genuine Graco parts and accessories, available from your Graco distributor.
Air Line Accessories
See page 6 for recommended air accessories and installation.

Grounding

Air compressor: follow manufacturer’s recommenda-
tions.
Dispense valve: ground through connection to a prop­erly grounded fluid hose and pump.
Fluid supply container: follow local code.
To maintain grounding continuity when flushing or relieving pressure: hold metal part of the dispense
valve firmly to the side of a grounded metal pail, then trigger the valve.
To reduce the risk of static sparking, ground the pump and all other components used or located in the dispensing area. Check your local electrical code for detailed instructions for your area and type of equipment.
Ground this equipment:
Pump: remove the ground screw (Z) and insert through
the eye of the ring terminal at end of ground wire (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See F
ground wire and clamp, order Part No. 222011.
IG. 1. To order a
FIG. 1
Air and fluid hoses: use only grounded hoses.
309967F 5
Installation
Key:
A Fluid dispense line B Pump ground wire (required) C Air regulator D Main air supply line EAir filter F Pump lubricator G Pump runaway valve H Bleed-type master air valve (required) J Quick-disconnect couple and nipple K Air regulator (9b) with safety valve (9c) and gauge (not shown)
Included with models 253384 through 253390
A
C
D
F
G
H
J
E
01519
B
Typical Installation
The installation shown below is only a guide for selecting and installing system components and accessories. Con­tact your Graco distributor for assistance in designing a system to suit your particular needs.

Air Line and Accessories

NOTE: Install air line accessories in the order
shown in the Typical Installation illustration.
Install a pump runaway valve (G) to shut off the air to the pump if the pump accelerates beyond the pre­adjusted setting. A pump that runs too fast can be seriously damaged.
Install an air line lubricator (F) for automatic air motor lubrication.
Install a bleed-type master air valve (H) to relieve air trapped between the valve and the motor when the valve is closed.
6 309967F
Trapped air can cause the air motor to cycle unexpectedly, causing serious injury if you are adjusting or repairing the pump. Be sure to follow the Pressure Relief Procedure on page 11.
Install the air regulator (C) to control pump speed and pressure.
On the main air supply line from the compressor, install an air line filter (E) to remove harmful dirt and contaminants fro the compressed air supply.
For models 253384 through 253390, install the pro­vided air regulator/safety valve (K) at the pump air inlet with the nipple (9a, also included).
Avoid hanging air accessories directly on the pump air inlet. The fittings are not strong enough to sup­port the accessories and may cause one or more to break. If accessories must be installed directly on the pump, provide a bracket on which to mount them.