US Patent 6,752,067
European Patent 1 208 287
Korean Patent 10-0668583
- For portable spray applications of architectural paints and coatings -
(Specifications, page 2.)
IMPORTANT SAFETY INSTRUCTIONS.
Read all warnings and instructions in this
manual. Save these instructions. See page
2 for model and series information including
dispense rate, recommended hose length,
guns, and maximum working pressure.
LTS 15 & LTS 17 Models ONLY: Use
water-based or mineral spirit-type materials
only. Do not use materials having flash points
lower than 70° F (21° C). For more information
MAGNUM LT S 15
Model: 257060
about your material, request MSDS from distributor or retailer.
AGNUMLTS.Graco.com
313034A
Related Manual:
313036 - Repair
ti11304a
M
AGNUM LTS 1 7
Model: 257065
ti11305a
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2007, Graco Inc. is registered to I.S. EN ISO 9001
MAGNUM ProLTS 17
Model: 257070
ti9369a
AGNUM ProLTS 19
M
Model: 257080
ti9368a
Specifications
Specifications
This equipment is not intended for use with flammable or combustible materials used in places such as
cabinet shops or other “factory”, or fixed locations. If you intend to use this equipment in this type of application, you must comply with NFPA 33 and OSHA requirements for the use of flammable and combustible
materials.
Model NameSeries
M
AGNUM
LTS 1 5
M
AGNUM
LTS 1 7
AGNUM
M
ProLTS 17
M
AGNUM
ProLTS 19
A
A
A
A
Dispense
Rate gpm
(lpm)
0.24 gpm
(0.91 lpm)
0.31 gpm
(1.17 lpm)
0.34 gpm
(1.29 lpm)
0.38 gpm
(1.44 lpm)
Hose Length and
Diameter
1/4 in. x 25 ft
(6.4 mm x 7.5 m)
1/4 in. x 25 ft
(6.4 mm x 7.5 m)
1/4 in. X 50 ft
(6.4 mm x 15 m)
1/4 in. X 50 ft
(6.4 mm x 15 m)
Getting Started
Fold-n-Store™ Cart (ProLTS Sprayers Only)
1. Unfold handle (a) and
align as shown.
2. Tighten wingnuts (b).
a
4. Install hose rack (d) to frame
Gun
Model
SG2280019193
SG2300021207
SG3 300021207
SG3300021207
handle. Install lock nuts.
Tighten securely.
Maximum Working
Pressure
PSIMPabar
d
ti9675a
b
3. Grasp cart handle
securely with one hand.
ti9369a
With the other hand lift
and pull Fold-n-Store
handle (a) located in
front of sprayer frame,
™
5. Secure power cord in
clip (e) located beneath
storage compartment.
toward you. Lift up front
of sprayer until you hear
a click and the cart is
locked in place.
2313034A
c
ti9679a
e
ti9719a
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back to these warnings. Additional, product-specific warnings may be found throughout
the body of this manual where applicable.
Grounding Instructions
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This product is equipped with a cord
having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that
is properly installed and grounded in accordance with all local codes and ordinances.
WARNING
GROUNDING
•Improper installation of the grounding plug is able to result in a risk of electric shock.
•When repair or replacement of the cord or plug is required, do not connect the grounding wire
to either flat blade terminal.
•The wire with insulation having an outer surface that is green with or without yellow stripes is
the grounding wire.
•Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.
•Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by
a qualified electrician.
•This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug
illustrated in the figure below.
ti9164a
•Only connect the product to an outlet having the same configuration as the plug.
•Do not use an adapter with this product.
Extension Cords:
•Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle
that accepts the plug on the product.
•Make sure your extension cord is not damaged. If an extension cord is necessary, use 12
AWG
(2.5 mm
2
) minimum to carry the current that the product draws.
An undersized cord results in a drop in line voltage and loss of power and overheating.
313034A3
Warnings
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help
prevent fire and explosion:
•Do not spray flammable or combustible materials near an open flame or sources of ignition
such as cigarettes, motors, and electrical equipment. For LTS 15 and LTS 17 models: only
use water-based or mineral spirit-type materials with a flash point greater than 70
° F (21° C).
•Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of
the spray system, including the pump, hose assembly, spray gun, and objects in and around
the spray area shall be properly grounded to protect against static discharge and sparks. Use
Graco conductive or grounded high-pressure airless paint sprayer hoses.
•Verify that all containers and collection systems are grounded to prevent static discharge.
•Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2
adapter.
•Do not use a paint or a solvent containing halogenated hydrocarbons.
•Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.
Keep pump assembly in a well ventilated area. Do not spray pump assembly.
•Do not smoke in the spray area.
•Do not operate light switches, engines, or similar spark producing products in the spray area.
•Keep area clean and free of paint or solvent containers, rags, and other flammable materials.
•Know the contents of the paints and solvents being sprayed. Read all Material Safety Data
Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint
and solvents manufacturer’s safety instructions.
•Fire extinguisher equipment shall be present and working.
•Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing
or cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors.
SKIN INJECTION HAZARD
•Do not aim the gun at, or spray any person or animal.
•Keep hands and other body parts away from the discharge. For example, do not try to stop
leaks with any part of the body.
•Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.
•Use Graco nozzle tips.
•Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs
while spraying, follow the Pressure Relief Procedure for turning off the unit and relieving the
pressure before removing the nozzle tip to clean.
•Do not leave the unit energized or under pressure while unattended. When the unit is not in
use, turn off the unit and follow the Pressure Relief Procedure for turning off the unit.
•High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the
event that injection occurs, get immediate surgical treatment.
•Check hoses and parts for signs of damage. Replace any damaged hoses or parts.
•This system is capable of producing 3000 psi. Use Graco replacement parts or accessories
that are rated a minimum of 3000 psi.
•Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.
•Verify that all connections are secure before operating the unit.
•Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.
4313034A
Warnings
WAR NING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•Always wear appropriate gloves, eye protection, and a respirator or mask when painting.
•Do not operate or spray near children. Keep children away from equipment at all times.
•Do not overreach or stand on an unstable support. Keep effective footing and balance at all
times.
•Stay alert and watch what you are doing.
•Do not operate the unit when fatigued or under the influence of drugs or alcohol.
•Do not kink or over-bend the hose.
•Do not expose the hose to temperatures or to pressures in excess of those specified by Graco.
•Do not use the hose as a strength member to pull or lift the equipment.
ELECTRIC SHOCK HAZARD
Improper grounding, setup, or usage of the system can cause electric shock.
•Turn off and disconnect power cord before servicing equipment.
•Use only grounded electrical outlets.
•Use only 3-wire extension cords.
•Ensure ground prongs are intact on sprayer and extension cords.
•Do not expose to rain. Store indoors.
PRESSURIZED ALUMINUM PARTS HAZARD
Do not use 1, 1, 1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or
fluids containing such solvents in pressurized aluminum equipment. Such use can cause serious
chemical reaction and equipment rupture, and result in death, serious injury, and property damage.
BURN HAZARD
Equipment surfaces can become very hot during operation. To avoid severe burns, do not touch
hot equipment. Wait until equipment has cooled completely.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
•Keep clear of moving parts.
•Do not operate equipment with protective guards or covers removed.
•Pressurized equipment can start without warning. Before checking, moving, or servicing
equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air
supply.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled,
or swallowed.
•Read MSDS’s to know the specific hazards of the fluids you are using.
•Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of
toxic fumes, burns, and hearing loss. This equipment includes but is not limited to:
•Protective eye wear
•Clothing and respirator as recommended by the fluid and solvent manufacturer
•Gloves
•Hearing protection
313034A5
Installation
Grounding and Electric
Requirements
Installation
Smaller gauge or longer extension cords may
reduce sprayer performance.
Sprayer must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for electrical current due to static build
up or in the event of a short circuit.
•The 120 Vac sprayers require a 120
Vac, 60 Hz, 15A circuit with a grounding receptacle.
•Never use an outlet
that is not grounded
or an adapter.
•Do not use the sprayer if the
electrical cord has a damaged ground prong.
•Only use an extension cord
with an undamaged 3-prong
plug.
ti5573a
ti5572a
Fluid supply container
Solvent pails used when flushing
code. Use only conductive metal pails, placed on a
grounded surface such as concrete. Do not place
the pail on a nonconductive surface, such as paper
or cardboard, which interrupts grounding continuity.
Grounding the metal pail
to the pail by clamping one end to pail and other
end to ground such as a water pipe.
Maintaining grounding continuity when flushing or relieving pressure: hold metal part
of the spray gun firmly to the
side of a grounded metal pail,
then trigger the gun.
: follow local code.
: follow local
: connect a ground wire
ti9207a
Thermal Overload
Motor has a thermal overload switch to shut itself
down if overheated. If unit overheats, allow approximately 45 minutes for unit to cool. Once cool,
switch will close and unit will restart.
Recommended extension cords for use with
this sprayer:
•50 ft (15.0 m) 14 AWG (2.1 mm
•100 ft (30.0 m) 12 AWG (3.3 mm
Spray gun
erly grounded fluid hose and pump.
6313034A
: ground through connection to a prop-
2
)
2
)
To reduce risk of injury from motor starting unexpectedly when it cools, always turn power switch
OFF if motor shuts down.
Component Identification
Component Identification
AAirless spray gunDispenses fluid.
BPower switchTurns sprayer ON and OFF.
CPressure control knob
C1Setting Indicator
DPump fluid outlet fittingThreaded connection for paint hose.
InstaClean
E
(ProLTS Sprayers only)
Power-Piston
(behind Easy Access
F
door, not shown)
™
fluid filter
™
Pump
(ProLTS Sprayers only)
Easy Access door
F1
(ProLTS Sprayers only)
GSuction tubeDraws fluid from paint pail into pump.
HPrime tube (with diffuser)Drains fluid in system during priming and pressure relief.
Increases (clockwise) and decreases (counter-clockwise) fluid pressure
in pump, hose, and spray gun.
To select function, align symbol on pressure control knob with setting
indicator, page 9.
•Filters fluid coming out of pump to reduce tip plugging and improve
finish.
•Self cleans only during pressure relief.
Pumps and pressurizes fluid and delivers it to paint hose.
Easy Access door permits quick access to outlet valve. To remove door,
insert flat blade of screwdriver into slot on the bottom of the door (as
shown on page, 7).
•In PRIME position (pointing down) directs fluid to prime tube.
JPrime/Spray valve
•In SPRAY position (pointing forward) directs pressurized fluid to
paint hose.
•Automatically relieves system pressure in overpressure situations.
Storage compartment
K
(ProLTS Sprayers only)
Provides onboard storage for spray tips and/or tools.
LInlet screenPrevents debris from entering pump.
MPaint hose Transports high-pressure fluid from pump to spray gun.
Fold-n-Store
N
(ProLTS Sprayers only)
™
Handle
Used to fold cart frame for hanging on wall.
QTip guardReduces risk of fluid injection injury.
•Atomizes fluid being sprayed, forms spray pattern and controls fluid
RReversible spray tip
flow according to hole size.
•Reverse unclogs plugged tips without disassembly.
Gun trigger safety lever
S
(page 9)
Prevents accidental triggering of spray gun.
TGun fluid inlet fittingThreaded connection for paint hose.
UPower Flush attachment
Connects garden hose to suction tube for power flushing water-base
fluids.
VGun fluid filter Filters fluid entering spray gun to reduce tip clogs.
Permits quick access to inlet valve to clear debris (ProLTS 19 only).
ti9724a
Component Identification
W
ti9346a
U
B
K
J
F1
F
ti9670a
N
H
C
X
C1
G
ti9368a
ti9669a
AA
E
D
L
R
S
Q
M
A
ti11988a
T
ti11987a
V (SG2/SG3)
8313034A
Operation
Operation
Tri gger Lock
Always engage the trigger lock when you stop
spraying to prevent the gun from being triggered
accidentally by hand or if dropped or bumped.
ti8908a
Trigger Locked
ti8909a
Trigger Unlocked
Pressure Relief Procedure
Follow this Pressure Relief Procedure whenever
you stop spraying and before cleaning, checking,
servicing, or transporting equipment.
2. Turn Prime/Spray valve to
PRIME to relieve pressure.
ti9346a
3. Hold gun firmly to side of
pail. Trigger the gun to
relieve pressure.
ti11986a
4. Engage trigger lock.
ti8908a
Leave Prime/Spray valve in the PRIME
position until you are ready to spray again.
1. Turn power switch OFF and unplug
power cord.
If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen tip
guard retaining nut or hose end coupling to relieve
ti2810a
pressure gradually, then loosen completely. Clear
hose or tip obstruction. Read Unclogging Spray
Tip, page 13.
Pressure Control Knob Settings
High Pressure
Spray
Low Pressure
Spray
To select function, align symbol on pressure control knob with setting indicator on sprayer.
Prime/
Clean
Rolling
ti5597a
313034A9
Setup
1. Unscrew tip and guard
assembly from gun.
2. Uncoil hose and connect
one end to gun. Use two
wrenches to tighten
securely
3. Connect other
end of hose to
sprayer.
ti11456a
(LTS)
If hose is already connected, make sure
connections are tight.
4. Turn OFF power switch.
ti11978a
ti11977a
ti9674a
(ProLTS)
Setup
Prime and Flush Storage Fluid
To spray lacquers with the ProLTS 17 or ProLTS 19, you must purchase lacquer conversion
kit 256212, and follow priming procedure for
oil-based materials. The LTS 15 and LTS 17
units are not intended for lacquers.
Before you use your sprayer for the first time or begin a
new spraying project, you need to prime the sprayer and
flush the storage fluid out of the sprayer.
Oil- or Water-based Materials
•When spraying water-based materials,
flush the system thoroughly with water.
•When spraying oil-based materials, flush
the system thoroughly with mineral spirits
or compatible, oil-based flushing solvent.
•To spray water-based materials after spraying oil-based materials, flush the
system thoroughly with water first. The
water flowing out of prime tube should be
clear and solvent-free before you begin
spraying the water-based material.
•To spray oil-based materials after spray-ing water-based materials, flush the system thoroughly with mineral spirits or a
compatible oil-based flushing solvent first.
The solvent flowing out of the prime tube
should not contain any water.
•When flushing with solvents, ground pail
ti2810a
and gun. Read Grounding and Electric
Requirements, page 6.
5. Turn Pressure Control Knob
all the way left
(counter-clockwise) to
•To avoid fluid splashing back on your skin
or into your eyes, always aim gun at inside
wall of pail.
minimum pressure.
ti9344a
1. Make sure the power switch is
OFF and the sprayer is
unplugged.
ti2810a
10313034A
Setup
2. Separate prime tube (smaller)
from suction tube (larger).
3. Place prime tube in waste
pail.
4. Submerge suction tube in
water or flushing solvent.
5. Turn Prime/Spray Valve to
PRIME.
ti2039a
ti9652a
ti9651a
10. Turn power switch OFF.
ti2810a
11. Transfer suction tube to
paint pail and submerge
suction tube in paint.
ti9653a
12. Turn power switch ON.
ti5580a
13. When you see paint coming
out of prime tube:
a. Point gun into waste pail.
b. Unlock gun trigger lock.
c. Pull and hold gun trigger.
ti8909a
d. Turn Prime/Spray valve
to SPRAY.
ti9346a
6. Plug sprayer in a grounded outlet.
7. Turn power switch ON.
ti5580a
8. Align setting indicator with
Prime/Clean setting on
Pressure Control knob until
pump starts, page 9.
ti9718a
9. When sprayer starts pumping, flushing solvent
and air bubbles will be purged from system.
Allow fluid to flow out of prime tube, into waste
pail, for 30 to 60 seconds.
14. Continue to trigger gun into
waste pail until you see only
paint coming out of gun.
15. Release trigger. Engage
trigger lock.
16. Transfer prime tube to paint
pail and clip prime tube to
suction tube.
•Motor stopping indicates pump and hose
are primed with paint.
•If motor continues to run the sprayer is not
properly primed. To reprime repeat step 8.
ti9345a
ti8908a
313034A11
Loading...
+ 23 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.