Graco 248421, 248418, 248419, 248417 User Manual

Instructions - Parts List
CleanLine
For petroleum-based oils, synthetic oils and anti-freeze* mixtures.
Not for use in explosive atmospheres.
*CleanLine 1800 filters must be used for anti-freeze mixtures, CleanLine 900 filters are not compatible with anti-freeze.
900 psi (6.2 Mpa 62 bar) Maximum Working Pressure
Model 248421 Pump Mount CleanLine 900 Filter Assembly
900 psi (6.2 Mpa 62 bar) Maximum Working Pressure
Model 248417 Wall Mount CleanLine 1800 Filter Assembly
1800 psi (12.4 Mpa 124 bar) Maximum Working Pressure
Model 248419 Pump Mount CleanLine 1800 Filter Assembly
1800 psi (12.4 Mpa 124 bar) Maximum Working Pressure
Filter
310652K
ENG
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
Model 248421 shown
TI6278B

Warnings

Warnings
The following warnings include general safety information for this equipment. More specific warnings are included in the text where applicable.
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Seek immediate surgical
treatment.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Follow the Pressure Relief Procedure in this manual, when you replace the filter.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
Read MSDS’s to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not alter or modify equipment.
For professional use only.
Use equipment only for its intended purpose. Call your Graco distributor for information.
Comply with all applicable safety regulations.
2 310652K

Installation

Installation
The CleanLine Filter™ is installed upstream from the dispense equipment. It can be pump or wall-mounted.
Wall Mount Clean Line 900 Installation Wall Mount Clean Line 1800 Installation
K
J
F
FIG. 1
KEY DESCRIPTION, See F
E Fluid shut-off valves (two)
F Air Regulator
G CleanLine Filter System
HPump *
J Filter and Lubricator Assembly
K Master Bleed Air Valve (ball valve)
* Do not use diaphragm pumps in a Matrix system.
† Special pump packages are required for anti-
freeze. See instruction manual 310650.
H
E
G
ti10680a
IG. 2.
K
J
F
FIG. 2
KEY DESCRIPTION, See F
Thermal Pressure Relief Kit must be
D
installed downstream from the pump. The Thermal Pressure Relief Kit will vary based on the pump selected. See manual 308403.
E Fluid shut-off valves (two)
F Air Regulator
G CleanLine Filter System
H Pump * †
J Filter and Lubricator Assembly
K Master Bleed Air Valve (ball valve)
* Do not use diaphragm pumps in a Matrix system.
† Special pump packages are required for anti-
freeze. See instruction manual 310650.
H
D
E
G
IG. 2.
ti5127
310652K 3
Installation
Wall-mount
1. Fasten the wall-mount bracket (part no. 249568) to the wall using screws long enough to provide secure support. See F
2. Observe the flow-direction arrows on the top of the filter assembly. See F bly correctly and secure the assembly to the bracket using four screws (10) for models 248418 and 248421 or three screws (107) for models 248417 and 248419.
F
IG. 3
IG. 3.
IG. 5. Position the filter assem-
Part No. 249568 Wall Mount
F
Part No. 249565 Pump Mount
IG. 4
Pump-mount
1. Attach the pump-mount bracket (part no. 249565) to the base of the pump. See F attachment will vary by pump. The Fire-Ball 425 6:1 and 425 10:1 pumps use machine screws to mount the bracket into pre-tapped holes tn the pump base. The 425 3:1 is not compatible with the pump mount bracket. The Fire-Ball 225 and 300 series pump bases are not tapped. You will need to use the machine screws and lock-nuts provided with bracket kit 249565.
2. Observe the flow-direction arrows on the top of the filter assembly. See F
IG. 5. Position the filter assem-
bly correctly and secure the assembly to the bracket using four screws (10) for models 248418 and 248421 or three screws (107) for models 248417 and 248419.
CleanLine 900
1. Install barbed fitting (9) and pressure relief tube (12) as shown in F
IG. 6. Apply thread sealant to threads
of barbed fitting (9).
IG. 4. The method of
CleanLine 900 Filter
Models 248418 and 248421
2. Route the tube (12) back to bulk tank or to used oil container.
F
IG. 5
4 310652K
CleanLine 1800 Filter
Models 248417 and 248419

Operation

Operation

Relieve Pressure

WAR NING
Follow Relieve Pressure procedure before replacing CleanLine Filter cartridge. Read warnings on page 2.
CleanLine 900 Filter (models 248418 and 248421)
1. Turn off air supply to pump.
2. Close upstream and downstream ball valves (6). See F
IG. 6.
3. Turn drain valve (4) slowly to relieve filter pressure.
System will release oil through pressure relief tube (12). Be sure tube is installed correctly. Drain valve (4) springs back to closed position.
Pressure Relief
1
Tube
Barbed Fitting
Apply thread sealant

Flush System

Flush the system before installing meters and for ongo­ing operation for all service fluids. Follow this procedure for each dispense location in the system, starting at the
location farthest from the pump.
WARNING
Follow Relieve Pressure procedure before replacing CleanLine Filter cartridge. Read warnings on page 2.
1. To determine the necessary flush time in minutes:
a. Measure the approximate length of the fluid line
from the filter outlet to the dispense end of the hose. Be sure to include the entire length of hose coiled in the hose reel.
b. Determine the largest inside diameter (I.D.) of
pipe or hose in the system.
c. On the following table, select the line length and
the larger I.D. of pipe or hose to determine flush time.
Flush Time (minutes)
Combined
length of pipe and
hose (feet)
50-100 ¹/
Drain Valve
100-200 ¹/
200-300 111¹/
TI5171C
1
Not to be routed to Matrix tank level monitor.
F
IG. 6
CleanLine 1800 Filter (models 248417 and 248419)
1. Turn off air supply to pump.
2. Close upstream ball valve (101).
3. Trigger the dispense valve.
4. Close downstream ball valve (101) to ensure oil does not run out.
310652K 5
300-400 11¹/
400-500 122¹/
500-750 1¹/
750-1000 23¹/
2. Install all system components including the Graco CleanLine Filter system. Do not install dispense equipment until initial flush is complete.
3. Close the fluid shut-off valve.
Largest inside diameter of pipe or
hose (inches)
.5 .625 .75 1.0 1.5
¹/
²
²
1124
2¹/
²
¹/
²
²
²
²
²
23¹/²8
3¹/
56¹/²20
12
36
²
410
²
6¹/
²
15
²
Operation
4. Ensure the main fluid outlet valve at the pump is closed.
5. Place dispense end of hose into a waste oil con­tainer. Secure the hose so it will not come out during flushing.
6. Slowly open the main fluid outlet valve at the pump. At the same time, gradually increase the air pres­sure to the pump until there is good flow through the hose.
7. Dispense fluid continuously at 2 gpm or more for the length of time determined by the table information. In an existing fluid line, the flushed oil can be returned to the bulk tank and reused. In a newly installed line, the flushed oil should be not be
reused.
8. Repeat this procedure for each dispense location and each service fluid in the system.
9. After service fluids have been flushed install meter(s).
10. The system is now ready for use.
4. Unscrew the filter (5).
5. Apply oil to the new filter seal.
6. Tighten new filter 1/10 turn after filter contacts base.
7. Open both ball valves (6).
8. Turn system pressure back on.
Replacing the filter cartridge allows air into the sys­tem. Spitting will occur during dispense until air is purged from the system.
CleanLine 1800 Filter (models 248417 and 248419)
1. Relieve pressure (see Relieve Pressure on page 5).
2. Close both ball valves (101).
3. Place a waste oil container below the filter to catch the oil in the housing (104) and filter cartridge (103).
4. Unscrew the housing (104).
5. Pull the filter cartridge (103) straight down.
It is all right to flush with mineral spirits, kerosene and other petroleum-based fluids with the Clean­Line Filter installed.

CleanLine Filter Cartridge Replacement

WAR NING
Follow Relieve Pressure procedure before replacing CleanLine Filter cartridge. Read warnings on page 2.
The CleanLine Filter cartridge should be replaced at least once a year or any time you notice a reduced flow rate or other signs of degraded performance. To replace the CleanLine Filter, perform the following steps:
CleanLine 900 Filter (models 248418 and 248421)
1. Relieve pressure (see Relieve Pressure on page 5).
6. Apply grease to the o-ring inside the replacement cartridge (103).
7. Firmly push the replacement cartridge (103) straight up, onto the nipple inside the manifold (102).
8. Replace the housing (104) and torque to 15 ft. lbs.
9. Open both ball valves (101).
10. Turn system pressure back on.
Replacing the filter cartridge allows air into the sys­tem. Spitting will occur during dispense until air is purged from the system.
2. Close both ball valves (6).
3. Place a waste container below the filter to catch the oil in the filter.
6 310652K
Operation
310652K 7

Parts for CleanLine 900 Filter

Parts for CleanLine 900 Filter
Model 248418 Wall Mount CleanLine Filter Assembly Model 248421 Pump Mount CleanLine Filter Assembly
2
1314
12
3
17
16
6
To dispense system
4
7
1
Torque to 130-150 in-lb.
2
Apply sealant.
3
Route tube to used oil container or to bulk oil tank, not to TLM port.
14
2
9
10
11
8
18a
6
3
1
2
2
1
8
18b
5
From pump
TI5170E
Ref. Part Description Qty.
1 15E281 MANIFOLD, filter 1 2 234842 VALVE, drain 1 3 287389 BASE, valve 1 4 187625 HANDLE, valve, drain 1 5 15D702 FILTER, spin-on 1 6 119388 VALVE, ball, 3/4 2 7 111600 PIN, grooved 1 8 15H103 NIPPLE, pipe 2 9 114287 FITTING, barbed, 1/4 ID tube,
1/8 npt 10 111801 SCREW, cap, hex head 4 11 15E328 LABEL, product ID filter 1 12 15E327 TUBE, pressure relief 1 13 119529 FITTING, barbed, 1/4 ID tube,
3/8 npt 14 119454 CLAMP, worm drive 2 15 110110 SEALANT, pipe (not shown)
8 310652K
Ref. Part Description Qty.
16 249568 BRACKET, wall mount for 248418
Includes label (11)
17249565 KIT, pump mount bracket for
248421 (includes pump mounting hardware and label (11)
18au 111010 HOSE, 3/4” x 10’, coupled 3/4 npt
(mbe) for wall mount model 248418
18bH 109105 HOSE, 3/4” x 6’, coupled 3/4 npt
1
19* 113344 FITTING, swivel (connects Fire-Ball
20* 157785 FITTING, swivel (connects Fire-Ball
1
u Model 248418 H Model 248421 * Not shown
(mbe) for pump mount model 248421
300 fluid out to hose (18)
424 fluid out to hose (18)
1
1
1
1
1

Parts for CleanLine 1800 Filter

Model 248417 Wall Mount CleanLine Filter Assembly
Model 248419 Pump Mount CleanLine Filter Assembly
To dispense system
101
Torque to 15 ft-lb.
1
106
105
102
107
112
110
106
105
Parts for CleanLine 1800 Filter
109
101
111a 111b
1
Ref. No. Part No. Description Qty.
101 119388 VALVE, ball 2 102 119189 MANIFOLD, filter 1 103 119278 ELEMENT, filter 1 104 119279 HOUSING, filter 1 105 15H103 NIPPLE, pipe 2 106 119200 FITTING, adapter, SAE12-3/4
npt(f) 107 113802 SCREW, hex head, flanged 3 108 110110 SEALANT, pipe (not shown) 109249568 BRACKET, wall mount for 248418
Includes label (112) 110249565 KIT, pump mount bracket for
248421(includes pump mounting
hardware and label (112)
103
A CleanLine Filter must be used when you use a Matrix fluid management system to dispense oil or anti-freeze. For anti-freeze mixtures, use the CleanLine 1800 wall mount unit (248417), CleanLine 900 Filters are not compatible with anti-freeze.
From pump
Ref. No. Part No. Description Qty.
111a111010 HOSE, 3/4” x 10” coupled 3/4 npt
(mbe) on wall mount for model 248417
111b109105 HOSE, 3/4” x 6’, coupled 3/4 npt
(mbe) on tank mount model
2
112 15E328 LABEL 1 113* 113344 FITTING, swivel (connects
114* 157785 FITTING, swivel (connects
1
1
Model 248417
Model 248419
* Not shown
248419
Fire-Ball 300 fluid out to hose (18)
Fire-Ball 424 fluid out to hose (18)
TI6276B
1
1
1
1
310652K 9

Technical Data

Technical Data
Maximum Working Pressure
CleanLine 900 Filter (models 248418 and 248421) 900 psi (6.2 MPa, 62 bar)
CleanLine 1800 Filter (models 248417 and 248419) 1800 psi (12.4 MPa, 124 bar)
Outlet 3/4 x 14 npt
Filtration Efficiency
CleanLine 900 Filter (models 248418 and 248421)
CleanLine 1800 Filter (models 248417 and 248419)
ß
= 1000 (ISO 16889)
14
= 1000 (ISO 16889)
ß
10
Wetted parts
CleanLine 900 Filter (models 248418 and 248421)
CleanLine 1800 Filter (models 248417 and 248419)
zinc plated steel, filter media
aluminum, filter media
Weight (dry) 7 lbs. (3.18 Kg.)
1
For particle sizes 14 micron and larger, filtration is 99.9% efficient.
2
For particle sizes 10 micron and larger, filtration is 99.9% efficient.
3
The filter media is compatible with petroleum-based fluids and most phosphate esters, water/oil emulsions, and high water content fluids.
1
2
3
3
Flow Characteristics
Flow measurements were made with 32cSt [150 SSU] hydraulic oil at 100°F (37.7°C), fluid specific gravity of 0.9.
Corrections:
Pressure Drop vs. Flow
3.5
3
2.5
2
1.5
1
Pressure Drop (psi)
0.5
0
0 5 10 15 20 25
Flow (gpm)
To correct filter element pressure drops for various viscosities and specific gravities, use one of the following formulae:
ΔPm = ΔPe x (SSU/150) x S.G./0.9) or ΔPm = ΔPe x (cSt/32) x S.G./0.9) or ΔPm = ΔPe x (cP/29)
Calculation Definitions:
ΔPe = Element pressure drop from curve
ΔPm = Corrected element pressure drop
S.G. = New specific gravity
SSU = New SSU viscosity
(Saybolt Seconds Universal)
cSt = New cSt viscosity (centistokes)
cP = New cP viscosity (centipoise)
10 310652K

Dimensions

Dimensions
12.25”
Part No. 249565
13”
7”
2.25”
.75”
Part No. 249568
4”
5.5”
7”
.375”
2.25”
2”
Part No. 249568 mounting hole positions
4”
6”6”
310652K 11

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 310652
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2004, Graco Inc. is registered to ISO 9001
www.graco.com
Revised 03/2010
Loading...