INSTRUCTIONS–PARTS LIST
309306
This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.
INSTRUCTIONS
STAINLESS STEEL
245081 Agitator Kit
FOR TRITONt 308 SPRAY PACKAGES
100 psi (0.7 MPa, 7.0 bar) Maximum Air Inlet Pressure
Rev. A
First choice when
quality counts.t
Agitator Kit shown installed on
TRITON 308 spray package (not included)
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
ECOPYRIGHT 2001, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001
ti1027a
Installation
1. Relieve the pressure as explained in the TRITON
Operation manual 309305.
2. Disconnect the air supply line from the bleed-type
master air valve (A). See the parts drawing on
page 3.
3. Remove the plug from the agitator port in the pail
cover.
4. Install the mounting collar (5) in the port so the
setscrew hole faces outward. Secure the collar
with the collar nut (6).
5. Remove the nut and agitator blade. Lower the
agitator (1) through the mounting collar as shown.
Reattach the blade and nut.
6. Install the setscrew (7) in the mounting collar (5)
and tighten it against the agitator shaft.
7. Screw the 1/8 npt elbow (2) into the air inlet port of
the agitator’s speed control.
8. Screw the tee (4) into the bleed-type master air
valve (A).
9. Screw the 1/4 npt elbow (3) into the branch of the
tee (4).
10. Connect the 1/4 in. (6.3 mm) OD tubing (8) between the two elbows (2, 3). Make sure the tubing
is securely fastened.
11. Ground the agitator as explained in the agitator
manual 306565.
12. Connect the air supply line to the tee (4).
13. Refer to the agitator manual 306565 for agitator
operating instructions, service, and parts information.
3093062