Instructions
Hopper Kit for GH5040ES, GH733ES,
GH933, and GH933ES Big Rig Sprayers
Model 16U505
Series Maximum Working Pressure
GH733ES Bare 4000 psi (27.6 MPa, 276 bar)
GH5040ES Bare 5000 psi (34.5 MPa, 345 bar)
GH933ES Bare 7250 psi (50.0 MPa, 500 bar)
GH933 Bare 7250 psi (50.0 MPa, 500 bar)
IMPORTANT SAFETY INSTRUCTIONS
Read all warnings and instructions in
sprayer manual. Save these instructions.
Related Manuals:
332156
332157
332158
332234A
EN
ti20999a
Pressure Relief Procedure
System pressure must be manually relieved to prevent it from starting or spraying accidentally. Fluid under high pressure can be
injected into the skin and cause serious injury. To reduce risk of injury from injection, follow this procedure whenever you are instructed
to relieve pressure, stop spraying, service equipment or install or clean spray tip. Read warnings, in operation manual.
1. Set pump valve OFF. Turn engine OFF.
2. Turn pressure to lowest setting. Trigger gun into pail to relieve pressure.
3. Rotate handle counter-clockwise to open prime valve.
If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the
steps above, VERY SLOWLY, loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen
completely. Then clean tip and hose.
Parts Drawing
2
1
Hopper Kit Instructions
Initial Setup
1. Follow Pressure Relief Procedure on page 1.
2. Remove fitting from bottom of pump.
3. Apply sealant to nipple (5). Assemble to female fitting
(6) and female fitting (4) and tighten.
4. Apply sealant to male fitting (3) and tighten to hopper
(1).
5. Apply sealant to bottom of pump and assemble
subassembly from step 3.
7
8
8
ti21000a
3
4
5
6
Parts List
Ref. Part Description Qty.
1 16U536 HOPPER, weldment
2 16U537 COVER, weldment
3 120307 FITTING, hose adapter, male
4 120308 FITTING, hose adapter, female
5 108209 NIPPLE, pipe
6 126939 FITTING, elbow, 90, female, reducing
7 16U538 BRACKET, mount, hopper
8 111195 SCREW, cap, flnghd
10 110110 SEALANT pipe, sst
6. Loosely install bracket (7) with two screws (8) into
pump bracket.
7. Install hopper assembly (1) into subassembly from
step 4 and tighten quick disconnect fitting (4).
8. Push bracket (7) up to secure hopper.
9. Tighten screws (8) to 30-35 ft-lb.
Removal
1. Loosen quick disconnect fitting (4).
2. Remove hopper.
Installation
1. Set hopper on bracket (7).
2. Rotate hopper into quick disconnect fitting (4).
1
3. Tighten quick disconnect fitting (4).
1
1
1
1
1
1
2
1
All written and visual data contained in this document reflects the latest product information available at the time of publication.
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2012, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.
Original instructions.
International Offices: Belgium, China, Japan, Korea
This manual contains English. MM 332234
Graco Headquarters: Minneapolis
www.graco.com
Revision A - January 2013