GORMAN‐RUPP OF CANADA LIMITED ST. THOMAS, ONTARIO, CANADAPrinted in U.S.A.
2000 The Gorman‐Rupp Company
Register your new
Gorman‐Rupp pump online at
www.grpumps.com
Valid serial number and e‐mail address required.
RECORD YOUR PUMP MODEL AND SERIAL NUMBER
Please record your pump model and serial number in the
spaces provided below. Your Gorman‐Rupp distributor
needs this information when you require parts or service.
Pump Model:
Serial Number:
TABLE OF CONTENTS
INTRODUCTIONPAGE I - 1.................................................
WARNINGS - SECTION APAGE A - 1.......................................
INSTALLATION - SECTION BPAGE B - 1....................................
Pump DimensionsPAGE B - 1.....................................................
PREINSTALLATION INSPECTIONPAGE B - 2............................................
POSITIONING PUMPPAGE B - 2.......................................................
LiftingPAGE B - 2.................................................................
MountingPAGE B - 2.............................................................
SUCTION AND DISCHARGE PIPINGPAGE B - 2.........................................
MaterialsPAGE B - 2..............................................................
Line ConfigurationPAGE B - 2......................................................
Connections to PumpPAGE B - 3..................................................
GaugesPAGE B - 3...............................................................
SUCTION LINESPAGE B - 3...........................................................
FittingsPAGE B - 3...............................................................
StrainersPAGE B - 3..............................................................
SealingPAGE B - 3...............................................................
Suction Lines In SumpsPAGE B - 3.................................................
Suction Line PositioningPAGE B - 4................................................
DISCHARGE LINESPAGE B - 4........................................................
SiphoningPAGE B - 4.............................................................
ValvesPAGE B - 4................................................................
ALIGNMENTPAGE B - 5..............................................................
Coupled DrivesPAGE B - 5........................................................
V-Belt DrivesPAGE B - 5.........................................................
OPERATION - SECTION CPAGE C - 1......................................
PRIMINGPAGE C - 1.................................................................
Hand PrimersPage C - 1..........................................................
Exhaust PrimersPage C - 1.......................................................
Auxiliary EjectorsPage C - 2.......................................................
Vacuum PumpsPage C - 2........................................................
STARTINGPAGE C - 2................................................................
RotationPage C - 2..............................................................
OPERATIONPAGE C - 2..............................................................
LeakagePAGE C - 2..............................................................
Liquid Temperature And OverheatingPAGE C - 2.....................................
Strainer CheckPAGE C - 3.........................................................
Pump Vacuum CheckPAGE C - 3..................................................
STOPPINGPAGE C - 3................................................................
Cold Weather PreservationPAGE C - 3..............................................
BEARING TEMPERATURE CHECKPAGE C - 4..........................................
TROUBLESHOOTING - SECTION DPAGE D - 1..............................
PREVENTIVE MAINTENANCEPAGE D - 3...............................................
i
TABLE OF CONTENTS
(continued)
PUMP MAINTENANCE AND REPAIR - SECTION EPAGE E - 1................
STANDARD PERFORMANCE CURVEPAGE E - 1........................................
PUMP MODEL - PARTS LISTPAGE E - 3...............................................
PUMP AND SEAL DISASSEMBLY AND REASSEMBLYPAGE E - 4.........................
Impeller RemovalPAGE E - 4......................................................
Seal RemovalPAGE E - 4..........................................................
Shaft And Bearing Removal And DisassemblyPAGE E - 5.............................
Shaft And Bearing Reassembly And InstallationPAGE E - 6............................
Seal Reassembly and InstallationPAGE E - 7........................................
Impeller InstallationPAGE E - 8.....................................................
Final Pump AssemblyPAGE E - 8..................................................
LUBRICATIONPAGE E - 8.............................................................
Seal AssemblyPAGE E - 8.........................................................
BearingsPAGE E - 8..............................................................
Power SourcePAGE E - 9.........................................................
ii
VG SERIESOM-02819
INTRODUCTION
Thank You for purchasing a Gorman‐Rupp pump.
Read this manual carefully to learn how to safely
install and operate your pump. Failure to do so
could result in personal injury or damage to the
pump.
This pump is a VG Series, enclosed impeller, cen
trifugal model with straight‐in suction without a
suction check valve. The pump is designed for
high pressure distribution of liquids containing
specified entrained solids. The basic material of
construction for wetted parts is gray iron. Be sure
the liquid being pumped is compatible with this
material.
This manual will alert personnel to known proce
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per
sonnel to ensure that only safe, established main
tenance procedures are used, and that any proce
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac
tices.
For information or technical assistance on the
power source, contact the power source manufac
turer's local dealer or representative.
The following are used to alert maintenance per
sonnel to procedures which require special atten
tion, to those which could damage equipment, and
to those which could be dangerous to personnel:
Immediate hazards which WILL result in
severe personal injury or death. These
instructions describe the procedure re
quired and the injury which will result
from failure to follow the procedure.
Hazards or unsafe practices which
COULD result in severe personal injury
or death. These instructions describe
the procedure required and the injury
which could result from failure to follow
the procedure.
If there are any questions regarding the pump or
its application which are not covered in this man
ual or in other literature accompanying this unit,
please contact your Gorman‐Rupp distributor or
the Gorman‐Rupp Company:
The Gorman‐Rupp Company
P.O. Box 1217
Mansfield, Ohio 44901-1217
Phone: (419) 755-1011
or:
Gorman‐Rupp of Canada Limited
70 Burwell Road
St. Thomas, Ontario N5P 3R7
Phone: (519) 631-2870
Hazards or unsafe practices which COULD
result in minor personal injury or product
or property damage. These instructions
describe the requirements and the possi
ble damage which could result from failure
to follow the procedure.
NOTE
Instructions to aid in installation, operation, and
maintenance or which clarify a procedure.
PAGE I - 1INTRODUCTION
VG SERIESOM-02819
SAFETY - SECTION A
This information applies to VG Series
basic pumps. Gorman‐Rupp has no
control over or particular knowledge of
the power source which will be used.
Refer to the manual accompanying the
power source before attempting to be
gin operation.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Disconnect or lock out the power
source to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
make certain that the pump and all pip
ing connections are tight, properly sup
ported and secure before operation.
Do not operate the pump without the
guards in place over the rotating parts.
Exposed rotating parts can catch cloth
ing, fingers, or tools, causing severe in
jury to personnel.
Do not operate the pump against a
closed discharge valve for long periods
of time. If operated against a closed dis
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.
Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam
age to equipment. Suction and dis
charge hoses and piping must be re
moved from the pump before lifting.
This pump is designed to handle liquids
containing specified entrained solids.
Do not attempt to pump volatile, corro
sive, or flammable materials which may
damage the pump or endanger person
nel as a result of pump failure.
After the pump has been positioned,
Do not remove plates, covers, gauges,
pipe plugs, or fittings from an over
heated pump. Vapor pressure within the
pump can cause parts being disen
gaged to be ejected with great force. Al
low the pump to completely cool before
servicing.
PAGE A - 1SAFETY
INSTALLATION - SECTION B
OM-02819VG SERIES
Review all SAFETY information in Section A.
Since pump installations are seldom identical, this
section offers only general recommendations and
practices required to inspect, position, and ar
range the pump and piping.
Most of the information pertains to a standard
static lift application where the pump is posi
tioned above the free level of liquid to be pumped.
If installed in a flooded suction application where
the liquid is supplied to the pump under pressure,
some of the information such as mounting, line
OUTLINE DRAWING
configuration, and priming must be tailored to the
specific application. Since the pressure supplied
to the pump is critical to performance and safety,
be sure to limit the incoming pressure to 50% of
the maximum permissible operating pressure as
shown on the pump performance curve.
For further assistance, contact your Gorman‐Rupp
distributor or the Gorman‐Rupp Company.
Pump Dimensions
See Figure 1
sions of this pump.
for the approximate physical dimen
Figure 1. Pump Model VG8D3-B
PAGE B - 1INSTALLATION
OM-02819VG SERIES
PREINSTALLATION INSPECTION
The pump assembly was inspected and tested be
fore shipment from the factory. Before installation,
inspect the pump for damage which may have oc
curred during shipment. Check as follows:
a. Inspect the pump for cracks, dents, damaged
threads, and other obvious damage.
b. Check for and tighten loose attaching hard
ware. Since gaskets tend to shrink after dry
ing, check for loose hardware at mating sur
faces.
c. Carefully read all warnings and cautions con
tained in this manual or affixed to the pump,
and perform all duties indicated. Note the di
rection of rotation indicated on the pump.
Check that the pump shaft rotates counter
clockwise when facing the pump suction.
POSITIONING PUMP
Lifting
Use lifting equipment with a capacity of at least
3,510pounds (1592,1 kg). This pump weighs ap
proximately 702 pounds (318,4 kg), not including
the weight of accessories and base. Customer in
stalled equipment such as suction and discharge
piping must be removed before attempting to lift.
The pump assembly can be seriously
damaged if the cables or chains used to lift
and move the unit are improperly wrapped
around the pump.
Mounting
Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount
ing is essential for proper operation.
Only operate this pump in the direction in
dicated by the arrow on the pump body
and on the accompanying decal. Refer to
ROTATION in OPERATION, Section C.
d. Check all lubricant levels and lubricate as
necessary. Refer to LUBRICATION in the
MAINTENANCE AND REPAIR section of this
manual and perform duties as instructed.
e. If the pump and power source have been
stored for more than 12 months, some of the
components or lubricants may have ex
ceeded their maximum shelf life. These mustbe inspected or replaced to ensure maxi
mum pump service.
If the maximum shelf life has been exceeded, or if
anything appears to be abnormal, contact your
Gorman‐Rupp distributor or the factory to deter
mine the repair or updating policy. Do not put the
pump into service until appropriate action has
been taken.
The pump may have to be supported or shimmed
to provide for level operation or to eliminate vibra
tion.
SUCTION AND DISCHARGE PIPING
The size of the system piping is not always deter
mined by the nominal suction and discharge port
diameter. Factors such as suction lift, discharge
elevation, and friction losses for the complete sys
tem must be considered to be sure your applica
tion allows the pump to operate within the safe op
erating range shown on page E‐1. In any case, the
suction line should never be smaller than the pump
inlet.
Materials
Either pipe or hose maybe used for suction and
discharge lines; however, the materials must be
compatible with the liquid being pumped. If hose is
used in suction lines, it must be the rigid‐wall, rein
forced type to prevent collapse under suction. Us
ing piping couplings in suction lines is not recom
mended.
Line Configuration
Keep suction and discharge lines as straight as
possible to minimize friction losses. Make mini
PAGE B - 2INSTALLATION
OM-02819VG SERIES
mum use of elbows and fittings, which substan
tially increase friction loss. If elbows are necessary,
use the long‐radius type to minimize friction loss.
Connections to Pump
Before tightening a connecting flange, align it ex
actly with the pump port. Never pull a pipe line into
place by tightening the flange bolts and/or cou
plings.
Lines near the pump must be independently sup
ported to avoid strain on the pump which could
cause excessive vibration, decreased bearing life,
and increased shaft and seal wear. If hose‐type
lines are used, they should have adequate support
to secure them when filled with liquid and under
pressure.
Gauges
Most pumps are drilled and tapped for installing
discharge pressure and vacuum suction gauges.
If these gauges are desired for pumps that are not
tapped, drill and tap the suction and discharge
lines not less than 18 inches (457,2 mm) from the
suction and discharge ports and install the lines.
Installation closer to the pump may result in erratic
readings.
Strainers
If a strainer is furnished with the pump, be certain
to use it; any spherical solids which pass through a
strainer furnished with the pump will also pass
through the pump itself.
If a strainer is not furnished with the pump, but is
installed by the pump user, make certain that the
total area of the openings in the strainer is at least
three or four times the cross section of the suction
line, and that the openings will not permit passage
of solids larger than the solids handling capability
of the pump.
This pump is designed to handle up to 1 1/16 inch
(26,9 mm) diameter spherical solids.
Sealing
Since even a slight leak will affect priming, head,
and capacity, especially when operating with a
high suction lift, all connections in the suction line
should be sealed with pipe dope to ensure an air
tight seal. Follow the sealant manufacturer's rec
ommendations when selecting and applying the
pipe dope. The pipe dope should be compatible
with the liquid being pumped.
Suction Lines In Sumps
SUCTION LINES
To avoid air pockets which could affect pump prim
ing, the suction line must be as short and direct as
possible. When operation involves a suction lift, the
line must always slope upward to the pump from
the source of the liquid being pumped; if the line
slopes down to the pump at any point along the
suction run, air pockets will be created.
Fittings
Suction lines should be the same size as the pump
inlet. If reducers are used in suction lines, they
should be the eccentric type, and should be in
stalled with the flat part of the reducers uppermost
to avoid creating air pockets. Valves are not nor
mally used in suction lines, but if a valve is used,
install it with the stem horizontal to avoid air pock
ets.
If a single suction line is installed in a sump, it
should be positioned away from the wall of the
sump at a distance equal to 1 1/2 times the diame
ter of the suction line.
If there is a liquid flow from an open pipe into the
sump, the flow should be kept away from the suc
tion inlet because the inflow will carry air down into
the sump, and air entering the suction line will re
duce pump efficiency.
If it is necessary to position inflow close to the suc
tion inlet, install a baffle between the inflow and the
suction inlet at a distance 1 1/2 times the diameter
of the suction pipe. The baffle will allow entrained
air to escape from the liquid before it is drawn into
the suction inlet.
If two suction lines are installed in a single sump,
the flow paths may interact, reducing the efficiency
of one or both pumps. To avoid this, position the
suction inlets so that they are separated by a dis
PAGE B - 3INSTALLATION