10.1 ERROR CODES SHOWN ON THE DISPLAY ........................................................38
10.2 ERROR CODE MENU ...........................................................................................38
10.2.1 ACCESSING THE ERROR CODE MENU .......................................................38
10.2.2 INFORMATIONS IN THE ERROR CODE MENU ............................................38
10.2.3 INFO PAGE ....................................................................................................39
10.3 ERROR CODE LIST ..............................................................................................41
11 Cleaning the magnetic / Dirt filter Caleffi ....................................................................45
12 WATER PRESSURE IN THE SYSTEM .....................................................................46
EN
Installation, maintenance and
authorised person from Gorenje!
Pouring of water or any other
damage on the appliance!
Please read this instruction
This appliance is not intended for
person responsible for their safety!
1 BEFOREUSE
1.1 SAFETYWARNINGS
Warning Caution Prohibition
manual carefully before using for
the first time!
uninstallation of the heat pump
can only be performed by an
use by people with reduced physical,
sensory or mental capabilities, or
lack of experience or knowledge,
unless they have supervision by a
fluid on or in the appliance is
strictly prohibited! Failure to
comply can lead to injuries and
1
EN
Do not touch the air outlet grid
Do not touch the leaves of the
It is advisable to install a switch on
the nominal current of 300 mA.
Main
Power
Suppl
COMPACT Units (Indoor and Outdoor Unit
automatic anti-freezing protection.
Warning Caution Prohibition
when the fan motor is operating!
vaporiser – their sharp surface
can cause cuts!
IndoorUnit
the differential current (RCD) with
with water system connections) must be
always with power supply to prevent freezing
of the water in the piping. Unit has an
Warning:
The Compact Type heat pumps have a hydraulic connection, which means that the medium
in the pipes (water or a mixture of water and concentrate antifreeze) can freeze if the heat
pump is not under voltage for a longer time. This may cause major damage to the heat pump
and on the system itself. For further information, please contact an authorized Installer or
Gorenje HVAC.
2
EN
2 PRINCIPLE OF OPERATION OF THE HEAT PUMP
2.1 THEBASICPRINCIPLEOFOPERATIONOFAHEATPUMP
A heat pump operates similarly as a refrigerator. In a refrigerator, liquids evaporate due to
received thermal energy from the surrounding air and this energy is emitted at a desired spot
during condensation (Carnot’s cycle). A heat pump works in the opposite direction: it accepts
thermal energy from the surrounding air and emits it in heated premises, using the natural
heat collector of the environment. Ground and surface water, earth’s warmth, solar energy
and ambient air can be used as energy sources. The system is composed of four units:
evaporator, compressor, condenser and damper. Heat energy is transferred via the coolant.
In the evaporator, the coolant receives heat energy and evaporates. In the compressor, the
vapour is compressed, which makes it heat up intensively. This hot vapour transmits thermal
energy from the condenser to the heating water and liquefies. In the damper, the coolant
expands (pressure reduces to the starting pressure, from there it proceeds to the evaporator
and the cycle repeats).
2.2 INVERTERHEATPUMP
Inverter heat pumps use variable-speed compressors. Traditional heat pumps use fixed
power/rotation speed compressors. In inverter compressors, the compressor speed
constantly adapts to the heat losses of the room and the energy value of the source (air,
brine or water, depending on the system).
In traditional heat pumps, the power of the compressor is always the same. Compressor
starts with full power and when it achieves the desired values/temperatures, it shuts off and
waits until it restarts.
Inverter heat pumps work for a longer period of time, but with lower power (adjusting to the
premises), which means lower consumption of electric energy.
2.3 OPTIMISATIONOFHEATINGCOSTS
2.3.1 Selection of heat pump
The first step towards the optimisation of heating costs is selecting the appropriate heat
pump. An over-dimensioned or under-dimensioned heat pump can cause higher heating
costs and shorten the lifespan of the appliance.
2.3.2 Heating curve
A correctly set heating curve is of key importance for the optimisation of heating costs. If a
room thermostat is used, the heating curve must be adjusted to the building as if it was not
existent. A too highly set heating curve can cause up to 30% higher heating costs!
2.3.3 Domestic water
Incorrect or too highly set desired temperature of domestic water can significantly increase
heating costs! In a traditional system with a 100-litre boiler, where domestic water is heated
by a heating element, the temperature necessary for meeting the needs of an average family
is much higher than in a system where domestic water is heated by means of a heat pump.
The difference lies in the quantity of the water in the water storage tank.
With heat pumps special water storage tanks are used that have a larger volume than
traditional boilers! For a heat pump system, daily consumption of 50 litres is assumed,
multiplied by the number of users of domestic water.
Example:
Family of four – 4 persons x 50 litres = 200 litres
3
EN
2.3.4 In time of absence
Complete shutdown of a heat pump can lead to higher heating costs. We recommend using
the vacation mode, which lowers the temperature of heating and domestic water during your
absence, but does not allow the system to get completely cold, which would cause higher
heating costs upon system restart.
The next chapter describes how to make small steps to save a lot of energy.
3 HOWTOMAKESMALLCHANGESTO
REDUCEHEATINGCOSTS
Every degree counts!
The use of heating energy depends on the temperature of the room. In a heated
apartment, every degree above 20 means up to 6 % higher energy use, i.e. higher
cost.
All windows and doors must be properly sealed!
Old windows and doors are usually not completely sealed, so draft takes warmth out
of the apartment. If crannies are visible, it’s crucial to take action as soon as possible.
Try to solve the problem by sticking sealing tapes on the contact surfaces or cut
notches for plastic sealing profiles / set the hardware or seal the internal casements in
classic (box) windows with separate casements.
Correct ventilation!
To feel good we need enough oxygen in the air, and we can get fresh air by means of
ventilation. If done correctly, we use up to 20% less energy for heating. Ventilate by
opening the window for a few minutes. Do this three times per day in each room. The
lower the temperature of ambient air, the shorter the ventilation should be.
Do not cover heating elements!
If heating elements are covered, air pockets occur that waste energy. It is
recommended to have curtains that only reach the level of radiators. Covering heating
elements can increase energy use by up to 10 %.
Set the appropriate temperature!
Is your heating regulation set to automatic or do your kids use it? If you want to
select the correct temperatures for your living environment, please consult with
experts who will tell you what temperature is the best for each living space. Already
two degrees – 22 degrees instead of 20 – can cause 12 % higher energy
consumption!
Check the possible causes for high energy consumption related to heating
If you think that you are using excessive amounts of energy, it is advisable to check
among the multiple causes for high heat losses:
– Old radiator valves (where thermostat valves are not built in);
– Poor or damaged heat insulation on internal installations after the measuring
point;
– Poorly maintained internal installations;
– Decrepit or improperly set temperature regulation automatics;
– Poor heat insulation of buildings (esp. older ones);
– Poorly sealed windows (especially without insulated glazing);
4
EN
– Incorrect ventilation of premises (when ventilating rooms, make sure the
radiators are closed);
– The charged quantity of used heat for central heating of premises depends
mainly on the average outside temperature, so the consumption increases in
the start of the heating season, usually achieves the highest value in January,
and decreases at the end of the heating season;
– Longer accounting period than usual – may be caused by the inability to read
the status in the regular period, or if the ownership transfer documents arrived
too soon etc.;
– Incorrect operation of the measuring device;
– Status for the period of defect of the measuring device was determined based
on statistics.
Installation of heat cost allocators or calorimeters
If your apartment is in an old apartment building and you are paying for heat energy
consumption per square meter (flat rate), you can install heat cost allocators on
individual radiators in your apartment or, depending on the building, a calorimeter
before heating enters the apartment. In this case you can save heat energy
independently of your neighbour. However, in order to do this, more than one half of
apartment owners must be in favour of this with respect to the Rules on dividing and
billing heating costs in multiple-dwelling buildings. This way an individual apartment
building can save between 20 and 30 % of energy.
5
EN
AS (Split) series
All In One AS series
Digital Thermostat
- hold = ON/OFF;
- push = Rising of the desired
temperature
- hold = stting the tempearure
- push = lowering of the desired
tempearture
Digital Thermostat
- rising of the set temp.
- lowering of the set temp.
- setting the desired temp.
Mechanical Thermostat
(DHW)
4 EMERGENCYOPERATION
Emergency operation is the operation of a heat pump with auxiliary heating sources such as
electric heaters, gas furnace, oil furnace or other heating source controlled by the heat pump.
Emergency operation is divided into Automatic and Manual operation.
Automatic Emergency Mode:
If the control detects that it cannot run the heat pumps as sources of heating due to possible
errors, additional heating sources for heating system and heating sanitary water will be
automatically switched on.
Note: the current Heating and DHW set temperature is automatically reduced by 7°C.
Manual emergency mode:
Activating this mode is a responsibility of the end user. This method is used in the event of a
failure of the master controller when it cannot control the system.
The heat pump has a manual switch to activate the manual emergency operation (the signal
light on the switch lights-up when it is activated). At this moment, all settings on the main
controller become invalid, because the control of the desired temperatures is exclusively
controlled by the additional thermostats that are installed on the device.
On the digital thermostat, set the desired heating temperature and the desired DHW
temperature on the mechanical thermostat.
Note: If the Digital Thermostat is manually switched OFF, so that on teh screan are three red
lines - - - , the Automatic emergency operation will be disabled.
6
EN
Emergancy switch in OFF position – Heat pump works according to teh settings on the
main controller (tuch-screen controll panel)
Emergancy switch in ON position – Setting of teh main controller (tuch-screen controll
panel) will be disabled. All Circulating pumps (P0, P1, P2 an P3) start to work (always ON).
Temperature controll is only with Digital thermostat (controlling the set temperature of
electrical heaters). Diverting valve has to be set manualy to switch from Heating system to
DHW heating.
7
EN
gorenje
gorenje
1 2 1
4.1 LOCATIONOFTHEEMERGENCYSWITCH
ALL-IN-ONE Inverter AS
AEROGOR Inverters AS
8
EN
1. Digital thermostat controls the max flow temperature in case of Back-Up or Auto–
Emergency operation. In the Back-Up and Auto–Emergency operation, the Main
controller is still controlling the heating temperature.
Auto – Emergency operation
Example:
If the Unit turns ON the Back-Up heaters or Emergency operation and the setting on
the Digital thermostat is set to 30°C, the heaters will work only until 30°C and then
switch OFF regardless of the demand from the main controller. If, however the Digital
thermostat is set to 60°C, the Main controller will switch OFF the heaters according to
its needs.
Manual operation (manual emergency switch ON):
In manual operation all the circulating pumps are switched ON and the Electrical
heaters work according to the setting on the Digital thermostat, regardless of the
setting on the Main controller.
Example:
if the Manual emergency operation is ON and the temperature set on the Digital
thermostat is set to 50, the heating water will be heated to 50°C. The Circulating
pumps will run all the time.
2. Analog thermostat controls the max flow temperature in case of Back-Up or Auto –
Emergency operation for DHW. In Back-Up and Auto–Emergency operation, the Main
controller is still controlling the DHW temperature.
Auto – Emergency operation
Example:
If the Unit turns ON the Back-Up heaters or Emergency operation for DHW and the
setting on the thermostat is set to 40°C, the heaters will work only until 40°C and then
switch OFF regardless of the demand from the main controller. If however the
thermostat is set to 60°C, the Main controller will switch OFF the heaters according to
its needs (DHW set temperature).
9
EN
e) Display of current
operation mode
f) Additional features,
operation modes
g) Warning or Error
h) Power ON/OFF
i) Settings
a) Operation mode
b) Heating or cooling
f) Communication
g) Heating of
domestic water
5 CONTROLUNIT
5.1 DESCRIPTIONOFSYMBOLSONTHECONTROLUNIT
a) Operation mode
This symbol shows the operation mode of the heat pump. Two modes are possible:
automatic or manual operation mode. With a short push on this symbol you can
select the operation mode. The recommended setting is automatic mode.
Automatic operation mode
The heat pump automatically switches between heating or cooling the house and
heating of domestic water!
Manual operation mode
In the manual Operation mode, the heat pump only prepares what you have selected
and ignores timers and the ambient temperature!
Only heating of premises (without domestic water, cooling, timers…)
Only cooling of premises (without domestic water, heating, timers…)
Only domestic water (without heating, cooling, timers…)
10
Loading...
+ 37 hidden pages