PRODUCT SPECIFICATIONS
PCK SERIES
10 SEER
Packaged
Air Conditioner
2 to 5 Ton
Cooling Capacity: 23,200 - 58,000 BTUH
C
The PCK packaged air conditioner
allows for side-by-side ground-level or
rooftop application and is approved for
manufactured or modular homes.
Standard Features
• Hermetically sealed compressor with internal
relief valve
• Two-speed evaporator blower motor; low-speed for
normal or low-static application/high-speed for highstatic application in manufactured homes
• Totally enclosed, permanently lubricated condenser
fan motor
• Copper tube/aluminum fin coil
• Fully charged R-22 system
• Liquid line filter drier
• Quiet-operating top grille condenser discharge
• Fully insulated air handling compartment
• Bottom pan rails elevate the unit above the slab
• Convenient access panels
Cabinet Construction
• Powder-paint finish with 500-hour salt spray approval
• Fully insulated air handling compartment
• Convenient access panels
• When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for
hurricane-type winds
Accessories
• Roof Curb
• Downflow Plenum (includes filter rack)
• Manual Fresh Air Damper (to be used with
Downflow Plenum)
• Economizer (to be used with Downflow Plenum)
• Louvered Panel Kit (LPAK-00A, LPAK-01A,
LPAK-02A)
• Square-to-Round Duct Converter for Round Duct
applications (horizontal and downflow)
• Elbow and Flashing Downflow Kit
• Room Thermostat (CHT18-60)
• Outdoor Thermostat (OT18-60)
• Heat Kit from 5 to 20 kW with plug-in connection
Accessory Heat Kit Features
• Controlled by sequencers for better temperature
control (single-phase units only)
• Control circuitry arranged to readily permit staging
(HK10, 15, 20-1 only)
• Primary/secondary limit protection
• Rust-resistant nickel chromium heating elements
• Factory-installed circuit breakers on
certain models (see Electrical Data)
SS-278D
www.goodmanmfg.com
1/05
Supercedes 8/04
PRODUCT SPECIFICATIONS
Nomenclature
PCK 024 -1 F
Revision
Electrical Designator
1 - 208/230 VAC, 1 Ph, 60 Hz
3 - 208/230 VAC, 3 Ph, 60 Hz
4 - 460 VAC, 3 Ph, 60 Hz
Nominal Capacity
024 - 24,000 BTUH
030 - 30,000 BTUH
036 - 36,000 BTUH
042 - 42,000 BTUH
048 - 48,000 BTUH
060 - 60,000 BTUH
Unit Type
Packaged Air Conditioner
(2nd Generation)
All Units Are Direct Drive
Specifications
PCK024-1F PCK030-1F PCK036-1F PCK036-3F PCK042-1F
Total Cooling (BTUH)
Sensible Cooling (BTUH)
1
SEER
2
EER
a
Sound Rating (bels)
Indoor Blower
Type
Size (D” x W”)
Motor Horsepower
Evaporator Coil
Face Area (ft
Fins per Inch
No. of Rows
Outdoor Fan
Fan Diameter
Motor Horsepower
Condenser Coil
Face Area (ft
Fins per Inch
No. of Rows
Electrical
Ph
Volts
Compressor RLA
Compressor LRA
Indoor Blower FLA
Outdoor Blower FLA
Minimum Circuit Ampacity
Maximum Overcurrent Protection
Net Weight (pounds) 240 245 265 265 335
Shipping Weight (pounds) 255 260 280 280 350
(1) Certified per ARI 210
(2) BTU/Watt @ 80/67 °F inside - 95 °F outside air
Note - May use fuses or HACR type Circuit Breakers of the same size as noted.
2
)
2
)
23,200
16,800
10.0
9.0
8.0
DD
9 x 6
1/5
3.33
14
2
18”
1/6
12.1
19
1
1
208/230
9.8
56.0
1.7
1.0
15.0
20
28,400
20,600
10.0
9.0
8.0
DD
9 x 6
1/3
3.33
14
2
18”
1/6
12.1
19
1
1
208/230
13.8
75.0
2.6
1.0
20.9
30
35,000
25,600
10.0
9.0
8.0
DD
9 x 6
1/3
3.33
14
3
18”
1/6
12.1
19
1
1
208/230
16.2
96.0
2.6
1.0
23.9
40
35,000
25,600
10.0
9.0
8.0
DD
9 x 6
1/3
3.33
14
3
18”
1/6
12.1
19
1
3
208/230
10.3
75.0
2.6
1.0
16.5
20
208/230
42,000
32,000
10.0
9.0
8.4
DD
9 x 8
1/3
5.25
14
3
22”
1/4
14.7
19
1
1
17.1
105.0
2.6
1.6
25.6
40
2
PRODUCT SPECIFICATIONS
Specifications (cont.)
PCK048-1F PCK048-3F PCK060-1F PCK060-3F PCK060-4F
Total Cooling (BTUH)
Sensible Cooling (BTUH)
1
SEER
2
EER
a
Sound Rating (bels)
Indoor Blower
Type
Size (D” x W”)
Motor Horsepower
Evaporator Coil
Face Area (ft
Fins per Inch
No. of Rows
Outdoor Fan
Fan Diameter
Motor Horsepower
Condenser Coil
Face Area (ft
Fins per Inch
No. of Rows
Electrical
Ph
Volts
Compressor RLA
Compressor LRA
Indoor Blower FLA
Outdoor Blower FLA
Minimum Circuit Ampacity
Maximum Overcurrent Protection
Net Weight (pounds) 340 340 350 350 350
Shipping Weight (pounds) 365 365 375 375 375
(1) Certified per ARI 210
(2) BTU/Watt @ 80/67 °F inside - 95 °F outside air
Note - May use fuses or HACR type Circuit Breakers of the same size as noted.
2
)
2
)
46,000
35,800
10.0
9.0
8.4
DD
10 x 8
1/2
5.75
14
4
22”
1/4
14.7
19
1
1
208/230
18.3
102.0
3.6
1.6
28.2
40
46,000
35,800
10.0
9.0
8.4
DD
10 x 8
1/2
5.75
14
4
22”
1/4
14.7
19
1
3
208/230
12.6
91.0
3.6
1.6
21.0
30
58,000
43,500
10.0
9.0
8.4
DD
10 x 8
3/4
6.22
14
4
22”
1/3
16.2
19
1
1
208/230
25.0
170.0
5.1
2.5
38.9
60
58,000
43,500
10.0
9.0
8.4
DD
10 x 8
3/4
6.22
14
4
22”
1/3
16.2
19
1
3
208/230
15.5
124.0
5.1
2.5
27.0
40
58,000
43,500
10.0
9.0
8.4
DD
10 x 8
3/4
6.22
14
4
22”
1/3
16.2
19
1
3
460
7.5
59.6
2.2
1.2
12.8
20
3