BEFORE SERVICING THE UNIT, READ THE
SAFETY PRECAUTIONS IN THIS MANUAL.
CAUTION
SAFETY PRECAUTIONS
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE EXPOSURE
TO EXCESSIVE MICROWAVE ENERGY
a. Do not operate or allow the oven to be operated with the door open.
b. Make the following safety checks on all ovens to be serviced before activating the
magnetron or other microwave source, and make repairs as necessary; (1) Interlock
operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and
other damage), (4) damage to or loosening of hinges and latches, (5) evidence of
dropping or abuse.
c. Before turning on microwave power for any service test or inspection within the
microwave generating compartments, check the magnetron, wave guide or
transmission line, and cavity for proper alignment, integrity, and connections.
d. Any defective or misadjusted components in the interlock, monitor, door seal, and
microwave generation and transmission systems shall be repaired, replaced, or
adjusted by procedures described in this manual before the oven is released to the
owner.
e. A Microwave leakage check to verify compliance with the CSA Standard should be
performed on each oven prior to release to the owner.
• Proper operation of the microwave ovens requires that the magnetron be assembled to the
wave guide and cavity. Never operate the magnetron unless it is properly installed.
• Be sure that the magnetron gasket is properly installed around the dome of the tube whenever
installing the magnetron.
• Routine service safety procedures should be exercised at all times.
• Untrained personnel should not attempt service without a thorough review of the test
procedures and safety information contained in this manual.
FOREWORD
Read this Manual carefully. Failure to adhere to or observe the information in this Manual may result in exposing
yourself to the Microwave Energy normally contained within the oven cavity.
TABLE OF CONTENTS
(Page)
SAFETY PRECAUTIONS ........................................................................................................Inside front page
1,500W maximum (Microwave oven+Cook top lamp+Ventilation fan)
Adjustable 100W through 1000W, 10 steps
Open at 90°C±5°C
Fuse(20A)
Primary Interlock Switch
Secondary Interlock Switch
Interlock Monitor
Exhaust Adapter, Exhaust Damper, Mounting Kit and Two
Filters, Rotating Ring Assembly
1-1
CAUTIONS
Gasket
ANTENNA
COOLING FIN
MAGNETRON
CHASSIS GROUND
FILAMENT
TERMINALS
MAGNETRON
Unlike other appliances, the microwave oven is
high-voltage and high-current equipment.
Though it is free from danger in ordinary use,
extreme care should be taken during repair.
• DO NOT operate on a 2-wire extension cord during
repair and use.
• NEVER TOUCH any oven components or wiring during
operation.
• BEFORE TOUCHING any parts of the oven, always
remove the power plug from the outlet.
• For about 30 seconds after the oven stops, an electric
charge remains in the high voltage capacitor. When
replacing or checking, you must discharge the high
voltage capacitor by shorting across the two terminals
with an insulated screwdriver.
MICROWAVE RADIATION
Personnel should not be exposed to the
microwave energy which may radiate from the
magnetron or other microwave generating
device if it is improperly used or connection.
All input and output microwave connections,
waveguide, flange, and gasket must be secure
never operate the device without a microwave
energy absorbing load attached.
Never look into an open waveguide or antenna
while the device is energized.
• Proper operation of the microwave oven requires that
the magnetron be assembled to the waveguide and
cavity. Never operate the magnetron unless it is
properly installed.
• Be sure that the magnetron gasket is properly
installed around the dome of the tube whenever
installing the magnetron.
• Remove your watches whenever working close to or
replacing the Magnetron.
• DO NOT touch any parts of the control panel circuit. A
resulting static electric discharge may damage this
P.C.B.
• NEVER operate the oven with no load.
• NEVER injure the door seal and front plate of the oven
cavity.
• NEVER put iron tools on the magnetron.
• NEVER put anything into the latch hole and the
interlock switches area.
THE OVEN IS TO BE SERVICED ONLY
BY PROPERLY QUALIFIED SERVICE
PERSONNEL.
2-1
INSTALLATIONS
BEFORE YOU BEGIN, READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY.
PRECAUTIONS ON INSTALLATION
A. Plug the power supply cord into a 120V AC, 60Hz,
single-phase power source with a capacity of 15A
or 20A.
B. Avoid placing the unit in a location where there is
direct heat or splashing water.
C. Install the unit on the mounting plate firmly.
D. Place the unit as far away as possible from TV,
radio, etc. to prevent interference.
GROUNDING INSTRUCTIONS
For personal safety, this appliance must be fully
grounded at all times.
In the event of an electrical short circuit, grounding
reduces the risk of electrical shock.
The plug must be plugged into an outlet that is
properly installed and grounded.
CAUTION
This unit is equipped with a 3-prong plug for your
safety. If the wall outlet is a grounded 3-hole type,
the unit will be grounded automatically.
Plug with Ground
Prong
Properly Polarized
and Grounded
Outlet
WARNING
Improper use of the grounding plug can result in a
risk of electric shock.
Do not, under any circumstances, cut or remove the
third ground prong from the power cord plug.
3-1
CONTROL PANEL
4
7
10
14
15
16
19
9
21
24
26
23
1
5
8
17
20
22
25
18
11
13
6
3
2
12
OPERATING INSTRUCTIONS
4-1
CONTROL PANEL INSTRUCTIONS
1. DISPLAY: The Display includes a clock and
indicators to tell you time of day, cooking time
settings and cooking functions selected.
2. POPCORN: Touch this pad when popping popcorn
in your microwave oven.
3. PIZZA: Touch this pad to reheat 1 to 3 slices.
4. COOK: Touch this pad to cook vegetables, rice, or
casseroles.
5. POTATO: Touch this pad to cook potatoes from 1 to
4.
6. BEVERAGE: Touch this pad to reheat one cup or
two cups a beverage.
7. REHEAT: Touch this pad to reheat dinner plate,
soup/sauce, casserole, roll/muffin.
8. MORE: Touch this pad to add ten seconds of
cooking time each time you press it.
9. CUSTOM COOK: Touch this pad to recall one
cooking instruction previously programmed into
memory.
14. CUSTOM SET: Touch this pad to change the
oven’s default settings for sound, clock, display
speed and defrost weight.
15. CLOCK: Touch this pad to enter the time of day.
16. HOLD WARM: Touch this pad to keep hot, cooked
foods safety warm in your microwave oven for up
to 99 minutes 99 seconds.
17. TIME COOK: Touch this pad to set a cooking time.
18. POWER LEVEL: Touch this pad to select a
cooking power level.
19. HELP: Touch this pad to learn how to use each
oven function.
20. STOP/CLEAR: Touch this pad to stop the oven or
clear all entries.
21. START: Touch this pad to start a function. If you
open the door after oven begins to cook, retouch
start.
22. KITCHEN TIMER: Touch this pad to set the
kitchen timer.
10. LESS: Touch this pad to subtract ten seconds of
cooking time each time you press.
11. AUTO DEFROST: Meat, poultry, fish. Touch on
pad to select food type and defrost food by weight.
12. EZ ON: Touch this pad to set and start quickly at
100% power level.
13. NUMBER: Touch number pads to enter cooking
time, power level, quantities or weights.
23. TURNTABLE ON/OFF: Touch this pad to turn off
the turntable. “OFF” will appear in the display.
24. LIGHT TIMER: Touch this pad to set the light
timer.
25. FAN HI/LOW/OFF: Touch this pad to turn the fan
on or off.
26. LIGHT HI/LOW/OFF: Touch this pad to turn on the
cooktop/countertop light.
4-2
OVERALL CIRCUIT DIAGRAM
SCHEMATIC DIAGRAM
5-1
MATRIX CIRCUIT FOR TOUCH KEY BOARD
TIME
COOK
FAN
HI/LO/OFF
HELPCOOK
POPCORN
AUTO
DEFROST
LIGHT
HI/LO/OFF
CUSTOM
SET
REHEATPOTATO
KITCHEN
TIMER
CLOCKLESSEz On
BEVERAGE
POWER
LEVEL
CUSTOM
COOK
LIGHT
TIMER
N.CPIZZA
HOLD
WARM
T/TABLE
ON/OFF
STOP
CLEAR
STARTN.C
N.CN.CMOREN.CN.CN.CN.C
5-2
GENERAL INFORMATION FOR SERVICE
GENERAL PRECAUTIONS IN USE
A. Never operate the unit when it is empty.
Operating the oven with no load may shorten the
life of the magnetron. Whenever cooking dry foods
(dried fish, bread, etc.) or a small amount of food,
be sure to put a glass of water into the cooking
compartment. The glass turntable may become hot
after operating, be careful when touching it.
B. Aluminum foil should be avoided because it will
disrupt cooking and may cause arcing. However,
small pieces may be used to cover some parts of
food to slow the cooking. Any aluminum foil used
should never be closer than 2.5 cm to any side wall
of the oven.
TRIAL OPERATION
After installation, the following sequences and results
should be checked carefully.
A. Put a container filled with water (about 1 liter) into
the oven, and close the door tightly.
B. Set cooking time for 10 minutes by touching “1”
and then “0” three times. “1, 0, 0, 0” appears in
the display window.
C. Touch the START key.
Make sure the cavity light comes on. The unit will
begin cooking and the display window will show the
time counting down by seconds.
D. After about 5 minutes, make sure the primary
interlock switch, the secondary interlock switch and
the interlock monitor switch operate properly by
opening and closing the door several times. Touch
the START key each time the door is closed.
E. Continue operating the unit. Two short and a long
beep sound signal is heard when the time is up.
The unit will shut off automatically.
(Note: This thermostat located on the oven
cavity will open and stop the unit from operation
only if a high temperature is reached, such as, a
fire created by overcooking food.)
B. Any one of 10 power output levels ranging 100W to
1000W can be selected by the touch control and
electronic computer system.
FEATURES AND SPECIFICATIONS
FEATURES
A. The safety systems incorporated in this model are:
6-1
SERVICE INFORMATION
PRECAUTIONS AND REPAIR SERVICE TIPS
PRELIMINARY
A. SINCE NEARLY 2,100 VOLTS EXISTS IN SOME
CIRCUITS OF THIS UNIT REPAIRS SHOULD BE
CARRIED OUT WITH GREAT CARE.
The filament leads of magnetron carry High
Voltage with respect to ground. Extreme caution
must be exercised. Never plug the unit into a
power source to determine which component is
defective in high voltage section.
B. TO AVOID POSSIBLE EXPOSURE TO
MICROWAVE ENERGY LEAKAGE, THE
FOLLOWING PRECAUTIONS MUST BE TAKEN
BEFORE SERVICING.
(1) Before the power is applied:
(a) Make sure the primary interlock switch, the
secondary interlock switch and the interlock
monitor switch operate properly by opening
and closing the door several by opening and
closing the door several times.
(b) Make sure the perforated screen and the
dielectric choke of the door are correctly and
firmly mounted.
(2) After power is applied:
(a) Make sure the interlock switch mechanism is
operating properly by opening and closing
the door.
(b) Check microwave energy leakage must
bebelow the limit of 5 mW/cm
(All service adjustments should be made for
minimum microwave energy leakage
readings).
2
(3) Do not operate the unit until it is completely
repaired, if any of the following conditions exist.
The unit must not be operated.
(a) The door does not close firmly.
(b) The hinge is broken.
(c) The door seal is damaged.
(d) The door is bent or warped, or there is any
other visible damage on the unit that may
cause microwave energy leakage.
NOTE: Always keep the seal clean.
(e) Make sure that there are no defective parts
in the interlock mechanism.
(f) Make sure that there are no detective parts
in the microwave generating and transmission
assembly (especially waveguide).
(4) he following items should be checked after the
unit is repaired:
(a) The interlock monitor switch is connected
correctly and firmly.
(b) The magnetron gasket is properly positioned
and mounted.
(c) The waveguide and the oven cavity are
intact.(no microwave energy leakage)
(d) The door can be properly closed and the
safety switches work properly.
(e) The unit must stop when the door is opened or
the time is up.
The unit must not be operated with any of the above
components removed or by-passed.
7-1
MICROWAVE LEAKAGE TEST
CAUTIONS
• Be sure to check microwave leakage prior to
servicing the oven if the oven is operative prior to
servicing.
• The service personnel should inform the
manufacture importer, or assembler of any certified
oven unit found to have a microwave emission level
in excess of 5 mW/cm2and should repair any unit
found to have excessive emission levels at no cost to
the owner and should ascertain the cause of the
excessive leakage. The service personnel should
instruct the owner not to use the unit until the oven has
been brought into compliance.
• If the oven operates with the door open, the service
personnel should:
- Tell the user not to operate the oven.
• The service personnel should check all surface and
vent openings for microwave leakage.
• Check for microwave leakage after every servicing. The
power density of the microwave radiation leakage
emitted by the microwave oven should not exceed
4 mW/cm2. Always start measuring of an unknown field
to assure safety for operating personnel from radiation
leakage.
MEASURING MICROWAVE ENERGY
LEAKAGE
• Pour 275±15cc of 20±5°C(68±9°F) water in a beaker
which is graduated to 600 cc, and place the beaker
on the center of the turntable.
• Set the energy leakage monitor to 2,450 MHz and
use it following the manufacturer's recommended
test procedure to assure correct result.
• When measuring the leakage, always use the 2-inch
(5cm) spacer supplied with the probe.
• Operate the oven at its maximum output.
• Measure the microwave radiation using and
electromagnetic radiation monitor by holding the
probe perpendicular to the surface being measured.
Move probe along shaded area.
Probe scanning speed
Less than 2.5 cm/sec. ( 1 in/sec)
EQUIPMENT
• TESTER (VOLTS-DC, AC, Ohmmeter)
• Microwave survey meter
- Holaday HI-1500
HI-1501
- Narda 8100
8200
• 600 cc non conductive material beaker (glass or
plastic), inside diameter: approx. 8.5 cm (3
• Glass thermometer: 100°C or 212°F (1 deg scale)
1
/2 in.)
7-2
WATER LOAD
TURNTABLE
MEASUREMENT WITH THE OUTER CASE
REMOVED
(1) When you replace the magnetron, measure for
microwave energy leakage before the outer case
is installed and after all necessary components are
replaced or adjusted. Special care should be
taken in measuring the following parts.
- Around the magnetron
- The waveguide
WARNING: AVOID CONTACTING ANY HIGH
VOLTAGE PARTS.
MEASUREMENT WITH A FULLY
ASSEMBLED OVEN
(1) After all components, including the outer
panels, are fully assembled, measure for
microwave energy leakage around the door
viewing window, the exhaust opening and air
inlet openings.
(2) Microwave energy leakage must not exceed the
values prescribed below.
NOTE:
Leakage with the outer panels removed - less than
5 mW/cm
Leakage for a fully assembled oven (“Before the
latch switch (primary) is interrupted”) with the door
in a slightly opened position - less than 2 mW/cm2.
2
NOTE WHEN MEASURING
(1) Do not exceed meter full scale deflection.
(2) The test probe must be removed no faster than
1 inch/sec (2.5cm/sec) along the shaded area,
otherwise a false reading may result.
(3) The test probe must be held with the grip portion
of the handle. A false reading may result if the
operator hand is between the handle and the
probe.
(4) When testing near a corner of the door, keep
the probe perpendicular to the surface making
sure the probe horizontally along the oven
surface, this may possibly cause probe damage.
RECORD KEEPING AND NOTIFICATION
AFTER MEASUREMENT
(1) After adjustment and repair of any microwave
energy interruption or microwave energy blocking
device, record the measured values for future
reference. Also enter the information on the
service invoice.
(2) Should the microwave energy leakage not be
more than 2 mW/cm2after determining that all parts
are in good condition, functioning properly and
genuine replacement parts which are listed in this
manual have been used.
(3) At least once a year, have the electromagnetic
energy leakage monitor checked for calibration
by its manufacturer.
POWER OUTPUT MEASUREMENT
(1) Microwave power output measurement is made with
the microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting with
a load of (1000±5) g of potable water.
(2) The water is contained in a cylindrical borosilicate
glass vessel having a maximum material thickness of
1/8
”
(3 mm) and an outside diameter of approximately
”
(190mm).
7.6
(3) The oven and the empty vessel are at ambient
temperature prior to the start of the test.
(4) The initial temperature (T1) of the water is
(10±2)°C(50°F) It is measured immediately before the
water is added to the vessel. After addition of the water
to the vessel, the load is immediately placed on the
center of the turntable which is in the lowest position
and the microwave power switched on.
(5) The time T for the temperature of the water to rise by a
value ∆T of (10±2)°K is measured, where T is the time
in seconds and ∆T is the temperature rise. The initial
and final water temperatures are selected so that the
maximum difference between the final water
temperature and the ambient temperature is 5°K.
(6) The microwave power output P in watts is
calculated from the following formula :
P =
is measured while the microwave generator is
operating at full power. Magnetron filament heat-up
time is not included. (about 3 sec)
(7) The water is stirred to equalize temperature
throughout the vessel, prior to measuring the final
water temperature.
(8) Stirring devices and measuring instruments are
selected in order to minimize addition or removal of
heat.
4187 x (∆T)