BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
P/NO : 3828W5S5355
MV1610WW
November, 2005
Printed in Korea
CAUTION
SAFETY PRECAUTIONS
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE EXPOSURE
TO EXCESSIVE MICROWAVE ENERGY
a. Do not operate or allow the oven to be operated with the door open.
b. Make the following safety checks on all ovens to be serviced before activating the
magnetron or other microwave source, and make repairs as necessary; (1) Interlock
operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other
damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or
abuse.
c. Before turning on microwave power for any service test or inspection within the
microwave generating compartments, check the magnetron, wave guide or transmission
line, and cavity for proper alignment, integrity, and connections.
d. Any defective or misadjusted components in the interlock, monitor, door seal, and
microwave generation and transmission systems shall be repaired, replaced, or adjusted
by procedures described in this manual before the oven is released to the owner.
e. A Microwave leakage check to verify compliance with the Federal Performance Standard
should be performed on each oven prior to release to the owner.
• Proper operation of the microwave ovens requires that the magnetron be assembled to the wave
guide and cavity. Never operate the magnetron unless it is properly installed.
• Be sure that the magnetron gasket is properly installed around the dome of the tube whenever
installing the magnetron.
• Routine service safety procedures should be exercised at all times.
• Untrained personnel should not attempt service without a thorough review of the test procedures
and safety information contained in this manual.
FOREWORD
Read this Manual carefully. Failure to adhere to or observe the information in this Manual may result in exposing
yourself to the Microwave Energy normally contained within the oven cavity.
1500W maximum (Microwave oven+Cook top lamps+Ventilation fan)
1000W (IEC60705)
2450 MHz ± 50 MHz
120 VAC, 60 Hz
13 Amp. (Microwave oven+Cook top lamp+Ventilation fan)
Forced Air Cooling
Rectification Voltage Double Half-Wave
Choke System
Oven Cavity Thermostat:
Open at 90°C ± 5°C
Fuse(20A)
Primary Interlock Switch
Secondary Interlock Switch
Interlock Monitor
2M246-050GF
Capacitor: 1.0µF, 2.1 KV AC
Diode; 350mA, 9.0 KV
120 V, 30 W
120 V, 25 W
Digital, up to 99 mim. 99 sec. (in each cooking stage)
Tempered Safety Glass
2915/16"(W)x167/16"(H)x153/8"(D)
9
/16"(W)x83/4"(D)x14 1/8"(H)
21
1.6 Cu.ft.
Owner’s Manual & Cooking Guide, Installation Manual,
Exhaust Adapter, Exhaust Damper, Mounting Kit and Two
Filters, Rotating Ring Assembly.
1-1
CAUTIONS
Unlike other appliances, the microwave oven is
high-voltage and high-current equipment.
Though it is free from danger in ordinary use,
extreme care should be taken during repair.
• DO NOT operate on a 2-wire extension cord during
repair and use.
• NEVER TOUCH any oven components or wiring during
operation.
• BEFORE TOUCHING any parts of the oven, always
remove the power plug from the outlet.
• For about 30 seconds after the oven stops, an electric
charge remains in the high voltage capacitor. When
replacing or checking, you must discharge the high
voltage capacitor by shorting across the two terminals
with an insulated screwdriver.
MICROWAVE RADIATION
Personnel should not be exposed to the
microwave energy which may radiate from the
magnetron or other microwave generating
device if it is improperly used or connection.
All input and output microwave connections,
waveguide, flange, and gasket must be secure
never operate the device without a microwave
energy absorbing load attached.
Never look into an open waveguide or antenna
while the device is energized.
• Proper operation of the microwave oven requires that
the magnetron be assembled to the waveguide and
cavity. Never operate the magnetron unless it is
properly installed.
• Be sure that the magnetron gasket is properly
installed around the dome of the tube whenever
installing the magnetron.
• Remove your watches whenever working close to or
replacing the Magnetron.
• DO NOT touch any parts of the control panel circuit. A
resulting static electric discharge may damage this
P.C.B.
• NEVER operate the oven with no load.
• NEVER injure the door seal and front plate of the oven
cavity.
• NEVER put iron tools on the magnetron.
• NEVER put anything into the latch hole and the interlock
switches area.
ANTENNA
Gasket
COOLING FIN
MAGNETRON
CHASSIS GROUND
FILAMENT
TERMINALS
MAGNETRON
THE OVEN IS TO BE SERVICED ONLY
BY PROPERLY QUALIFIED SERVICE
PERSONNEL.
2-1
INSTALLATIONS
BEFORE YOU BEGIN, READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY.
PRECAUTIONS ON INSTALLATION
A. Plug the power supply cord into a 120V AC, 60Hz,
single-phase power source with a capacity of 15A
or 20A.
B. Avoid placing the unit in a location where there is
direct heat or splashing water.
C. Install the unit on the mounting plate firmly.
D. Place the unit as far away as possible from TV,
radio, etc. to prevent interference.
GROUNDING INSTRUCTIONS
For personal safety, this appliance must be fully
grounded at all times.
In the event of an electrical short circuit, grounding
reduces the risk of electrical shock.
The plug must be plugged into an outlet that is
properly installed and grounded.
CAUTION
This unit is equipped with a 3-prong plug for your
safety. If the wall outlet is a grounded 3-hole type,
the unit will be grounded automatically.
Plug with Ground
Prong
Properly Polarized
and Grounded
Outlet
WARNING
Improper use of the grounding plug can result in
a risk of electric shock.
Do not, under any circumstances, cut or remove
the third ground prong from the power cord plug.
3-1
OPERATING INSTRUCTIONS
CONTROL PANEL
NOTE: Styling and features vary by model.
4-1
CONTROL PANEL INSTRUCTIONS
NOTE: Styling and features vary by model.
1. DISPLAY: The Display includes a clock and
indicators to tell you time of day, cooking time
settings and cooking functions selected.
2. POPCORN: Touch this pad when popping popcorn
in your microwave oven.
3. POTATO: Touch this pad to cook potatoes from
1 to 4.
4. BEVERAGE: Touch this pad to reheat one cup or
two cups a beverage.
5. PIZZA: Touch this pad to reheat 1 to 3 slices.
6. REHEAT: Touch this pad to reheat dinner plate
soup/sauce, casserole, roll/muffin.
7. FROZEN ENTREE: Touch this pad to cook frozen
entrees by choosing a preset weight.
8. AUTO COOK: Touch this pad to cook vegetables,
rice, or casseroles.
9. TIME DEFROST: Touch this pad to set a defrost
time.
10. AUTO DEFROST: Meat, poultry, fish. Touch this
pad to select food type and defrost food by weight.
11. NUMBER: Touch number pads to enter cooking
time, power level, quantities or weights.
12. KITCHEN TIMER: Touch this pad to set the kitchen
timer.
13. CLOCK: Touch this pad to enter the time of day.
14. EZ ON: Touch this pad to set and start quickly at
100% power level.
15. TIME COOK: Touch this pad to set a cooking time.
16. POWER LEVEL: Touch this pad to select a
cooking power level.
17. STOP/CLEAR: Touch this pad to stop the oven or
clear all entries.
18. START: Touch this pad to start a function or enter
all entries. If you open the door after oven begins
to cook, touch START again.
19. FAN HI/LO/OFF: Touch this pad to turn the fan on or
off.
20. LIGHT HI/LO/OFF: Touch this pad to turn the
cooktop lamp on or off.
4-2
OVERALL CIRCUIT DIAGRAM
SCHEMATIC DIAGRAM
5-1
MATRIX CIRCUIT FOR TOUCH KEY BOARD
5-2
GENERAL INFORMATION FOR SERVICE
GENERAL PRECAUTIONS IN USE
A. Never operate the unit when it is empty.
Operating the oven with no load may shorten the
life of the magnetron. Whenever cooking dry foods
(dried fish, bread, etc.) or a small amount of food,
be sure to put a glass of water into the cooking
compartment. The glass turntable may become hot
after operating, be careful when touching it.
B. Aluminum foil should be avoided because it will
disrupt cooking and may cause arcing. However,
small pieces may be used to cover some parts of
food to slow the cooking. Any aluminum foil used
should never be closer than 2.5 cm to any side wall
of the oven.
TRIAL OPERATION
After installation, the following sequences and results
should be checked carefully.
A. Put a container filled with water (about 1 liter) into
the oven, and close the door tightly.
B. Set cooking time for 10 minutes by touching “1” and
then “0” three times. “1, 0, 0, 0” appears in the
display window.
C. Touch the START key.
Make sure the cavity light comes on. The unit will
begin cooking and the display window will show the
time counting down by seconds.
D. After about 5 minutes, make sure the primary
interlock switch, the secondary interlock switch and
the interlock monitor switch operate properly by
opening and closing the door several times. Touch
the START key each time the door is closed.
E. Continue operating the unit. Four long beep sound
signal is heard when the time is up. The unit will
shut off automatically.
F. Confirm the water is hot.
G. Finally, measure the output power according to
“POWER OUTPUT MEASUREMENT” on
page 7-3.
FEATURES AND SPECIFICATIONS
FEATURES
A. The safety systems incorporated in this model are:
(Note: This thermostat located on the oven
cavity will open and stop the unit from operation
only if a high temperature is reached, such as,
a fire created by overcooking food.)
B. Any one of 10 power output levels ranging 100W to
1000W can be selected by the touch control and
electronic computer system.
6-1
SERVICE INFORMATION
PRECAUTIONS AND REPAIR SERVICE TIPS
PRELIMINARY
A. SINCE NEARLY 2,100 VOLTS EXISTS IN SOME
CIRCUITS OF THIS UNIT REPAIRS SHOULD BE
CARRIED OUT WITH GREAT CARE.
The filament leads of magnetron carry High Voltage
with respect to ground. Extreme caution must be
exercised. Never plug the unit into a power source
to determine which component is defective in high
voltage section.
B. TO AVOID POSSIBLE EXPOSURE TO
MICROWAVE ENERGY LEAKAGE, THE
FOLLOWING PRECAUTIONS MUST BE TAKEN
BEFORE SERVICING.
(1) Before the power is applied:
(a) Make sure the primary interlock switch, the
secondary interlock switch and the interlock
monitor switch operate properly by opening and
closing the door several by opening and closing
the door several times.
(b) Make sure the perforated screen and the
dielectric choke of the door are correctly and
firmly mounted.
(2) After power is applied:
(a) Make sure the interlock switch mechanism is
operating properly by opening and closing the
door.
(b) Check microwave energy leakage must
bebelow the limit of 5 mW/cm2.
(All service adjustments should be made for
minimum microwave energy leakage readings).
(3) Do not operate the unit until it is completely
repaired, if any of the following conditions exist.
The unit must not be operated.
(a) The door does not close firmly.
(b) The hinge is broken.
(c) The door seal is damaged.
(d) The door is bent or warped, or there is any
other visible damage on the unit that may
cause microwave energy leakage.
NOTE: Always keep the seal clean.
(e) Make sure that there are no defective parts in
the interlock mechanism.
(f) Make sure that there are no detective parts in
the microwave generating and transmission
assembly (especially waveguide).
(4) The following items should be checked after the
unit is repaired:
(a) The interlock monitor switch is connected
correctly and firmly.
(b) The magnetron gasket is properly positioned
and mounted.
(c) The waveguide and the oven cavity are intact.
(no microwave energy leakage)
(d) The door can be properly closed and the
safety switches work properly.
(e) The unit must stop when the door is opened or
the time is up.
The unit must not be operated with any of the above
components removed or by-passed.
7-1
MICROWAVE LEAKAGE TEST
CAUTIONS
• Be sure to check microwave leakage prior to
servicing the oven if the oven is operative prior
to servicing.
• The service personnel should inform the
manufacture importer, or assembler of any
certified oven unit found to have a microwave
emission level in excess of 5 mW/cm2and should
repair any unit found to have excessive emission
levels at no cost to the owner and should ascertain
the cause of the excessive leakage. The service
personnel should instruct the owner not to use the
unit until the oven has been brought into compliance.
• If the oven operates with the door open, the
service personnel should:
- Tell the user not to operate the oven.
- Contact the manufacturer and CDRH
(Center for Devices and Radiological Health)
immediately.
NOTE: Address on CDRH
Office of Compliance(HFZ-312)
Center for Devices and Radiological
Healthe 1390, Piccard Drive,
Rockville. MD 20850
• The service personnel should check all surface and
vent openings for microwave leakage.
• Check for microwave leakage after every servicing.
The power density of the microwave radiation
leakage emitted by the microwave oven should not
exceed 4 mW/cm2. Always start measuring of an
unknown field to assure safety for operating
personnel from radiation leakage.
MEASURING MICROWAVE ENERGY
LEAKAGE
• Pour 275±15cc of 20±5°C(68±9°F) water in a
beaker which is graduated to 600 cc, and place
the beaker on the center of the turntable.
• Set the energy leakage monitor to 2,450 MHz and
use it following the manufacturer's recommended
test procedure to assure correct result.
• When measuring the leakage, always use the 2inch (5cm) spacer supplied with the probe.
• Operate the oven at its maximum output.
• Measure the microwave radiation using and
electromagnetic radiation monitor by holding the
probe perpendicular to the surface being
measured.
Move probe along shaded area.
Probe scanning speed
Less than 2.5 cm/sec. ( 1 in/sec)
EQUIPMENT
• TESTER (VOLTS-DC, AC, Ohmmeter)
• Microwave survey meter
- Holaday HI-1500
HI-1501
- Narda 8100
8200
• 600 cc non conductive material beaker (glass or
plastic), inside diameter: approx. 8.5 cm (3 1/2in.)
• Glass thermometer: 100°C or 212°F (1 deg scale)
7-2
Loading...