Glow-worm icon 23t, icon 28t User, Installation And Servicing Instructions

This is a CAT II2H3+
appliance
USER, INSTALLATION
AND SERVICING
INSTRUCTIONS
Wall hung combination boilers
2
icon
Index
Note
The boiler serial number is marked on the data label attached to the inside of the outer casing. Refer to the ‘Introduction’ section for a description of the basic functions of the boiler . The ‘User’ section describes how to safely operate the boiler.
Mandatory warning for CEE countries
WARNING, these appliances were designed, approved and inspected to meet the
requirements of the English market. The identification plate located on the inside of the appliance certifies the origin where the product was manufactured and the country for which it is intended.
If you see any exception to this rule, please contact your nearest Stockist. Thank you in advance for your assistance.
Index
Introduction .......................................... 3
User
instructions ..................................3
Introduction .......................................... 4
Controls and lighting............................. 4
Technical data ..............................7
Installation
instructions ................................ 11
Clearances ......................................... 11
Terminal position ................................ 12
Heating system design....................... 13
Domestic hot water system design..... 13
Boiler connections .............................. 14
Gas connection .................................. 14
Boiler installation ................................ 15
Horizontal flue installation .................. 16
Vertical flue installation....................... 17
Flue configuration ............................... 18
Electrical connection .......................... 19
Commissioning................................... 20
Safety devices .................................... 22
Gas valve setting................................ 23
Adjustments ....................................... 23
Boiler schematic................................. 25
Servicing
instructions ................................26
Routine cleaning and inspection......... 27
Replacement of parts ......................... 28
Schematic wiring diagram .................. 31
3
icon
User instructions
Introduction
The icon 23 t and icon 28 t boilers are wall mounted combination boilers providing central heating and instantaneous domestic hot water.
The boilers are of the II2H3+ category for use with Natural gas (G20) as distributed in the United Kingdom.
These instructions should be carefully followed for the safe and economical use of your boiler. The boiler has a fan assisted balanced flue which both discharges the product of combustion to,
and draws the combustion air from the outside of the building.
ACCESSORIES
A range of accessories are available including vertical flue components. For further information, contact you nearest Stockist.
GAS SAFETY (INSTALLATION AND USE) REGULATIONS
In your interests and that of gas safety, it is the law that ALL gas appliances are installed and serviced by a competent person in accordance with the above regulations.
GAS LEAK OR F AULT
If a gas leak or fault exists or is suspected, turn the boiler off and consult the local gas company or your Installer/Service Provider.
BOILER CONTROLS
The control panel, located at the lower front of the boiler , allows the boiler to be started, shut down, controlled and monitored during use, refer to ‘User Instructions’.
User
instructions
4
icon
User instructions
Introduction
The icon 23 t and icon 28 t boilers are wall mounted combination boilers providing central heating and instantaneous domestic hot water.
These instructions should be carefully followed for the safe and economical use of your boiler .
GAS LEAK OR F AULT
If a gas leak or fault exists or is suspected, turn the boiler off and consult the local gas company or your Installer/Service provider.
IN CASE OF POWER SUPPLY F AILURE
The boiler no longer operates. As soon as power supply is restored, the boiler will restart automatically.
IN CASE OF LOSS OF W ATER IN THE SYSTEM CAUTION: The boiler is installed as part of a sealed system which must only be drained and
filled by a competent person.
If the pressure shown on the pressure gauge is less than 1 bar the system must be filled up immediately.
Important notice: A central heating system cannot operate satisfactorily unless it is properly filled with water and unless the air initially contained in the piping systems has been properly bled off. If these conditions are not satisfied, air noise will occur within the system.
AIR IN THE HEATING SYSTEM
Persistent air in the heating system may indicate leaks in the system or corrosion taking place. Call your Installer/Service provider.
OVERHEATING SAFETY
In the event of problem, the overheat safety device causes safety shutdown of the boiler. If this happens, call your In­staller/Service provider.
Controls and lighting
The control panel, located at the lower front of the boiler casing, see diagram, allows the boiler to be started, shut down, controlled and monitored during use.
Make sure that: — The boiler is connected to the electrical supply. — The boiler gas service cock is open. — The pressure gauge reads between 1 and 2 bar . The boiler is now ready to start.
5
icon
User instructions
Controls
1 Safety lockout light 2 Summer/Winter switch 3 Heating temperature control 4 Hot water temperature control 5 Pressure gauge 6 Timeclock 7 Plastic toggles
TO START THE BOILER
Turn selector (2) to the desired Summer
or Winter position.
The green lamp
will light.
TO STOP THE BOILER
Turn selector (2) to the OFF position (0). If the boiler is to be out of operation for a long period, turn off the gas service cock.
SETTING TO ‘SUMMER’ MODE (HOT W ATER ONLY)
Turn selector (2) to the Summer position
.
Adjust the domestic hot water control
(4) to the desired hot water temperature. The boiler will
operate according to the system requirements.
SETTING TO ‘WINTER’ MODE (HEATING AND HOT WATER)
Turn selector (2) to the Winter position
.
Adjust the heating temperature control
(3) to the desired temperature.
Adjust the domestic hot water control
(4) to the desired hot water temperature. The heating will operate according to the requirements of the timeclock and room thermostat if fitted or, will operate according to the system requirements.
Domestic hot water always has priority over central heating.
TO PROGRAM DAIL Y TIMECLOCK (6) (WINTER MODE ONLY)
Set the current time, by turning the dial clockwise until the current time is shown against the indicator “
”. Push in plastic toggles (7) against the time you wish the heating to come on. The timeclock can operate in three positions: automatic “
”, heating off “0”, and heating on “1”.
To select, move the lever to the desired position.
NOTE: In case of failure of electrical supply, timeclock does not operate, having no back-up bat-
tery . Therefore it will be necessary to adjust the current time, once electrical supply is restored.
6
icon
User instructions
SAFETY LOCKOUT
If, for any reason, the boiler does not operate, check if lockout lamp
(1) is lit. If so, turn selector (2) to the reset position . The selector is spring loaded and automatically returns to its’ previous position when released.
Note: This lamp will only light if the boiler has locked out and there is a hot water or central heating
demand at that particular time.
IMPORT ANT: If the safety lockout lamp lights frequently, contact your Installer/Service Pro­vider.
DRAINING AND FILLING CAUTION: The boiler is installed as part of a sealed system which must only be drained and
filled by a competent person.
Note: If there is persistent loss of system pressure, you must consult your Installer/Service Pro-
vider.
HEA TING SAFETY VALVE CAUTION: A safety valve with a discharge pipe is fitted to this boiler.
The valve MUST NOT BE TOUCHED except by a competent person. If the valve discharges at any time, switch the boiler off and isolate it from the electrical supply. Contact your Installer/Service Provider.
SERVICING/MAINTENANCE
To ensure the continued efficient and safe operation of the boiler, it is recommended that it is checked and serviced at regular intervals. The frequency of servicing will depend upon the instal­lation conditions and usage but, in general, once a year should be enough.
CLEANING
The boiler casing can be cleaned with a damp cloth followed by a dry cloth to polish. Do not use abrasive or solvent cleaners.
BOILER CASING CAUTION: Do not remove or adjust the casing in any way , as incorrect fitting may result in
faulty operation.
If in doubt, contact your Installer/Service Provider.
7
icon
T echnical data
Technical
data
8
icon
T echnical data
ATADLACINHCETtinU
t32nocit82noci
noitacifitreCEn7424TA36005992LB4960
ssalC +3H2II
epyT 28-26-25-24-23-21C
epyTsaG 02G
)sH(tupnItaeH.xaMWk4.8253
)sH(tupnItaeH.niMWk6.1151
)iH(tuptuOtaeH.xaMWk3.321.82
)iH(tuptuOtaeH.niMWk7.811
YCNEICIFFE
ycneiciffelanimoN%293.29
daol%03taycneiciffE%4.7809
GNITAEH
egnarerutarepmeTC°58-0458-04
lessevnoisnapxEl68
erusserplessevnoisnapxErab1 1
erusserpgnikrow.xaMrab5.25.2
erutarepmetmetsys.xaMC°5858
RETAWTOH
esirerutarepmetC°53taetarwolFnim/l6.95,11
wolfretaw.niMnim/l5.25.2
erusserpylppus.xaMrab6 6
erusserpylppus.niMrab4.04.0
egnarerutarepmeTC°56-5356-53
ATADLACIRTCELE
ycneuqerf/egatloVzH/V05/03205/032
rewoPW051071
noitcetorpfoleveLPI4444
SNOISNEMID
htdiWmm004054
thgieHmm007007
htpeDmm003033
)tfil(thgieWgk5324
SNOITCENNOC
nruter/wolfgnitaeHmmmm22mm22
teltuo/telniretaWcitsemoDmmmm51mm51
saGmmmm51mm51
Øtelniria/teltuostcudorpeulFmm001/06001/06
xam/nimhtgneleulflatnoziroHm3-13-1
xam/nimhtgneleulflacitreVm4-14-1
ERUSSERPYLPPUSSAG
erusserplanimoNrabm0202
retemaidsrotcejnImmØ2.12.1
NOITPMUSNOCSAG
xamQh/cm7.282.3
nimQh/cm1.14.1
9
icon
T echnical data
t82noci
TUPTUOTAEHERUSSERP
Wkrh/utBrabm
)nim(2.9093136.2
01021438.2 11235733
21449042.3
31653446.3
41867742.4
51081155
61295456.5
71400852.6
81614167
91828466.7
02042863.8
12256179
22460575.9
32674871.01
42888188.01
520035821
62217885.21
)xam(7.82429792.31
t32noci
TUPTUOTAEHERUSSERP
Wkrh/utBrabm
)nim(7.8486926.1
01021433.2
11235737.2
21449044.3
31653447.3
41867745.4 51081155
61295455.5
71400851.6
81614165.6
91828462.7
02042868
12256176.8
224605701
)xam(3.32005978.11
+
; <
4
/
3
relioB
L
)mm(
H
)mm(
P
)mm(
X
)mm(
Y
)mm(
Q
)mm( t32noci004007003702391741 t82noci054007033752391061
1teltuostcudorpeulF
2telniriA
DIMENSIONS CONNECTIONS FOR FLUE
10
icon
T echnical data
HEATING
DOMESTIC
WATER
GAS
BOILER SCHEMATIC
1 By-pass 2 Pump 3 Drain valve 4 Expansion vessel 5 Gas valve 6 Burner 7 Primary heat exchanger 8 Flue hood 9 Air pressure switch 10 Automatic air vent 11 Fan 12 Loss of water switch 13 Heating system safety valve 3 bar 14 Hydraulic 3-way valve 15 Domestic heat exchanger 16 Water valve
RETURN
FLOW
OUTLET
INLET
AVAILABLE PUMP CAPACITY
1–icon 23 t (Automatic By-Pass) 2–icon 28 t (Automatic By-Pass)
Water flow l/h
Pressure m. H
2
O