Introduction
~.
These instructions should be read and carefully followed for the safe and economical use of your boiler.
The Economy Plus range are boilers designed to provide central heating and indirect domestic hot water from a fully pumped system with a fully indirect cylinder.
Important Notice
This boiler is for use on natural gas only and cannot be used on any other gas.
Gas Safety (Installation and Use)
Regulations.
In your interest and that of gas safety it is the Law that ALL gas appliances are installed by a competent person in accordance with the current issue of the above regulations.
Gas Leak or Fault
If a gas leak or fault exists or is suspected, the BOILER MUST BE TURNED OFF, including the electrical supply and MUST NOT BE USED UNTIL THE FAULT HAS BEEN PUT RIGHT.
Advice/help should be obtained from your installation/servicing company or the local gas undertaking.
Maintenance/Servicing
To ensure the continued efficient and safe operation of the boiler it is recommended that it is checked and serviced as necessary at regular intervals.
The frequency of servicing will depend upon the particular installation conditions and usage, but in general once a year, preferably at the end of the heating season, should be enough.
It is the Law that any servicing must be carried out by a competent person.
Hepworth Heating Ltd., Nottingham Road, 8elper, Derby. DE5 1JT Tel: 8elper (0773) 824141 Telex 37586
Technical Services Department: Telephone Belper (0773) 828100
3957
Boiler Clearances
If fixtures are positioned close to the boiler space must be left as shown in diagram 1. Enough space must also be left in front of the boiler to allow for servicing.
Boilers Installed in a Compartment or Cupboard
If the boiler is installed in a cupboard or compartment do not obstruct any ventilation openings.
Do not use the cupboard. or compartment for storage.
Regularly make sure that the air vent openings are clear of obstructions.
Cleaning
Caution. This appliance contains metal parts (components) and care should be taken when handling and cleaning, with particular regard to edges.
Clean the casing occasionally by wiping it over with a damp soapy cloth or dry polishing duster.
Do not use an abrasive cleaner.
Boiler Electrical Supply
WARNING. The boiler must be earthed. The boiler must only be connected to a 240V-50Hz
supply, protected by a 3A fuse. All wiring must be in accordance with the current
issue of the I.E.E. Wiring Regulations. The colours of three core flexible cable are: Brown - live, blue - neutral, green/yellow - earth. As the markings on your plug may not correspond
with these colours, proceed as follows, The wire coloured blue must be connected to the
terminal marked "N" or "Black". The wire coloured brown must be connected to the
terminal marked "L" or "Red". The wire coloured green/yellow must be connected
to the plug terminal marked "E" or "Green" or the earth symbol
*.
220161
MINIMUM CLEARANCES
A
500·
B
78
C
*
0
10
E
5
To
a permanent surface.
*SIDE FLUE - 220mm *REAR FLUE - 120mm
CLEARANCES Diagram 1
Electrical Supply Failure
Failure of the electrical supply will cause the burner to go out. Should this happen, operation of the appliance will normally resume after the electrical supply is restored.
If the burner does not relight after an electrical s~pply failure the overheat device may need resetting, refer to diagram 2, remove the controls tray and press the reset button.
If the cutoff occurs again, turn the appliance off and contact your installation/servicing company.