Glow-worm Clearly Solar Horizontal On-Roof Collector User Manual

Page 1
Clearly Solar
Solar Thermal Flat Plate Collector
Installation Instructions
Horizontal On-roof mounting
15°- 75°
SRH 2.3
www.glow-worm.co.uk
1
Page 2
These Clearly Solar Flat Plate collectors come with a comprehensive manufacturer’s guarantee.
Details of the guarantee, and the terms and conditions that apply can be found on the Guarantee
registration card. We recommend you complete and return this as soon as possible.
Customer Service:
01773 596510
Technical Helpline:
01773 828300
General and Sales enquiries:
Tel. 01773 824639
Fax: 01773 820569
To register your Glow-worm appliance call:
0800 0732142
Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer’s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future reference. Installers are required to carry out installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hotwater Industry Council who manage and promote the Scheme. Visit www.centralheating.co.uk for more information.
2
Page 3
These instructions must be handed to the user on completion of the installation.
CONTENTS DESCRIPTION SECTION PAGE
Warnings 4
GENERAL
INFORMATION
Important Information 4 Statutory Requirements 5
TECHNICAL
SPECIFICATION
ROOF MOUNTING
Technical Specication 1 6
Technical Data 2 7
Solar Collector and Hydraulic Connection Arrangement 3 8 Hydraulic Connection Kits 4 9 Roof Anchor - Type P 5 10 Roof Anchor - Type S 6 12 On-Roof Installation 7 13
3
Page 4
WARNINGS
Metal Parts
This solar panel contains metal parts (components) and care should be taken when handling,
with particular regard to edges.
Risk of death from falls and falling objects
Observe the national regulations for working at heights.
Danger of burning and scalding
In case of solar irradiation inside the units, solar panels can reach 200°C.
Remove the sun protection lm installed at the factory only after the solar energy system has been started up.
Sealed Components
Under no circumstances must the user interfere with or adjust sealed parts.
Important Information
General
These instructions must be handed to the user on completion of the installation. This installation instruction applies exclusively to the on-roof mounting of the Clearly Solar, solar collector panel. The solar collector panel is one component in a solar system and it is recommended that you read all other component(s) literature prior to installation. We accept no liability for any damage caused by failure to observe these instructions.
Manual Handling
With regards to the “Manual Handling Operations, 1992 Regulations”, this product exceeds the recommended weight for a one man lift. Recommend 2 person lift. Ensure safe lifting techniques are used – keep back straight – bend using legs. Keep load as close to body as possible. Ensure co-ordinated movements during lift. Clear the route before attempting the lift. If removing from truck straddle the load and tilt forwards to facilitate secure grip. Do not twist – reposition feet instead. Take care to avoid trip hazards, slippery or wet surfaces and when climbing steps or ladders. Always use assistance if required. Installation of the solar collector panel will require a risk assessment.
Damage from lightning
If the installation height is more than 20m or if the solar panels are projected above the roof ridge, electro-conductive components must be connected to a lightning protection device.
Frost Protection
Under no circumstances should water be in the solar collector panel if there is a danger of frost.
After pressurisation and ushing, the solar collectors panels
may contain water residues.
Immediately ll the solar system with solar uid. Check the uid concentration with a frost protection tester. Water remaining in the solar circuit may dilute the uid.
Testing and Certication
This solar collector panel is tested and certicated for safety
and performance. It is, therefore, important that no alteration is made, without permission, in writing, by Glow-worm. Any alteration not approved by Glow-worm, could invalidate
the certication, warranty and may also infringe the current
issue of the statutory requirements.
CE Mark
The CE mark on the solar collector panel indicates that it complies with the basic requirements of the applicable directives as stated on the data badge.
4
Page 5
Statutory Requirements
IMPORTANT
Where no British Standards exists, materials and equipment
should be t for their purpose and of suitable quality and
workmanship.
The installation of this solar collector panel must be carried out by a competent person in accordance the rules in force in the countries of destination. Manufacturer’s instructions must not be taken as overriding statutory requirements.
Statutory Requirements
In GB, the installation of the solar collector panel must comply with the requirements of the current issue of the following regulations: The manufacturer’s instructions supplied. The appropriate Buildings Regulations either The Building Regulations, The Building Regulations (Scotland),The Building Regulations (Northern Ireland). Working at Heights Regulations 2005. Connecting thermal solar appliances. Lightning protection requirements. Equipotential bonding of electrical installations. The Health and Safety at Work Act Control of Substances Hazardous to Health (COSHH). The Current I.E.E. Wiring Regulations.
The Water Supply (water ttings) Regulations 1999 or the
Water Byelaws 2000 (Scotland).
Where no specic instructions are given, reference should be
made to the relevant British Standard Code of Practice.
Regulations for the prevention of accidents
At all times follow the national regulations on working at heights. Make sure there is suitable safety equipment such as scaffolding or protective walls to prevent falling from roofs. Fall protection systems such as the Glow-worm fall protection system (item no. 0020054985) also has a fall arresting device if the roof scaffold and protective roof wall are inappropriate
for the specic task.
Only use tools and equipment such as lifting gear or ladders in accordance with the lifting regulations.
Cordon off areas below the working area sufciently to protect
people from falling objects. Mark the working area, for example with warning signs as described by the national regulations.
5
Page 6
1 Technical Specication
Design Description
The Clearly Solar, solar at plate collector, collects the
available solar radiation and transfers the heat through the
solar uid to be utilised by the system.
It has been designed to compliment the complete range of Glow-worm solar system components. The kits are suitable for roof pitches between 15°- 75°, please choose from the table below.
The solar thermal at plate collector includes a saltwater-
resistant aluminium frame as well as a copper surface absorber with a high selective coating.
The at plate collector has a CFC-free, standstill temperature-
resistant mineral wool insulation for long-life and excellent heat insulation. Hydraulic connections are tool free with double ‘O’ ring
sealing. The sensor sleeve is integrated into the hydraulic ow
connection.
The following kits are available and dependant upon the number of collectors, the quantities required are listed in the following tables and illustrated in the appropriate sections:-
On-roof installation components
High profile tiled roof (pantile)
Number of collectors
Type P anchor part no. 0020060302 - Section 5
Easy fit hydraulic connection set part no. 0020060207
Easy fit hydraulic extension set part no. 0020055175
Collector panel 1 2 3 4 5 6 7 8 9 10
Low profile tiled roof (slate)
Number of collectors
Type S anchor part no. 0020055184 - Section 6
Easy fit hydraulic connection set part no. 0020060207
Easy fit hydraulic extension set part no. 0020055175
Collector panel 1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 1 1 1 1 1 1 1 1 1
- 1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 1 1 1 1 1 1 1 1 1
- 1 2 3 4 5 6 7 8 9
1.1 On-roof mounting
With on-roof mounting, at collectors are fastened to
horizontal mounting rails quickly and reliably with attachment
clips. To ensure compatibility with different roongs, two
different roof anchors are available:
- Type P for high prole (pantile)
- Type S for at prole (slate) and extremely high protruding
tiles (e.g. Mediterranean clay tiles).
6
Page 7
2 Technical Data
80
1233
79
1075
79
2033
1978
14921
1178
Horizontal Collector
Diagram 2.1
Appliance designation Unit. Clearly Solar
Absorber type Serpentine
Gross area m
Aperture surface area m
Absorber surface area m
2
2
2
2.51
2.35
2.33
Absorber Aluminium (vacuum coated) 0.5 x 1178 x 1978
Dimensions (L x W x H) mm 1233 x 2033 x 80
Weight (Dry) kg 38
Fluid content l 2.16
Copper pipe connection, at-face Ø mm G 3/4" (DN16)
Insulation thickness mm 40
Max. operating pressure bar 10
Glass type Solar safety glass (prismatic structure)
Glass covering mm 3.2 (thickness) x 2033 x 1233
Coating High selective (blue)
Solar safety glass transmission t (dew)
Absorber emission ε (epsilon)
%
t = 91
% 5 ± 2
α = 95% ε = 5%
Back wall insulation mm, W/mk, kg/m 95 ± 2
Stagnation temperature °C 210
Efciency η
0
% 80
Heat capacity Ws/ (m•K) 5014
2
Efciency coefcient k1 W/(m
Efciency coefcient k2 W/(m
•K) 3.7
2
•K2) 0,012
7
Page 8
3 Solar Collector and Hydraulic Connection Arrangement
Solar Collector
The recommended collector arrangements are shown below.
1-5 Collectors
THE HYDRAULIC FLOW CAN BE DIAGONAL OR TOP AND BOTTOM
1
...
6 and up to 10 max Collectors
THE HYDRAULIC FLOW MUST BE DIAGONAL
1
...
Hydraulic Connections
It is recommended that the hydraulic connections should be made as shown below.
15045
4 5
9 10
Diagram 3.2
8
Page 9
4 Hydraulic Connection Kits
5
15188
5
4
3
1
5
6
2
7
Easy fit hydraulic connection set - Kit No. 0020060207
Part Description Qty.
1 Upper supply (with probe) 1
2 Return (inlet) 1
3 Lower plug 1
4 Upper plug (with ventilation) 1
5 Securing clip 4
Easy fit hydraulic extension set - Kit No. 0020055175
Part Description Qty.
6 Pipe coupling 2
7 Securing clip 4
9
7
Diagram 4.1
Page 10
5 Roof Anchor - Type P
Distance in milimetres
A 1233
B 200 - 300
C 1433 - 1633
15186
74
A
BB
CCB
B
Diagram 5.1
15153
COLLECTOR CLAMP
1233
BOTTOM PLATE SECURING SCREW
COLLECTOR CLAMP
*120
*120
SECURING SCREW
15408
*120
*120
ROOF ANCHOR TYPE P
* Total adjustment of collector clamp can
be 240mm to suit site conditions and reduce the need to cut tiles
Diagram 5.2
10
Page 11
5 Roof Anchor - Type P
IMPORTANT
● With due regard to the complete weight of the solar
collector system, (refer to technical data) ensure the roof rafters and battens are in good condition and have
sufcient load carrying capacity and the battens are
secure.
5.1 Fixing roof anchor type P
Remove the roof tiles to expose the roof battens and rafters where required, please refer to diagram 5.1 and 5.2 for position of brackets. If required loosen the securing screw, see diagram 5.2. Using a 5mm Allen key, release the bottom plate securing screw and swivel 180o and secure.
Position the roof anchor on the rafter, see diagram 5.3. Ensure that the roof anchor is secured to the rafter with the screws supplied. Re-position the tiles ensuring that the roof is water tight before
tting the collector.
Diagram 5.3
15405
11
Page 12
6 Roof Anchor - Type S
IMPORTANT
● With due regard to the complete weight of the solar
collector system, (refer to technical data) ensure the roof rafters and battens are in good condition and have
sufcient load carrying capacity and the battens are
secure.
6.1 Roof anchor type S
Refer to diagram 6.1.
Remove the tiles where required, refer to diagram 5.1.
The roof anchor must be secured to a rafter. Ensure that the roof anchor is secured with the screws supplied.
Slide the tiles back to their original position.
15162
Diagram 6.1
12
Page 13
7 On-Roof Installation
7.1 Collector installation
Ensure the mounting brackets are level before securing, see diagram 7.1.
15177
Position the collector, protective side uppermost, on the mounting bracket and beneath the clamp, see diagram 7.2. NOTE: The design is symmetrical and does not have a top or bottom.
IMPORTANT: Do not remove the protective lm until the
system is to be commissioned
Move the clamp into position ensuring the correct engagement of both clamps onto the collector.
Secure the clamps.
MOUNTING BRACKET
STRAIGHT EDGE
COLLECTOR CLAMP (UPPER)
Diagram 7.1
15178
MOUNTING BRACKET
Diagram 7.2
13
Page 14
7 On-Roof Installation
Insert the pipe couplings up to the limit stop into the corresponding openings on the side of the collectors, see diagram 7.3.
Secure the pipe coupling with the securing clip
Place the next collector on the lower mounting bracket. Slide
the collector up to the rst collector paying attention to the
pipe couplings, see diagram 7.4.
When fully inserted to the limit stops, ensure that the pipe couplings are secured with the securing clips.
15180
PIPE COUPLING
PIPE COUPLING
SECURING CLIP
Diagram 7.3
SECURING CLIP
15168
Diagram 7.4
14
Page 15
7 On-Roof Installation
With regards to the hydraulic system you have chosen, insert and secure the hydraulic connections, see diagrams 7.5 and
7.6.
Connect the collector Flow and Return to the system circuit.
Ensure that all of the following steps have been performed:-
- All the connections have been xed with securing clips.
- All hydraulic connections laid properly.
- The collector sensor has been connected.
- The collectors are connected to a lightning protection device.
- A pressure test carried out and all connections are tight.
- All insulation is intact.
NOTE: After initial commissioning and according to the season, high outside temperature oscillations can cause condensation in the collector, this is normal.
15181
1 - 5 Collectors
COLLECTOR SENSOR
COLLECTOR SENSOR
Diagram 7.5
15182
6 or more Collectors
15
Diagram 7.6
Page 16
0020080932-02 03.09
Because of our constant endeavour for improvement, details
may vary slightly from those shown in these instructions.
Glow-worm, Nottingham Road, Belper, Derbyshire. DE56 1JT
16
Loading...