globalindustrial.ca
Distribucion Industrial Globales S DE RL DE CF
User's manual Manual del usuario Manuel de l'utilisateur
Customer Service
US: 1-800-645-2986
Open and Closed Head Drum Lifter
Servicio de atención al Cliente
México: 01.800.681.6940
Model 988868
General Safety Information
WARNING:
The Drum Lifter is intended for specific
functions. Please adhere to the following
instructions to ensure safe and proper use.
• This drum lifter is designed for lifting drums in
vertical position only.
• The drum must have a top lip.
• Maximum capacity — 1000 Lbs. Do not exceed
rated capacity. Injury to person or property may
result from overloading, misuse, or carelessness.
• Inspect the drum lifter before each use. If there is
damage or distortion to any part, the drum lifter
must be removed from service until it is repaired
or replaced.
• Make sure the drum is secured by the lifting arms
before lifting.
• Suitable for use with standard steel or poly drums
with at least 3/16 inches chime.
• Lifting arms are adjustable to work with most 55
or 33 gallon drums.
Service à la clientèle
Canada: 888-645-2986
Please read and save these instructions. Read carefully before
attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing
all safety information. Failure to comply with instructions
could result in personal injury and/or property damage!
Retain instructions for future reference.
SPECIFICATIONS
Max. Weight Capacity 1000 Lbs.
Drum Type Lifted 33 gallon and 55 gallon closed-head
steel and poly drums
Net Weight 29 Lbs.
Overall Dimensions H= 8
1
/2", W= 28", D= 28"
1
WARNING:
1. Do not exceed the rated load,1000 Lbs.
2. Do not operate a damaged or malfunctioning unit
or a unit with missing parts.
3. Do not operate without having read and
understood the operating manual.
4. Do not leave suspended loads unattended.
5. Do not make alterations or modifications to lifter.
6.
Do not lift people or suspended loads over people.
7. Do not remove or obscure warning labels.
8. Stay clear of the suspended load.
9. Do not lift loads higher than necessary.
10. Do not use if top lip is damaged or deformed.
11. For safety and best results this product is
recommended to be used with a properly secured
drum lid. Use caution when using Drum lifter with
open drum.
052016
Open and Closed Head Drum Lifter
To adjust arms to different
settings, Remove cotter pins
and cylinder pins. Set arms to
the proper drum size.
User’s Manual
33 Gallon Setting
NOTE: Make sure arms
straddle over Drum before
lifting as shown.
Steel drum without lid
55 Gallon Setting
Before lifting drum
inspect the (3) Arms for
proper alignment.
Plastic drum without lid
2