Glastender BB60, BB84, ND52, ND72, ND92 Operation Manual

...
0 (0)
Glastender BB60, BB84, ND52, ND72, ND92 Operation Manual

Operation Manual, Parts Directory, and Price List

BB60, BB84, BB108, ND52, ND72, ND92,

BB60BW, BR, WR, BB84BW, BR, WR, BB108BW, BR, WR, ND52BW, BR, WR, ND72BW, BR, WR, ND92BW, BR, WR

2008 Energy Star Compliant Self-Contained BB and ND Coolers

BB and ND Two Zone Coolers

BB60-L1-XSH(LR)

BB60BR-L1-XS(LR)

ND72-R1-GS(LRL)

Glastender, Inc. · North Michigan Road · Saginaw, MI · 48604-9780 800.748.0423 · 989.752.4275 · Fax 989.752.4444 · www.glastender.com

Rev. 12-15-10

© 2009 Glastender, Inc.

Terms and Conditions

Prices:

All prices are LIST. Applicable taxes will be added.

Quotations:

Unless otherwise stated, quotations are effective for 30 days only.

Acceptance:

All orders are subject to acceptance by Glastender, Inc.’s headquarters in Saginaw, Michigan. Possession of the Product Directory and Price List is not an offer to sell.

Shipments:

F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or Collect if shipped directly to you. Prepay and Add to Invoice freight terms are available upon request. The approximate shipping weights of all products are listed with the prices. Partial shipments will be made unless otherwise specified by the customer. Surface freight classifications are:

Glasswashers, Line Chillers - Class 92.5 Cocktail Stations, Underbar Equipment - Class 85 Bar Die/Underbar Equipment – Class 125

Refrigeration Equipment, 48” long or smaller - Class 100 Refrigeration Equipment, greater than 48” long - Class 110

All small items are evaluated to see the most cost effective means for shipment. Many small items ship via UPS or FedEx; however, when dimensional weight is excessive DB Schenker, UPS Supply Chain, or even common LTL carriers are the most cost effective choice. Spare parts orders received before 1:00 PM EST can usually be shipped the same day.

The order department is happy to assist with routing or shipping questions.

Payment Terms:

Cash should be included with all orders unless credit terms have been arranged. To establish credit, banking and trade references are required. A convenient credit application is available upon request. Payment via credit card is not our normal means of receiving payment. Visa and MasterCard will be accepted, but must be charged at the time of shipment. In addition, a payment via credit card for orders totaling more than $500 will incur a 3% convenience fee on the total transaction amount.

Delivery:

The majority of equipment is manufactured to order and typically ships within three to six weeks after complete order information is received by the factory. In-stock equipment typically ships within two to three days of the factory receiving complete order information.

Returns:

Items specified as “Manufactured to Order” are NOT returnable.

A Return Material Authorization (RMA) number must be issued by the factory in advance for any items that are returnable. The RMA number MUST be noted on the outside of the returned package. Returns must be received within 90 days of the RMA issue date. Shipping charges must be prepaid. A minimum 20% restocking charge will be applied to all authorized returns if received in new, unused condition in the original packaging.

The above conditions apply to spare part returns, except spare part returns must be received within 30 days of original shipment for electronic or electrical parts or within 90 days for all other parts.

Loss or Damage:

For customer routed shipments, Glastender, Inc. is not responsible for any loss, damage, or delay of merchandise during shipment. Such transit claims must be filed with the carrier. Merchandise must be examined on arrival. If shortages occur, Glastender, Inc. must be notified in writing within five (5) days of delivery to honor any shortage claim. Glastender will assume responsibility for freight claims on Prepay and Add shipments but the customer must inspect freight and note any damage upon receipt. Failure to do so may result in losses at the customer’s expense.

Custom Orders:

Custom orders must be paid in advance and are not subject to cancellation.

Laminates:

Some products include common, readily available plastic laminates of the customer’s selection. There may be an additional charge if uncommon varieties are ordered.

05/18/10

Cooler Serial Number Information

This manual is specific to 2008 Energy Star compliant self-contained BB60, BB84, BB108, ND52, ND72, and ND92 coolers beginning with the serial numbers and dates listed below in addition to all BB and ND Two Zone Coolers.

 

 

 

 

 

 

 

 

BB60R

134121363F

02/26/09

 

 

ND52R

134121519F

03/09/09

BB60L

134121425F

03/03/09

 

 

ND52L

134121559F

03/11/09

BB84R

134121457F

03/04/09

 

 

 

 

 

 

 

ND72R

134121906F

04/08/09

BB84L

134121456F

03/04/09

 

 

ND72L

134121475F

03/11/09

BB108R

134121452F

03/04/09

 

 

ND92R

134121126F

02/09/09

BB108L

134121226F

02/17/09

 

 

ND92L

134122745F

06/10/09

 

 

 

 

 

 

 

 

1

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI

• 48604-9780

800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 •

www.glastender.com

Index

Service and Parts

 

Terms and Conditions.................................................

1

Warranty.....................................................................

11

Cooler Serial Number Information.............................

1

Digital Controller Operation.....................................

2

Installation

 

Introduction.................................................................

3

Utility Requirements and Connections.......................

3

Uncrating and Start-Up Instructions...........................

3

Operation.....................................................................

3

Cleaning Instructions..................................................

4

Sealing Vertical Door Cooler to Floor Instructions....

4

Cooler Installation Checklist......................................

5

Beer Tower Installation...............................................

5

Specifications

 

Electrical and Refrigeration Specifications.

............... 6

Wiring Diagrams.........................................................

6

Replacement Parts

 

Compressor and Condenser Related Parts..................

7

Evaporator and Related Parts......................................

8

Shelving, Racks and Related Parts.............................

8

Doors and Related Parts.........................................

9 - 10

Refrigeration Compartment Covers............................

9

220 Volt Electrical Parts...........................................

10

Electrical Components..............................................

10

Digital Controller Operation

The operating temperature range is preset at the factory according to the table below and can be adjusted up or down within the limits shown.

To see the set point - push and immediately release the SET button. The set point will be displayed.

To return to normal visualization - Push and immediately release the SET button or wait five seconds.

To change the set point - push and hold the SET button for more than two seconds. When the º F display begins flashing, push the up arrow or down arrow buttons to adjust the set point to the desired value.

To save the new set point and return to the temperature display mode - push and release the SET button or wait ten seconds.

 

Factory Settings

Range of Adjustment

 

 

 

 

 

 

Set Point

Operating Range†

Minimum Set Point

Maximum Set Point

 

 

 

 

 

Standard Cooler Setting

34º F

34º F to 39º F

33º F

35º F

Two Zone Cooler Settings*

 

 

 

 

 

 

 

 

 

B = Beer

34º F

34º F to 39º F

33º F

35º F

W = White Wine

50º F

50º F to 55º F

45º F

55º F

R = Red Wine

60º F

60º F to 65º F

55º F

65º F

Adjusting the factory set point will also adjust the operating range by the same amount

*To determine a Two Zone Cooler refrigeration configuration, refer to the 2 digits immediately preceding the first hyphen of the model number found on the cooler data tag. These 2 digits will always be BW (Beer/White Wine), BR (Beer/Red Wine), or WR (White Wine/Red Wine). Example: MODEL: BB60BR-L1-XS(LR).

The refrigerator is programmed to automatically defrost four times daily for approximately twenty minutes. During defrost, the fan inside the cooler will remain on and the refrigeration system will turn off. To initiate defrost manually, push and hold the DEFROST button for more than two seconds.

The thermostat controller does not have an “OFF” function. To turn refrigerator off, the unit must be unplugged or power to the electrical branch circuit has to be turned off via a circuit breaker or switch.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI

• 48604-9780

2

800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 •

www.glastender.com

Installation

Introduction

This manual describes the operational features of self-contained BB60, BB84, BB108, ND52, ND72, and ND92 coolers and two zone coolers. Please review this information before attempting installation and operation.

Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for selecting Glastender, Inc. products.

Utility Requirements and Connections

Electrical: 115 Volt AC, 1 Phase, 60 Hz. A separate 15 Amp circuit is recommended. A 6-foot grounded cord and plug is included with self-contained models.

Plumbing: Automatic condensate evaporator is included. No drain connection required.

Uncrating and Start-Up Instructions

All models are shipped in one carton. These steps should be followed:

1.If legs or casters are included, bolt them to the base with the bolts provided.

2.Unwrap power cord from base if included.

3.Position unit and level and/or seal as required (see page 4 and 5).

4.All units intended for draft beer must be plumbed to an external drain. On self-contained models with draft beer and a factory installed finished top, the beer tower drain pan is plumbed through the cabinet and stubs out in the 3" space below the compressor compartment. Connection to an external drain must be made from that point.

5.Place shelves in desired location.

6.Plug into 115 volt AC outlet.

7.Load with bottles or cans and allow time for products to cool.

8.Your Glastender equipment is now ready for use.

Operation

The operating temperature range is 34°F (1°C) to 40°F (5°C).

Self-contained models include an automatic defrost system. The refrigerator will defrost four times daily for approximately 20 minutes. During the defrost, the fan inside the cooler will remain on and the refrigeration system will turn off.

3

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI

• 48604-9780

800.748.0423 • 989.752.4275 • Fax 800.838.0888 / 989.752.4444 •

www.glastender.com