Geovision GV-Relay V2 User Manual

GV-Relay V2
The GV-Relay V2 is designed especially for driving higher voltage output devices, and it is controlled by other GV devices, such as GV-Video Server, GV-Compact DVR, GV-IP Camera, GV-DSP LPR, GV-I/O USB Box and GV-NET/IO Card V3.1.
The GV-Relay V2 provides 4 relay outputs, and each output can be set as normally open (NO) or normally closed (NC) independently as per your requ irement.
Note: The difference between GV-Relay V1 and GV-Relay V2: GV-Relay V1 must work with GV-IO Box together, while GV-Relay V2 must work with GV IP devices, GV-I/O USB Box or GV-NET/IO Card V3.1.
Packing List
1. GV-Relay V2 Box x 1
Specifications
Relay Output Relay Status Relay Capacitance
RL1 - RL4 Normally Open and Normally Closed for each output 10A 250V AC, 10A 125V AC, 5A 100V DC
Connections
1. Connecting to GV-Video Server, GV-DSP LPR
The outputs of GV-Video Server / GV-DSP LPR can only drive a maximum load of 5V. After connecting to GV-Relay V2, they can drive heavier loads.
Output Devices 1-4
24681012 14 16
13579111315
GV-Relay V2
DO 1 DO 2 DO 3 DO 4
+ 5V
Note: You don’t need to use the DC 5V connector on the GV-Relay V2 for power supply, since the power is supplied from the GV-Video Server or GV-DSP LPR.
2. Connecting to GV-Compact DVR
The outputs of GV-Compact DVR can only drive a maximum load of 5V. After connecting to GV-Relay V2, they can drive heavier loads.
GV-Video
Server
Pin 1 Pin 3 Pin 5 Pin 7 Pin 9
Relay On/Off Time Relay Control Source
Dimensions
8ms / 5ms +5V, COM, DO1 - DO4 Connecting Outputs of GV-Video Server / GV-Compact DVR / GV-IP Camera / GV-DSP LPR / GV-I/O USB Box / GV-NET/IO Card V3.1
120 (W) x 26 (H) x 93 (D) mm
Output Devices 1-4
Connect to Power
24681012 14 16
13579111315
GV-Relay V2
DO 1 DO 2 DO 3 DO 4 COM
GV-Compact
DVR
Pin 1 Pin 3 Pin 5 Pin 7
Pin 9 or 11
3. Connecting to GV-IP Camera
The outputs of GV-IP Camera can only drive a maximum load of 5V. After connecting to GV-Relay V2, they can drive heavier loads.
Output Devices 1-4
5. Connecting to GV-I/O USB Box
When GV-I/O USB Box is connected to PC with the USB cable, it can only drive a maximum of 30 V DC. After connecting to GV-Relay V2 Box, it can drive heavier loads.
GV-Relay V2
DO 1 COM
GV-IP Camera
Pin 1 Pin 2
1234
Connect to Power
4. Connecting to GV-NET/IO Card V3.1
When GV-NET/IO Card V3.1 is set to I/O Box mode and connected to PC with the USB cable, it is allowed only for DC output voltage. After connecting to GV­Relay V2, it can drive heavier loads.
Output Devices 1-4
ON
1ON
1 2ON1
Relay Out 1 Relay Out 2 Relay Out 3 Relay Out 4 COM
Output Devices 1-4
Connect to Power
GV-Relay V2
DO 1 DO 2 DO 3 DO 4 COM
Output
COM.H Com Output 16 Output 15 Output 14 Output 13 Com Output 12 Output 11 Output 10 Output 9 Com Output 8 Output 7 Output 6 Output 5
Com Output 4 Output 3 Output 2 Output 1
RS-485 +
RS-485 -
DO 16
DO 15
DO 14
DO 13
COM.G
DO 12
DO 11
DO 10
DO 9
COM.F
DO 8
DO 7
DO 6
DO 5
COM.E
DO 4
DO 3
DO 2
DO 1
RS- 485 R X RX- 485 T X
DC 12V
H
G
F
E
GV-I/O USB
DO1 / DO 5 / DO 9 / DO 13 DO2 / DO 6 / DO 10 / DO 14 DO3 / DO 7 / DO 11 / DO 15 DO4 / DO 8 / DO 12 / DO 16
COM
GV-IO
Input
USB RX USB TX
COM.D
Com
DI 16
Input 16
DI 15
D
C
B
A
COM.C
COM.B
COM.A
Input 15
DI 14
Input 14
DI 13
Input 13 Com
DI 12
Input 12
DI 11
Input 11
DI 10
Input 10
DI 9
Input 9 Com
DI 8
Input 8
DI 7
Input 7
DI 6
Input 6
DI 5
Input 5 Com
DI 4
Input 4
DI 3
Input 3
DI 2
Input 2
DI 1
Input 1
Connect to Power
GV-Relay V2
DO 1 DO 2 DO 3 DO 4 COM
GV-NET I/O Card
Relay Out 1 Relay Out 2 Relay Out 3 Relay Out 4
COM
2008.03.24
Loading...