SPLIT TYPE ROOM AIR
CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASH9FSB
ASH12FSBCW AOH12FSBC
CW
AOH9FSB
C
CONTENTS
. . . . . . . .
. . . . . .
. . . . . .
. . .
. . . . . .
. . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . .
. . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . .
. . . . . . . .
. . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . .
. . .
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1
OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . 3
REFRIGERANT SYSTEM DIAGRAM . . . . . . . . 4
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 5
INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM
ERROR DISPLAY
DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . .
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
STANDARD ACCESSORIES . . . . . . . . . . . . . . . .14
6
7
8
S P E C I F I C A T I O N S
TYPE
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY
(kW)
COOLING COOLING
ASH9FSBCW ASH12FSBCW
AOH9FSBC AOH12FSBC
2.75 3.40
ELECTRICAL DATA
POWER SOURCE
RUNNING CURRENT (A)
INPUT WATTS (kW)
E.E.R (kW/kW)
MOISTURE REMOVAL
AIR CIRCULATION-Hi
3
(m /hr) 540 540
230V 50Hz 230V 50Hz
4.7 6.2
1.05 1.33
2.62 2.56
1.3 1.8
COMPRESSOR
TYPE
CODE
REFRIGERANT R410A
(g)
Hermetic type, Permanent split condenser, 2 pole, Single phase, Induction motor
80230135 220, 230, 240V / 50Hz 80235035 220-240V / 50Hz
590 720
FAN MOTOR
POWER SUPPLY (V) 230 230
INDOOR
UNIT
Hi-SPEED (r.p.m) 1,310
MED-SPEED (r.p.m) 1,190
LO-SPEED (r.p.m) 1,070
S-LO (r.p.m) 960
1,310
1,230
1,150
1,080
OUTDOOR UNIT (r.p.m) 740 740
DIMENSIONS
INDOOR UNIT
OUTDOOR UNIT
H x W x D
(mm)
WEIGHT
INDOOR UNIT
OUTDOOR UNIT
GROSS
NET(kg)
NOISE LEVEL
Hi-SPEED (dB) 39 39
INDOOR
UNIT
MED-SPEED (dB) 37
LO-SPEED (dB)
S-LO (dB)
OUTDOOR UNIT (dB)
257 x 808 x 187 257 x 808 x 187
535 x 695 x 250 535 x 695 x 250
10 / 8 10 / 8
33 / 30 35 / 32
37
34 35
31
33
45 46
12003.10.30
ADDITIONAL CHARGE OF REFRIGERANT
(ASH9FSBCW / AOH9FSBC)
(ASH12FSBCW / AOH12FSBC)
Refrigerant suitable for a piping length of 7.5 m is charged in the outdoor unit at the factory.
When the piping is longer than 7.5 m, additional charging is necessary.
For the additional amount, see the table below.
PIPE LENGTH 7.5 m 10 m
ADDITIONAL REFRIGERANT None 50 g
Between 7.5 m and 10 m, when using a connection pipe other than that in the table,
charge additional refrigerant with 20g /1 m as the criteria.
(The maximum length of piping is 15m. If the units are further apart than this, correct
operation can not be guaranteed.)
15 m
150 g
2003.10.30 2
REFRIGERANT SYSTEM DIAGRAM
Models : ASH9FSBCW / AOH9FSBC
[ INDOOR UNIT ]
[ Connecting pipe ]
[ OUTDOOR UNIT ]
ComĀpressor
(Flare connection)
Gas pipe (9.52 dia.)
(Flare connection)
3-Way valve
(with charging port)
Condenser
Evaporator
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
2-Way valve
Dryer
Capillary tube
Models : ASH12FSBCW / AOH12FSBC
[ INDOOR UNIT ]
[ Connecting pipe ]
(Flare connection)
Gas pipe (9.52 dia.)
(Flare connection)
[ OUTDOOR UNIT ]
3-Way valve
(with charging port)
ComĀpressor
Condenser
Evaporator
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
2-Way valve
Dryer
Capillary tube
2003.10.30 4