KEEP THIS MANUAL FOR FUTURE REFERENCE
DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN
CONSERVEZ CE MODE D’EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT
GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO
ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙ∆ΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR
СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
● Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
● The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
● “DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
DANGER!
WARNING!
CAUTION!
DANGER!
This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
● Do not attempt to install this air conditioner by yourself.
● This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
● When moving, consult authorized service personnel for disconnection and installation of the unit.
● Do not become excessively chilled by staying for lengthy periods in the direct cooling
airflow.
● Do not insert fingers or objects into the outlet port or intake grilles.
● Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
● Take care not to damage the power supply cord.
● In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the circuit breaker, and consult authorized service personnel.
● If the power supply cord of this appliance is damaged, it should only be replaced by
the authorized service personnel, since special purpose tools and specified cord are
required.
En-1
CAUTION!
● Provide occasional ventilation during use.
● Do not direct air flow at fireplaces or heating apparatus.
● Do not climb on, or place objects on, the air conditioner.
● Do not hang objects from the indoor unit.
● Do not set flower vases or water containers on top of air conditioners.
● Do not expose the air conditioner directly to water.
● Do not operate the air conditioner with wet hands.
● Do not pull power supply cord.
● Turn off power source when not using the unit for extended periods.
● Check the condition of the installation stand for damage.
● Do not place animals or plants in the direct path of the air flow.
● Do not drink the water drained from the air conditioner.
● Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
*● Connection valves become hot during Heating; handle with care.
● Do not apply any heavy pressure to radiator fins.
● Operate only with air filters installed.
● Do not block or cover the intake grille and outlet port.
● Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
● Avoid installing the air conditioner near a fireplace or other heating apparatus.
● When installing the indoor and outdoor units, take precautions to prevent access by
infants.
● Do not use inflammable gases near the air conditioner.
FEATURES AND FUNCTIONS
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
AUTO CHANGEOVER
[HEAT & COOL MODEL (Reverse Cycle)]
The operation mode (cooling, dry, heating) is switched
automatically to maintain the set temperature, and the
temperature is kept constant at all times.
AUTOMATIC OPERATION [COOLING MODEL]
Merely press the START/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the
actual temperature of the room.
SLEEP TIMER
*● HEAT & COOL MODEL (REVERSE CYCLE)
When the SLEEP timer button is pressed during Heating
mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during Cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached,
the unit automatically turns off.
● COOLING MODEL
When the SLEEP timer button is pressed during Cooling
mode, the thermostat setting is gradually raised during
the period of operation. When the set time is reached,
the unit automatically turns off.
SWING OPERATION
The Air Flow Direction Louvers swings automatically up and
down so that the air speeds to every nook and corner of
your room.
REMOVABLE INTAKE GRILLE
The indoor unit’s INTAKE GRILLE can be removed for easy
cleaning and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth,
thus allowing cleaner use and easier care.
SUPER QUIET OPERATION
When the FAN CONTROL button is used to select QUIET,
the unit begins super-quiet operation; the indoor unit’s airflow is reduced for quieter operation.
AIR CLEANING FILTER (Optional)
The optional Air Cleaning Filter (Model APS-03B) uses an
electrostatic principle to clean the air of fine particulate
matter such as tobacco smoke and plant pollen.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient
control of air conditioner operation.
En-2
NAME OF PARTS
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Fig. 1
~
9
0
-
3
=
1
Fig. 2
4
Fig. 3
8
Fig. 4
OPERATION
TIMER
SWING
2
5
6
7
$
£
* HEAT & COOL MODEL (REVERSE CYCLE)
∞•¢¶
@
(
#
_
!
)
™
%
^
Fig. 5
This figure shows the control display when all indicator lamps are on. It may differ from the actual display.
+
¡
*
&
§
COOLING MODEL
Fig. 6
En-3
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2)
2 MANUAL AUTO button
the timer is operating, it indicates that a
fault has occurred with the timer setting
(See Page 15 Auto Restart).
7 SWING Indicator Lamp (orange)
8 Intake Grille (Fig. 4)
9 Air Filter
0 Air Flow Direction Louver
A Right-Left Louver
(behind Air Flow Direction Louver)
B Drain Hose
C Air Cleaning Filter (optional)
Fig. 5 Remote Control Unit
D SLEEP button
E MASTER CONTROL button
F SET TEMP. button (
/ )
G Signal Transmitter
H OFF TIMER button
I ON TIMER button
J SET TIMER button
K CANCEL TIMER button
L FAN CONTROL button
M START/STOP button
N AIR FLOW DIRECTION button
O SWING LOUVER button
P ACL button
Q TEST RUN button
● This button is used when installing the
conditioner, and should not be used under normal conditions, as it will cause the
air conditioner’s thermostat function to operate incorrectly.
● If this button is pressed during normal operation, the unit will switch to test operation mode, and the Indoor Unit’s OPERATION Indicator Lamp and TIMER Indicator
Lamp will begin to flash simultaneously.
● To stop the test operation mode, press the
START/STOP button to stop the air conditioner.
R Remote Control Unit Display (Fig. 6)
S Transmit Indicator
T Operating Mode Display
U Timer Mode Display
OFF TIMER Mark:
ON TIMER Mark:
SLEEP TIMER Mark:
V Fan Speed Display
W Temperature and time display
It displays the temperature setting. However,
when making the Timer setting, it will display
the Timer time. (The temperature setting will
reappear after finishing the timer setting)
En-4
PREPARATION
Turn on the Power
Turn on the circuit breaker.
Load Batteries (R03/LR03
××
× 2)
××
Press and slide the battery compartment lid on the re-
1
verse side to open it.
Slide in the direction of the arrow while pressing the mark.
Insert batteries.
2
Be sure to align the battery polarities () correctly.
Close the battery compartment lid.
3
To Use the Remote Control Unit
● The Remote Control Unit must be pointed at signal receiver (Fig. 1 3) to operate
correctly.
● Operating Range: About 7 meters.
● When a signal is properly received by the air conditioner, a beeping sound will
be heard.
● If no beep is heard, press the Remote Control Unit button again.
CAUTION!
● Take care to prevent infants from
accidentally swallowing batteries.
● When not using the remote control unit
for an extended period, remove the
batteries to avoid possible leakage and
damage to the unit.
● If leaking battery fluid comes in contact
with your skin, eyes, or mouth, immediately wash with copious amounts of
water, and consult your physician.
● Dead batteries should be removed
immediately and disposed of properly,
either in a battery collection receptacle
or to the appropriate authority.
● Do not attempt to recharge dry batteries.
Never mix new and used batteries, or
batteries of different types.
Batteries should last about one year
under normal use. If the remote control
unit’s operating range becomes appreciably reduced, replace the batteries and
press the ACL button with the tip of a
ballpoint pen or other small object.
INSTALLATION OF REMOTE CONTROL UNIT HOLDER
Please attach a holder like the following explanation.
Slide up
Insert
Screws
1 Mount the Holder.2 Set the Remote
Press in
Control Unit.
Pull out
3 To remove the
Remote Control Unit
(when use at hand).
En-5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.