The control box is easily accessible for maintenance work
Wide opening for easy access.
CASSETTE TYPE
AU24
Detachable,washable filter and intake grille.
Wide opening and long-life filter.
Long-life filter
High efficiency, long-life filter extends the cleaning cycle.
CASSETTE TYPE
AU24
Slim intake grille
Slim type intake grille can fit the ceiling after installation.
20
(unit: mm)
Group controller
One remote controller can control up to 16 air conditioners.
All of the air conditioners will be operated with the same settings.
Long-life filter
Connectable quantity : Maximum 16 indoor units for 1 remote controller.
- (03 - 01) -
Duct connection hole opening
Fresh air can be introduced through this opening.
Distribution
duct
CASSETTE TYPE
AU24
Fresh air
CASSETTE TYPE
AU24
Distribution
duct
Conditioned air can be distributed by means of a distribution duct.
Two-way
One-way
- (03 - 02) -
3-2. REMOTE CONTROLLER
3-2-1. WIRED REMOTE CONTROLLER
FEATURES
Various timer setup (ON / OFF / WEEKLY) are possible.
SUMOTUWETH FR SA
7
3126 9
15 18 21
CASSETTE TYPE
AU24
High performance and compact size
Equipped with weekly timer as standard function.
(2 times Start / Stop per day for a week)
When setting up a timer, operation mode and a temperature
setup can be changed.
When a failure occurs,the error code is displayed. (Maximum of 16)
Error indication.(A maximum of 16 error histories are memorizable.)
Up to 16 indoor units can be simultaneously controlled.
Anti freeze and energy saving operation are possible.
Easy installation with a slim shape with no boldge in the back.
The room temperature can be controlled by being detected the temperature
accurately with built-in thermo sensor.
CASSETTE TYPE
AU24
Three functions are combined in
one unit.
Wired
remote
controller
Built-in timers
Possible to set ON/OFF time to operate twice each day
of the week.
SUMOTUWETH FR SA
7
3126 9
15 18 21
Setup screen example
(Set to Wednesday: 8:00 to 20:00.)
0 3 6 9 12 15 18 21 Time
At "Weekly timer" + "Set back timer" setup
Easy-to-understand time bar display
24°C
SUMOTUWETH FR SA
7
3126 9
15 18 21
Screen
after setup
24°C 28°C 24°C
Weekly
timer
Setback
timer
Setback timerWeekly timer
Possible to set temperature for two time spans and
for each day of the week.
SUMOTUWETH FR SA
3126 9
15 18 21
Setup screen example
(Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
28°C
0 3 6 9 12 15 18 21 Time
24°C
0 3 6 9 12 15 18 21 Time
28°C
Easy-to-understand operationSimple installation
Components are compatible with standard
switch boxes. Flat back construction allows
equipment to be installed wherever it is
needed.
Timer
area
[
Variable timer control
]
The operation/display sections are zoned according to time and operation, enabling variable programming to match application.
Operation
area
European
switch box
- (03 - 03) -
JIS box
FUNCTIONS
1
START/STOP button
Pressed to start and stop operation.
2
Display
SUMOTUWETH FR
SA
369
12 15 18 21
2
7
8
9
10
11
CASSETTE TYPE
AU24
12
CLOCK ADJUST
SET BACK
DELETESET
DAY
DAY OFF
ENERGY
SAVE
THERMO
SENSOR
14
1
3
4
5
6
13
Display panel
15
16
1718 19
Set Temperature button
Selects the setting temperature.
3
Master control button
Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY).
4
Fan control button
Selects the fan speed (AUTO, LOW, MED, HIGH).
5
Thermo sensor button
6
Energy save button
Turns the energy efficient mode on and off.
7
Timer mode (CLOCK ADJUST) button
Selects the timer mode (OFF TIMER, ON TIMER,
WEEKLY TIMER) Set the current time.
8
Day (DAY OFF) button
Temporarily cancels of one day timer.
9
Set back button
pressed select the set back timer.
CASSETTE TYPE
AU24
SUMOTUWETH FR
369
DIMENSION
120
SUMOTUWETH FR
CLOCK ADJUST
SET BACK
DELETESET
SA
369
12 15 18 21
DAY
DAY OFF
Front View
12 15 18 21
ENERGY
SAVE
SA
THERMO
SENSOR
202122
[ Unit : mm ]
120
10
Set time button
Pessed to select the set back timer.
11
Delete button
The schedule of a weekly timer is deleted.
12
Set button
Sets the date, hour, minute and on-off time.
13
Vertical air flow direction and swing button
Push for two seconds to change the swing mode
14
17
Operation lamp
Lights during operation and when the timer is on.
15
Timer and clock display
16
Operation mode display
17
Fan speed display
18
Central control display
19
Temperature display
20
Stand by display
Indicates during the oil recovery and defrosting operation.
21
Vertical swing display
22
Energy save display
SPECIFICATION
SIZE (H x W x D mm)120 x 120 x 17
WEIGHT( g )160
CABLE LENGTH( m )
POWER( V )
10
12
- (03 - 04) -
3-3. SPECIFICATIONS
Fin Pitch
Fin Pitch
INDOOR
FAN SPEED
COOL/HEAT
46/46
44/44
39/39
52/54
Turbo × 1
Propeller × 1
40
65
Aluminium
2 × 30
630 × 901 × 36.38
1300
Copper tube
Copper tube
AVAILABLE VOLTAGE RANGE
198-264V 50Hz
C
EUROPEAN ENERGY LABEL
743 × 984 × 413
355 × 1060 × 1025
Inverter
White (5Y9/0.5NN)
Beige(10YR7.5/1.0NN)
2 × 10
210 × 970 × 26.6
1.45
Aluminium
1.30
34/44(75/97)
54/58(119/128)
1800
15.88(5/8inc)
25(chargeless: 10)
FLARE
9.52(3/8inc)
10.5/13.0102.81
3.25
246 × 830 × 830
650 × 830 × 320
7.10/8.00
24200/27300
7.80/9.00
26600/30700
2.0(4.2)
2.53/2.98
2.40/2.98
11.1/13.0
REMOTE CONTROLLER
Wired
ABS
DRAIN PIPE
MATERIAL
SIZE
Outer diameter 37.0/Inner diameter 32.0
DIMENSIONS
H × W × D
mm
MAX LENGTH
SIZE
mm
kg(lbs)
WEIGHT
CONNECTION METHOD
NET
GROSS
POE
15
TYPE
R410A
TYPE
MAX HEIGHT
REFRIGERANT OIL
REFRIGERANT
PIPE
NET / GROSS
kW
INPUT POWER
COOLING
HEATING
CURRENT
dB(A)
STARTING CURRENT
MOISTURE REMOVAL
kW/kW
INVERTER HEAT PUMP TYPE
CASSETTE MODELS
TYPE
230V 50Hz
RATED / MAX
INDOOR
OUTDOOR
POWER SOURCE
MODEL NAME
CAPACITY
RATED / MAX
AU 24LUAR
AO 24LMAKL
A
NOISE LEVEL
(SOUND
PRESSURE)
COOL/HEAT
INDOOR
AIR
CIRCULATION
COOL/HEAT
m
3
/h
EER
COP
FAN MOTOR OUTPUT
W
INDOOR
1250/1250
1080/1080
920/920
3200/3200
Coil
OUTDOOR
r.p.m
400/400
-
540/490
480/430
390/340
OUTPUT
780/780
HEAT
EXCHANGER
TYPE
FAN TYPE x Q'ty
OUTDOOR
Coil
Fin
Fin
mm
COMPRESSOR
OUTDOOR
INDOOR
OUTDOOR
Hermetic type, 4 poles, DC motor, TWIN ROTARY
Rows x Stages
mm
Rows x Stages
TYPE
STARTING METHOD
INDOOR
CASING COLOR
COOLINGRATED / MAX
HEATINGRATED / MAX
COOLINGRATED / MAX
HEATINGRATED / MAX
COOLING
CASSETTE TYPE
AU24
OUTDOORHigh
HEATING
Quiet
INDOOR
OUTDOOR
INDOOR
OUTDOOR
High
Med
Low
High
Med
Low
High
Low
High
Med
Low
COOLING
kW
BTU/h
kW
BTU/h
A
l/h(pints/h)
CASSETTE TYPE
AU24
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
W
Coil Dimensions
Coil Dimensions
LIQUID
GAS
m
m
CHARGEg
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB.
Heating:Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
mm
- (03 - 05) -
3-4. DIMENSIONS
3-4-1. OUTDOOR UNIT
MODEL : AO 24L
(Unit : mm)
Top view
830
CASSETTE TYPE
AU24
650
12
Front view
Bottom
Air flow
350
320
Side view
CASSETTE TYPE
AU24
154
101
58
90
MOUNTING POSITION
When there are obstacles at the
back or front sides.
100 mm
or more
600 mm
or more
Bottom view
100 mm
or more
343
603
When there are obstacles at the
back, side(s), and top.
600 mm or more
300 mm
25
(
S
0 mm o
er
v
i
c
r
more
e s
p
ac
e)
or more
When there are obstacles at the
back, side with the installation of
more than one unit.
250 mm
or more
250 mm
or more
300 mm
or more
- (03 - 06) -
3-4-2. INDOOR UNIT
750
830
750
830
Bottom view
MODEL : AU 24L
CASSETTE TYPE
AU24
940
(Unit : mm)
246
30
Side view
CASSETTE TYPE
AU24
940
Bottom view (Panel)
Drain insideDia. 32
outside Dia. 37
235
Side view (Standard setting)
60
(Drain pipe)
200
305.5
Side view (Slender setting)
298.5
248.5
100
70
(Small pipe)
(Large pipe)
- (03 - 07) -
MOUNTING POSITION
Floor
Strong and durable ceiling
CASSETTE TYPE
AU24
2,300 mm
or more
1,200 mm
or more
1,000 mm
or more
CASSETTE TYPE
AU24
Obstruction
You can select 2-way setting
(A) Standard setting(B) Slender setting
215 mm
250 mm
or more
100 or more100 or more
or more
100 or more
(4 directions)(3 directions)
Piping position
(2 directions)(2 directions)
100 or more
- (03 - 08) -
3-5. REFRIGERANT CIRCUIT
MODELS : AU 24L / AO 24L
CASSETTE TYPE
AU24
Ø15.88mm(5/8")
CASSETTE TYPE
AU24
Ø9.52mm(3/8")
- (03 - 09) -