AS 9FMBD, AS 9UMBD
AS 12FMBD, AS 12UMBD
AU 12FMAB, AU 12UMAB
D2D_MU002E/01
2006.04.12
3-1. FEATURE
AO 19FSCV2AS 9FMBDAS 9FMBD
AS 12FMBDAS 7FMBD
AS 7FMBDAU 12FMAB
AS 12FMBDAS 12FMBD
AS 12FMBDAU 12FMAB
AU 12FMABAU 12FMAB
AO 19USCV2AS 9UMBDAS 9UMBD
AS 12UMBDAS 7UMBD
AS 7UMBDAU 12UMAB
AS 12UMBDAS 12UMBD
AS 12UMBDAU 12UMAB
AU 12UMABAU 12UMAB
INDOOR UNIT
AO 20FSBV2
AO 24FSBV2
AO 20USBV2
AO 24USBV2
H
E
A
T
P
U
M
P
T
Y
P
E
C
O
O
L
I
N
G
O
N
L
Y
T
Y
P
E
OUTDOOR UNIT
MODELS :
WALL MOUNTED INDOOR UNIT
AS 7FMBD, AS 7UMBD
AS 9FMBD, AS 9UMBD
AS 12FMBD, AS 12UMBD
CASSETTE INDOOR UNIT
AU 12FMAB, AU 12UMAB
OUTDOOR UNIT
MULTI TYPE
2ROOM TYPE
MULTI TYPE
2ROOM TYPE
AO 20FSBV2, AO 20USBV2
AO 24FSBV2, AO 24USBV2
COMBINATIONS
UNIT AUNIT B
AO 19FSCV2, AO 19USCV2
- (03 - 01) -
3-1-1. WALL MOUNTED TYPE
FEATURES
Symmetrical design
Symmetrical, clean design that suits all interiors.
Auto swing louvre
The Auto Swing Louvre function ensures that the
air direction corresponds to the mode selected.
Compact size
Powerful output in spite of small size
Though the indoor unit is compact, it features a large, high
pressure cross fan (90mm diameter) in a centre mounted
configuration and a Lambda type heat exchanger to provide
plenty of power.
MULTI TYPE
2ROOM TYPE
Unit: mm
Height257
Width808
Depth187
Cooling : 3-step ( - )
Heating : 6-step ( - )
Step
Swing
*1 : Heating only
Swing
Swing
*1
MULTI TYPE
2ROOM TYPE
Washable open panel
Cleaning the washable panel
removes mould and dust.
A regular wipe with a dry cloth
keeps the casing clean.
Since the panel is removed and
easily washed, it is always
clean. Filter cleaning is also
simple.
- (03 - 02) -
3-1-2. CASSETTE TYPE
FEATURES
Compact size
Compact grille fits European ceiling panel (650 x 650 mm).
Punch Hall grille
MULTI TYPE
2ROOM TYPE
650
MULTI TYPE
2ROOM TYPE
650
(unit: mm)
Slim intake grille
Slim type intake grille can fit the ceiling after installation.
20
(unit: mm)
Detachable,washable filter and intake grille.
Intake grille and air filter can be removed easily and cleaned.
Long-life filter
- (03 - 03) -
Duct connection hole opening
Fresh air can be introduced through this opening.
Fresh air
MULTI TYPE
2ROOM TYPE
MULTI TYPE
2ROOM TYPE
Distribution
duct
Distribution
duct
Conditioned air can be distributed by means of a distribution duct.
Three kinds of timer setup (ON / OFF / SLEEP) are possible.
Three kinds of timers. Easy operation.
MULTI TYPE
2ROOM TYPE
Built-in timers
Select from three different timer programs (On/Off/Sleep).
Sleep timer
MULTI TYPE
2ROOM TYPE
The sleep timer function automatically corrects the temperature thermostat setting according to the
time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
1 °C
2 °C
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The
set temperature can drop to a maximum of 4 °C.
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Four kinds of timers. Easy operation.
Easy to change transmission code (4 patterns) by button operation.
MULTI TYPE
2ROOM TYPE
Built-in timers
Select from four different timer programs (On/Off/Program/Sleep).
Program timer
The program timer operates the ON and OFF timer once within a 24 hour period.
Sleep timer
MULTI TYPE
2ROOM TYPE
The sleep timer function automatically corrects the temperature thermostat setting according to the
time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
1 °C
2 °C
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The
set temperature can drop to a maximum of 4 °C.
1 °C
2 °C
3 °C
4 °C
30min.
60min.
90min.
Timer setting
Simultaneously operation
After code change
Mixed-up
• Code selector switch eliminates unit
being wrongly switched.
(Up to 4 codes can be set.)
ABCD
AB
C
D
•Wide and precise
transmitting range.
1. Press the MASTER CONTROL
button for more than five seconds
to start the code change.
2. Press the (+) or (-) button to
select the desired code.
A B C D
3. Press the MASTER CONTROL
button again to end the code
change.
SPECIFICATION
SIZE (H x W x D mm)158 x 56 x 20
WEIGHT ( g )70
ACCESSORYHolder
- (03 - 06) -
3-3. SPECIFICATIONS
COMP.A
COMP.B
UNIT B
UNIT A
AS 9FMBD (UNIT : A/B)AS 9FMBD (UNIT : A)AS 9FMBD (UNIT : B)
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27°CDB / 19°CWB,and outdoor temperature of 35°CDB/24°CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
COOLING°C
mm
- (03 - 07) -
COMP.A
COMP.B
UNIT B
UNIT A
1 ROOM RATED
AS 9UMBD (UNIT : A/B)AS 9UMBD (UNIT : A)AS 9UMBD (UNIT : B)
White (10Y8.5/0.5NN)White (10Y8.5/0.5NN)W hite (10Y8.5/0.5NN)
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27°CDB / 19°CWB,and outdoor temperature of 35°CDB/24°CWB.
Heating:Indoor temperature of 20°CDB / 15°CWB,and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
mm
- (03 - 08) -
COMP.A
COMP.B
UNIT B
UNIT A
AS 12FMBD (UNIT : A) AU 12FMAB (UNIT : A) AS 7FMBD (UNIT : B) AS 12FMBD (UNIT : A)AS 7FMBD (UNIT : B) AU 12FMAB (UNIT : A) AS 7FMBD (UNIT : B)
WALL MOUNTED MODEL CASSETTE MODEL WALL MOUNTED MODEL WALL MOUNTED MODEL WALL MOUNTED MODELCASSETTE MODEL WALL MOUNTED MODEL
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27°CDB / 19°CWB,and outdoor temperature of 35°CDB/24°CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
White (10Y8.5/0.5NN)White (5Y9/0.5NN)White (10Y8.5/0.5NN) White (10Y8.5/0.5NN) White (10Y8.5/0.5NN)White (5Y9/0.5NN)White (10Y8.5/0.5NN)
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27DB / 19°CW B,and outdoor temperature of 35°CDB/24°CWB.
Heating:Indoor temperature of 20°CDB / 15°CWB,and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
White (10Y8.5/0.5NN)White (5Y9/0.5NN)White (10Y8.5/0.5NN)White (10Y8.5/0.5NN)White (10Y8.5/0.5NN) White (5Y9/0.5NN)White (10Y8.5/0.5NN)
AS 12FMBD (UNIT : A/B) AU 12FMAB (UNIT : A/B) AS 12FMBD (UNIT : A/B) AS 12FMBD (UNIT : A/B) AU 12FMAB (UNIT : A/B) AU 12FMAB (UNIT : A/B) AS 12FMBD (UNIT : A/B) AU 12FMAB (UNIT : A/B)
WALL MOUNTED MODELCASSETTE MODELWALL MOUNTED MODEL WALL MOUNT ED MODEL CASSETTE MODEL CASSETTE MODEL WALL MOUNTED MODEL
CASSETTE MODEL
Fin Pitch1.31.41.3 1.3 1.4 1.4 1.3 1.4
Fin Pitch
White (10Y8.5/0.5NN) White (10Y8.5/0.5NN)White (5Y9/0.5NN) White (5Y9/0.5NN)White (10Y8.5/0.5NN) White (5Y9/0.5NN)
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27°CDB / 19°CW B,and outdoor temperature of 35°CDB/24°CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
AS 12UMBD (UNIT : A/B) AU 12UMAB (UNIT : A/B) AS 12UMBD (UNIT : A/B) AS 12UMBD (UNIT : A/B) AU 12UMAB (UNIT : A/B) AU 12UMAB (UNIT : A/B) AS 12UMBD (UNIT : A/B) AU 12UMAB (UNIT : A/B)
WALL MOUNTED MODELCASSETTE MODELWALL MOUNTED MODEL W ALL MOUNTED MODEL CASSETTE MODELSCASSETTE MODELSW ALL MOUNTED CASSETTE MODELS
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27°CDB / 19°CWB,and outdoor temperature of 35°CDB/24°CW B.
Heating:Indoor temperature of 20°CDB / 15°CWB,and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
White (10Y8.5/0.5NN)White (5Y9/0.5NN)W hite (10Y8.5/0.5NN) White (10Y8.5/0.5NN)White (5Y9/0.5NN) W hite (5Y9/0.5NN)W hite (10Y8.5/0.5NN) White (5Y9/0.5NN)